Fully 3D Bayesian image reconstruction for the ECAT EXACT HR+

被引:116
|
作者
Qi, JY [1 ]
Leahy, RM
Hsu, CH
Farquhar, TH
Cherry, SR
机构
[1] Univ So Calif, Inst Signal & Image Proc, Los Angeles, CA 90089 USA
[2] Univ Calif Los Angeles, Sch Med, Crump Inst Biol Imaging, Los Angeles, CA 90024 USA
关键词
D O I
10.1109/23.681985
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A fully 3D Bayesian method is described for high resolution reconstruction of images from the Siemens/CTI ECAT EXACT HR+ whole body positron emission tomography (PET) scanner. To maximize resolution recovery from the system we model depth dependent geometric efficiency, intrinsic detector efficiency, photon pair non-colinearity, crystal penetration and inter-crystal scatter. We also explicitly model the effects of axial rebinning and angular mashing on the detection probability or system matrix. By fully exploiting sinogram symmetries and using a factored system matrix and automated indexing schemes, we are able to achieve substantial savings in both the storage size and time required to compute forward and backward projections. Reconstruction times are further reduced using multi-threaded programming on a four processor Unix server. Bayesian reconstructions are computed using a Huber prior and a shifted-Poisson likelihood model that accounts for the effects of randoms subtraction and scatter. Reconstructions of phantom data show that the 3D Bayesian method can achieve improved FWHM resolution and contrast recovery ratios at matched background noise levels compared to both the 3D reprojection method and an OSEM method based on the shifted-Poisson model.
引用
收藏
页码:1096 / 1103
页数:8
相关论文
共 50 条
  • [1] Fully 3D Bayesian image reconstruction for the ECAT EXACT HR+
    Qi, JY
    Leahy, RM
    Hsu, CH
    Farquhar, TH
    Cherry, SR
    [J]. 1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 953 - 957
  • [2] 3D PET reconstruction with the ECAT EXACT HR using Fourier rebinning
    Defrise, M
    Sibomana, M
    Michel, C
    Newport, D
    [J]. 1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1316 - 1320
  • [3] Performance of list mode data acquisition with ECAT EXACT HR and ECAT EXACT HR+ positron emission scanners
    Watabe, H
    Matsumoto, K
    Senda, M
    Iida, H
    [J]. ANNALS OF NUCLEAR MEDICINE, 2006, 20 (03) : 189 - 194
  • [4] Performance of list mode data acquisition with ECAT EXACT HR and ECAT EXACT HR+ positron emission scanners
    Hiroshi Watabe
    Keüchi Matsumoto
    Michio Senda
    Hidehiro Iida
    [J]. Annals of Nuclear Medicine, 2006, 20 : 189 - 194
  • [5] Evaluation of the ECAT EXACT HR+ 3D PET scanner in O-15-water brain activation studies
    MorenoCantu, JJ
    Thompson, CJ
    Zatorre, RJ
    [J]. 1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1280 - 1284
  • [6] Evaluation of the ECAT EXACT HR with ACSII for clinical routine 3D measurements
    Bruckbauer, T
    Wienhard, K
    Hansen, SB
    Eriksson, L
    Blomquist, G
    Dahlbom, M
    Casey, M
    [J]. 1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1378 - 1382
  • [7] Clinical oncology imaging with the ECAT EXACT HR plus operated in 3D
    Beyer, T
    Nicoletti, R
    Bruckbauer, T
    Rocak, D
    Aigner, R
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1081 - 1081
  • [8] Evaluation of the ECAT EXACT HR+: A new positron camera with 2D/3D acquisition capabilities and nearly isotropic spatial resolution.
    Bendriem, B
    Casey, M
    Dahlbom, M
    Trebossen, R
    Blohm, K
    Nutt, R
    Syrota, A
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05): : 743 - 743
  • [9] Monte Carlo simulation for the ECAT EXACT HR+ system using GATE
    Jan, S
    Comtat, C
    Strul, D
    Santin, G
    Trébossen, R
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2545 - 2548
  • [10] Quantitative imaging of yttrium-86 PET with the ECAT EXACT HR+ in 2D mode
    Kull, T
    Ruckgaber, J
    Weller, R
    Reske, S
    Glatting, G
    [J]. CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2004, 19 (04) : 482 - 490