3D-OSEM versus FORE? plus ?OSEM: Optimal Reconstruction Algorithm for FDG PET with a Short Acquisition Time

被引:2
|
作者
Tsuda, Keisuke [1 ,2 ]
Suzuki, Takayuki [2 ,3 ]
Toya, Kazuhito [4 ]
Sato, Eisuke [1 ]
Fujii, Hirofumi [2 ,5 ]
机构
[1] Juntendo Univ, Fac Hlth Sci, Dept Radiol Technol, Tokyo, Japan
[2] Natl Canc Ctr, Exploratory Oncol Res & Clin Trial Ctr EPOC, Div Funct Imaging, Chiba, Japan
[3] Tohto Clin, Dept Radiol, Tokyo, Japan
[4] Int Univ Hlth & Welf, Mita Hosp, Dept Radiol, Tokyo, Japan
[5] 6-5-1 Kashiwanoha, Kashiwa 2778577, Japan
关键词
positron emission tomography; short acquisition time; reconstruction; ordered subsets expectation-maximization; Fourier rebinning; OPTIMIZATION; IMAGES;
D O I
10.1055/s-0043-1774418
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveIn this study, we investigated the optimal reconstruction algorithm in fluorodeoxyglucose (FDG) positron emission tomography (PET) with a short acquisition time.Materials and MethodsIn the phantom study, six spheres filled with FDG solution (sphere size: 6.23-37 mm; radioactivity ratio of spheres to background = 8:1) and placed in a National Electrical Manufacturers Association phantom were evaluated. Image acquisition time was 15 to 180 seconds, and the obtained image data were reconstructed using each of the Fourier rebinning (FORE) + ordered subsets expectation-maximization (OSEM) and 3D-OSEM algorithms. In the clinical study, mid-abdominal images of 19 patients were evaluated using regions of interest placed on areas of low, intermediate, and high radioactivity. All obtained images were investigated visually, and quantitatively using maximum standardized uptake value (SUV) and coefficient of variation (CV).ResultsIn the phantom study, FORE + OSEM images with a short acquisition time had large CVs (poor image quality) but comparatively constant maximum SUVs. 3D-OSEM images showed comparatively constant CVs (good image quality) but significantly low maximum SUVs. The results of visual evaluation were well correlated with those of quantitative evaluation. Small spheres were obscured on 3D-OSEM images with short acquisition time, but image quality was not greatly deteriorated. The clinical and phantom studies yielded similar results.ConclusionFDG PET images with a short acquisition time reconstructed by FORE + OSEM showed poorer image quality than by 3D-OSEM. However, images obtained with a short acquisition time and reconstructed with FORE + OSEM showed clearer FDG uptake and more useful than 3D-OSEM in the light of the detection of lesions.
引用
收藏
页码:234 / 243
页数:10
相关论文
共 50 条
  • [1] 3D-OSEM vs FORE plus OSEM: The optimal reconstruction algorithm in FDG PET tests with short acquisition time
    Tsuda, Keisuke
    Fukushi, Masahiro
    Hirayama, Akira
    Suzuki, Takayuki
    Toya, Kazuhito
    Koyama, Kazuya
    Iwabuchi, Yuto
    Nemoto, Koichi
    Moriyama, Noriyuki
    Fujii, Hirofumi
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [2] Comparison of 3-D reconstruction with 3D-OSEM and with FORE plus OSEM for PET
    Liu, X
    Comtat, C
    Michel, C
    Kinahan, P
    Defrise, M
    Townsend, D
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (08) : 804 - 814
  • [3] Weighted schemes applied to 3D-OSEM reconstruction in PET
    Michel, C
    Liu, X
    Sanabria, S
    Lonneux, M
    Sibomana, M
    Bol, A
    Comtat, C
    Kinahan, PE
    Townsend, DW
    Defrise, M
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1152 - 1157
  • [4] Spatial resolution of the HRRT PET scanner using 3D-OSEM PSF reconstruction
    Olesen, Oline Vinter
    Sibomana, Merence
    Keller, Sune Hogild
    Andersen, Flemming
    Jensen, Jorgen
    Holm, Soren
    Svarer, Claus
    Hojgaard, Liselotte
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3789 - 3790
  • [5] FORE(J)+OSEM2D versus OSEM3D reconstruction for large aperture rotating LSO panel detector PET prototype
    Michel, C
    Hamill, J
    Panin, V
    Conti, M
    Jones, J
    Kehren, F
    Casey, M
    Bendriem, B
    Byars, L
    Defrise, M
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1231 - 1235
  • [6] Full 3D-OSEM reconstruction with compressed response of the system
    Herraiz, JL
    España, S
    Vaquero, JJ
    Desco, M
    Udias, JM
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2952 - 2956
  • [7] 3D-OSEM reconstruction from truncated data in pinhole SPECT
    Zeniya, Tsutomu
    Watabe, Hiroshi
    Sohlberg, Antti
    Inomata, Toru
    Kudo, Hiroyuki
    Iida, Hidehiro
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4205 - 4207
  • [8] HeinzelCluster:: accelerated reconstruction for FORE and OSEM3D
    Vollmar, S
    Michel, C
    Treffert, JT
    Newport, DF
    Casey, M
    Knöss, C
    Wienhard, K
    Liu, X
    Defrise, M
    Heiss, WD
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (15): : 2651 - 2658
  • [9] HeinzelCluster:: accelerated reconstruction for FORE and OSEM3D
    Vollmar, S
    Michel, C
    Treffert, JT
    Newport, DF
    Casey, M
    Knöss, C
    Wienhard, K
    Liu, X
    Defrise, M
    Heiss, WD
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1766 - 1770
  • [10] Noise characteristics of the FORE plus OSEM(DB) reconstruction method for the MiCES PET scanner
    Lee, K
    Kinahan, PE
    Miyaoka, RS
    Fessler, JA
    Lewellen, TK
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2642 - 2646