Enhanced 3D PET OSEM reconstruction using inter-update Metz filtering

被引:51
|
作者
Jacobson, M [1 ]
Levkovitz, R
Ben-Tal, A
Thielemans, K
Spinks, T
Belluzzo, D
Pagani, E
Bettinardi, V
Gilardi, MC
Zverovich, A
Mitra, G
机构
[1] Technion Israel Inst Technol, MINERVA Optimizat Ctr, IL-32000 Haifa, Israel
[2] Hammersmith Hosp, MRC, Cyclotron Unit, London W12 0HS, England
[3] HSR, Milan, Italy
[4] Brunel Univ, Dept Math Sci, Uxbridge UB8 3PH, Middx, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2000年 / 45卷 / 08期
关键词
D O I
10.1088/0031-9155/45/8/325
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present an enhancement of the OSEM (ordered set expectation maximization) algorithm for 3D PET reconstruction, which we call the inter-update Metz filtered OSEM (IMF-OSEM). The IMF-OSEM algorithm incorporates filtering action into the image updating process in order to improve the quality of the reconstruction. With this technique, the multiplicative correction image-ordinarily used to update image estimates in plain OSEM-is applied to a Metz-filtered version of the image estimate at certain intervals. In addition, we present a software implementation that employs several high-speed features to accelerate reconstruction. These features include, firstly, forward and back projection functions which make full use of symmetry as well as a fast incremental computation technique. Secondly, the software has the capability of running in parallel mode on several processors. The parallelization approach employed yields a significant speed-up, which is nearly independent of the amount of data. Together, these features lead to reasonable reconstruction times even when using large image arrays and non-axially compressed projection data. The performance of IMF-OSEM was tested on phantom data acquired on the GE Advance scanner. Our results demonstrate that an appropriate choice of Metz filter parameters can improve the contrast-noise balance of certain regions of interest relative to both plain and post-filtered OSEM, and to the GE commercial reprojection algorithm software.
引用
收藏
页码:2417 / 2439
页数:23
相关论文
共 50 条
  • [1] Inter-update Metz filtering as regularization for variable block-ART in PET reconstruction
    Sadki, M
    San-Martin, MT
    [J]. Computational Imaging III, 2005, 5674 : 394 - 403
  • [2] INTRA- AND INTER-ITERATION 3D OSEM PET IMAGE RECONSTRUCTION
    Jeng, Wei-Min
    Hsu, Yu-Liang
    [J]. BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2007, 19 (04): : 239 - 249
  • [3] Implementation and evaluation of an ordered subsets reconstruction algorithm for transmission PET studies using median root prior and inter-update median filtering
    V. Bettinardi
    S. Alenius
    P. Numminen
    M. Teräs
    M. Gilardi
    F. Fazio
    U. Ruotsalainen
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 222 - 231
  • [4] Implementation and evaluation of an ordered subsets reconstruction algorithm for transmission PET studies using median root prior and inter-update median filtering
    Bettinardi, V
    Alenius, S
    Numminen, P
    Teräs, M
    Gilardi, MC
    Fazio, F
    Ruotsalainen, U
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (02) : 222 - 231
  • [5] A method of overlap correction for fully 3D OSEM reconstruction of PET data
    Ross, S
    Stearns, C
    Manjeshwar, R
    Iatrou, M
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3497 - 3500
  • [6] Parallelization and Runtime Prediction of the ListMode OSEM Algorithm for 3D PET Reconstruction
    Schellmann, Maraike
    Koesters, Thomas
    Gorlatch, Sergei
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2190 - 2195
  • [7] Comparison of 3-D reconstruction with 3D-OSEM and with FORE plus OSEM for PET
    Liu, X
    Comtat, C
    Michel, C
    Kinahan, P
    Defrise, M
    Townsend, D
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (08) : 804 - 814
  • [8] PET Image Reconstruction Using LOR-OSEM with a 3D Spatially Variant System Matrix
    Wiant, David B.
    Gersh, Jacob A.
    Bennett, Marcus C.
    Bourland, J. Daniel
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3752 - 3758
  • [9] Ultrafast Preconditioned Conjugate Gradient OSEM Algorithm for Fully 3D PET Reconstruction
    Hong, I. K.
    Burbar, Z.
    Michel, C.
    Leahy, R.
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2418 - +
  • [10] An evaluation of the effect of filtering in 3-D OSEM reconstruction by using data from a high-resolution PET scanner
    Baghaei, H
    Uribe, JE
    Li, HD
    Wang, Y
    Aykac, M
    Liu, YQ
    Xing, T
    Wong, WH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2381 - 2386