OSEM-3D reconstruction strategies for the ECAT HRRT

被引:0
|
作者
Comtat, C [1 ]
Bataille, F [1 ]
Michel, C [1 ]
Jones, JP [1 ]
Sibomana, M [1 ]
Janeiro, L [1 ]
Trébossen, R [1 ]
机构
[1] CEA, Frederic Joliot Hosp Facil, SHFJ, Orsay, France
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
High spatial resolution dynamic brain PET imaging with the ECAT HRRT scanner with short frame durations is characterized by very few counts per sinogram bin due to the small size of the crystal surface. The use of various weighting schemes for OSEM-3D can result in significantly different results. In particular, the correction for random and scattered coincidences prior to the reconstruction can lead to a systematic positive bias in the reconstructed image. We show that the use of Ordinary Poisson OSEM-3D, where all corrections are applied during the iterative steps, allows to avoid this bias without compromising spatial resolution, at a price of a lower convergence rate.
引用
收藏
页码:3492 / 3496
页数:5
相关论文
共 50 条
  • [21] Full 3D-OSEM reconstruction with compressed response of the system
    Herraiz, JL
    España, S
    Vaquero, JJ
    Desco, M
    Udias, JM
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2952 - 2956
  • [22] 3D-OSEM reconstruction from truncated data in pinhole SPECT
    Zeniya, Tsutomu
    Watabe, Hiroshi
    Sohlberg, Antti
    Inomata, Toru
    Kudo, Hiroyuki
    Iida, Hidehiro
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4205 - 4207
  • [23] Design of a motion-compensation OSEM list-mode algorithm for resolution-recovery reconstruction for the HRRT
    Carson, RE
    Barker, WC
    Liow, JS
    Johnson, CA
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3281 - 3285
  • [24] An advanced fully 3D OSEM reconstruction for positron emission tomography
    贠明凯
    刘双全
    单保慈
    魏龙
    中国物理C, 2010, 34 (02) : 231 - 236
  • [25] An advanced fully 3D OSEM reconstruction for positron emission tomography
    Yun Ming-Kai
    Liu Shuang-Quan
    Shan Bao-Ci
    Wei Long
    CHINESE PHYSICS C, 2010, 34 (02) : 231 - 236
  • [26] Fully 3D Bayesian image reconstruction for the ECAT EXACT HR+
    Qi, Jinyi
    Leahy, Richard M.
    Hsu, Chinghan
    Farquhar, Thomas H.
    Cherry, Simon R.
    IEEE Transactions on Nuclear Science, 1998, 45 (3 pt 2): : 1096 - 1103
  • [27] Fully 3D Bayesian image reconstruction for the ECAT EXACT HR+
    Qi, JY
    Leahy, RM
    Hsu, CH
    Farquhar, TH
    Cherry, SR
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 953 - 957
  • [28] 3D PET reconstruction with the ECAT EXACT HR using Fourier rebinning
    Defrise, M
    Sibomana, M
    Michel, C
    Newport, D
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1316 - 1320
  • [29] Fully 3D Bayesian image reconstruction for the ECAT EXACT HR+
    Qi, JY
    Leahy, RM
    Hsu, CH
    Farquhar, TH
    Cherry, SR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1096 - 1103
  • [30] 3D-OSEM versus FORE? plus ?OSEM: Optimal Reconstruction Algorithm for FDG PET with a Short Acquisition Time
    Tsuda, Keisuke
    Suzuki, Takayuki
    Toya, Kazuhito
    Sato, Eisuke
    Fujii, Hirofumi
    WORLD JOURNAL OF NUCLEAR MEDICINE, 2023, 22 (03) : 234 - 243