3D-OSEM versus FORE? plus ?OSEM: Optimal Reconstruction Algorithm for FDG PET with a Short Acquisition Time

被引:2
|
作者
Tsuda, Keisuke [1 ,2 ]
Suzuki, Takayuki [2 ,3 ]
Toya, Kazuhito [4 ]
Sato, Eisuke [1 ]
Fujii, Hirofumi [2 ,5 ]
机构
[1] Juntendo Univ, Fac Hlth Sci, Dept Radiol Technol, Tokyo, Japan
[2] Natl Canc Ctr, Exploratory Oncol Res & Clin Trial Ctr EPOC, Div Funct Imaging, Chiba, Japan
[3] Tohto Clin, Dept Radiol, Tokyo, Japan
[4] Int Univ Hlth & Welf, Mita Hosp, Dept Radiol, Tokyo, Japan
[5] 6-5-1 Kashiwanoha, Kashiwa 2778577, Japan
关键词
positron emission tomography; short acquisition time; reconstruction; ordered subsets expectation-maximization; Fourier rebinning; OPTIMIZATION; IMAGES;
D O I
10.1055/s-0043-1774418
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveIn this study, we investigated the optimal reconstruction algorithm in fluorodeoxyglucose (FDG) positron emission tomography (PET) with a short acquisition time.Materials and MethodsIn the phantom study, six spheres filled with FDG solution (sphere size: 6.23-37 mm; radioactivity ratio of spheres to background = 8:1) and placed in a National Electrical Manufacturers Association phantom were evaluated. Image acquisition time was 15 to 180 seconds, and the obtained image data were reconstructed using each of the Fourier rebinning (FORE) + ordered subsets expectation-maximization (OSEM) and 3D-OSEM algorithms. In the clinical study, mid-abdominal images of 19 patients were evaluated using regions of interest placed on areas of low, intermediate, and high radioactivity. All obtained images were investigated visually, and quantitatively using maximum standardized uptake value (SUV) and coefficient of variation (CV).ResultsIn the phantom study, FORE + OSEM images with a short acquisition time had large CVs (poor image quality) but comparatively constant maximum SUVs. 3D-OSEM images showed comparatively constant CVs (good image quality) but significantly low maximum SUVs. The results of visual evaluation were well correlated with those of quantitative evaluation. Small spheres were obscured on 3D-OSEM images with short acquisition time, but image quality was not greatly deteriorated. The clinical and phantom studies yielded similar results.ConclusionFDG PET images with a short acquisition time reconstructed by FORE + OSEM showed poorer image quality than by 3D-OSEM. However, images obtained with a short acquisition time and reconstructed with FORE + OSEM showed clearer FDG uptake and more useful than 3D-OSEM in the light of the detection of lesions.
引用
收藏
页码:234 / 243
页数:10
相关论文
共 50 条
  • [21] Lesion detection in whole body FDG PET using simultaneous emission transmission acquisition and OSEM reconstruction (SET-OSEM) versus emission-only (EO) and FBP reconstruction: An ROC study.
    Fulham, MJ
    Meikle, SR
    Hooper, PK
    Silver, KM
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 287 - 287
  • [22] Image Noise Variance in 3D OSEM Reconstruction of Clinical Time-of-Flight PET
    Watson, Charles C.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1736 - 1739
  • [23] 3D-OSEM transition matrix for high resolution PET imaging with modeling of the gamma-event detection
    Ortuño, JE
    Kontaxakis, G
    Guerra, P
    Santos, A
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3046 - 3050
  • [24] Factors affecting the performance of the 3D OSEM algorithm in the reconstruction of small animal PET images.
    Yao, R
    Seidel, J
    Johnson, CA
    Daube-Witherspoon, ME
    Green, MV
    Carson, RE
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 300P - 300P
  • [25] Numerical observer studies comparing FORE plus AWOSEM, FORE plus NECOSEM, and NEC based fully 3-D OSEM for 3-D whole-body PET imaging
    Janeiro, L.
    Comtat, C.
    Lartizien, C.
    Kinahan, P. E.
    Michel, C.
    Trebossen, R.
    Almeida, P.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 1194 - 1199
  • [26] Quantification of cerebral blood flow (CBF) by means of SPECT-CT with 3D-OSEM reconstruction algorithm: A comparison with H215O PET measurement
    Okusu, Ikuko
    Shimosegawa, Eku
    Fujino, Kouichi
    Kato, Hiroki
    Watabe, Hiroshi
    Hatazawa, Jun
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [27] Optimizing FDG-PET imaging using OSEM3D and scatter correction
    Rozeboom, E. D.
    van Dalen, J. A.
    de Bruin, W. I.
    Wagenaar, N. R. L.
    Wyndaele, N. J.
    van der Jagt, L.
    Post, N.
    Slump, C. H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S205 - S205
  • [28] A method of overlap correction for fully 3D OSEM reconstruction of PET data
    Ross, S
    Stearns, C
    Manjeshwar, R
    Iatrou, M
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3497 - 3500
  • [29] Performance of the Iterative OSEM and HYPER Algorithm for Total-body PET at SUVmax with a Low 18F-FDG Activity, a Short Acquisition Time and Small Lesions
    Zan K.
    Duan Y.
    Zhao M.
    Li H.
    Cui X.
    Chai L.
    Cheng Z.
    Current Medical Imaging, 2024, 20
  • [30] Parallel OSEM reconstruction algorithm for fully 3-D SPECT on a beowulf cluster
    Zhou Rong
    Ma Tianyu
    Jin Yongjie
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1834 - 1837