An evaluation of the effect of filtering in 3-D OSEM reconstruction by using data from a high-resolution PET scanner

被引:5
|
作者
Baghaei, H [1 ]
Uribe, JE [1 ]
Li, HD [1 ]
Wang, Y [1 ]
Aykac, M [1 ]
Liu, YQ [1 ]
Xing, T [1 ]
Wong, WH [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
基金
美国国家卫生研究院;
关键词
filtering; iterative algorithms; OSEM; PET; three-dimensional (3-D) image reconstruction;
D O I
10.1109/TNS.2002.803681
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We evaluated the effect of filtering in the three-dimensional (3-D) ordered subset expectation maximization (OSEM) algorithm for reconstruction of projection data obtained with a high-resolution 3-D positron emission tomography (PET) scanner. For this study, we used the inter-update Metz filtered OSEM (IMF-OSEM) algorithm, which was developed by the PARAPET project. IMF-OSEM is an implementation of the OSEM algorithm with some additional capabilities such as inter-update filtering. The projection data were acquired using the high-resolution PET camera developed at the University of Texas M. D. Anderson Cancer Center (MDAPET). This prototype camera, which is a multiring scanner without any septa, has a transaxial resolution of 2.8 mm, which allows better evaluation of the algorithm. We scanned three phantoms: a cylindrical uniform phantom, a cylindrical phantom containing four small lesion phantoms, and the Hoffman brain phantom. The effect of inter-filtering in OSEM reconstruction was evaluated by computing the noise level of the reconstructed images of the uniform phantom, studying the contrast recovery for the hot lesions in a warm background, and visually inspecting images especially those of the Hoffman brain phantom. In addition, the effect of post-filtering on the reconstructed images was evaluated. For the high statistics data, a good compromise between contrast recovery and noise level was achieved using 20-50 iterations for the plain OSEM algorithm. By visually inspecting the images of the Hoffman brain phantom and hot lesions, we observed that the plain OSEM algorithm, especially when followed by post-filtering, and the inter-update filtering with Metz power of 1 could reasonably reproduce the phantom's structure. We also found that inter-update filtering has the potential to produce a noise level and contrast recovery comparable with that using the plain OSEM algorithm at a lower iteration number; however, it also has a greater tendency to develop noise artifacts.
引用
收藏
页码:2381 / 2386
页数:6
相关论文
共 50 条
  • [1] Evaluation of the 3D IMF-OSEM algorithm by using data from a high resolution PET scanner
    Baghaei, H
    Uribe, J
    Li, HD
    Wang, Y
    Aykac, M
    Liu, YQ
    Xing, T
    Wong, WH
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1791 - 1795
  • [2] An evaluation of exact and approximate 3-D reconstruction algorithms for a high-resolution, small-animal PET scanner
    Farquhar, TH
    Chatziioannou, A
    Cherry, SR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (06) : 1073 - 1080
  • [3] Spatial resolution of the HRRT PET scanner using 3D-OSEM PSF reconstruction
    Olesen, Oline Vinter
    Sibomana, Merence
    Keller, Sune Hogild
    Andersen, Flemming
    Jensen, Jorgen
    Holm, Soren
    Svarer, Claus
    Hojgaard, Liselotte
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3789 - 3790
  • [4] 3D-OSEM iterative image reconstruction for high-resolution PET using precalculated system matrix
    Ortuno, Juan E.
    Guerra-Gutiérrez, Pedro
    Rubio, Jose L.
    Kontaxakis, George
    Santos, Andres
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 440 - 444
  • [5] Comparison of 3-D reconstruction with 3D-OSEM and with FORE plus OSEM for PET
    Liu, X
    Comtat, C
    Michel, C
    Kinahan, P
    Defrise, M
    Townsend, D
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (08) : 804 - 814
  • [6] STUDY OF A HIGH-RESOLUTION 3D PET SCANNER
    ZHANG, SP
    BRUYNDONCKX, P
    GOLDBERG, MB
    TAVERNIER, S
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 607 - 612
  • [7] A GPU-accelerated fully 3D OSEM image reconstruction for a high-resolution small animal PET scanner using dual-ended readout detectors
    Zeng, Tianyi
    Gao, Juan
    Gao, Dongfang
    Kuang, Zhonghua
    Sang, Ziru
    Wang, Xiaohui
    Hu, Lingzhi
    Chen, Qun
    Chu, Xu
    Liang, Dong
    Liu, Xin
    Yang, Yongfeng
    Zheng, Hairong
    Hu, Zhanli
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24):
  • [8] High resolution reconstruction of PET images using the iterative OSEM algorithm
    Doll, J
    Henze, M
    Bublitz, O
    Werling, A
    Adam, LE
    Haberkorn, U
    Semmler, W
    Brix, G
    [J]. NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2004, 43 (03): : 72 - 78
  • [9] Enhanced 3D PET OSEM reconstruction using inter-update Metz filtering
    Jacobson, M
    Levkovitz, R
    Ben-Tal, A
    Thielemans, K
    Spinks, T
    Belluzzo, D
    Pagani, E
    Bettinardi, V
    Gilardi, MC
    Zverovich, A
    Mitra, G
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08): : 2417 - 2439
  • [10] 3-D reconstruction of building from single high-resolution SAR image
    Fu Xing-Yu
    You Hong-Jian
    Fu Kun
    [J]. JOURNAL OF INFRARED AND MILLIMETER WAVES, 2012, 31 (06) : 569 - 576