STUDY OF A HIGH-RESOLUTION 3D PET SCANNER

被引:0
|
作者
ZHANG, SP
BRUYNDONCKX, P
GOLDBERG, MB
TAVERNIER, S
机构
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Some results of a study of the properties of a low pressure multistep avalanche chamber with BaF2 scintillators and with TMAE as the photosensitive gas for a 3D PET scanner are presented. Absolute gas amplification was carefully measured by two independent methods, giving rise to a maximum attainable total gain of the order of 10(7). A typical electron transmission efficiency of 20-30% was obtained. The time resolution of the detector can be optimized to be approximately 6 ns FWHM.
引用
下载
收藏
页码:607 / 612
页数:6
相关论文
共 50 条
  • [1] Development of pattern generation system for high-resolution 3D scanner
    Joo M.-G.
    Park S.-H.
    Chang B.-Y.
    Ryu J.-Y.
    Journal of Institute of Control, Robotics and Systems, 2021, 27 (01) : 69 - 74
  • [2] High-resolution mobile optical 3D scanner with color mapping
    Ramm, Roland
    Braeuer-Burchardt, Christian
    Kuehmstedt, Peter
    Notni, Gunther
    OPTICS FOR ARTS, ARCHITECTURE, AND ARCHAEOLOGY VI, 2017, 10331
  • [3] Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET
    Gu, Y.
    Matteson, J. L.
    Skelton, R. T.
    Deal, A. C.
    Stephan, E. A.
    Duttweiler, F.
    Gasaway, T. M.
    Levin, C. S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (06): : 1563 - 1584
  • [5] Experience with fully 3D PET and implications for future high-resolution 3D tomographs
    Bailey, DL
    Miller, MP
    Spinks, TJ
    Bloomfield, PM
    Livieratos, L
    Young, HE
    Jones, T
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04): : 777 - 786
  • [6] 3D geometric normalization for the high resolution quad-HIDAC PET scanner
    Zhao, HX
    Reader, AJ
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1142 - 1146
  • [7] New method to calibrate and validate a high-resolution 3D scanner, based on photogrammetry
    Galantucci, Luigi Maria
    Lavecchia, Fulvio
    Percoco, Gianluca
    Raspatelli, Sergio
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2014, 38 (02): : 279 - 291
  • [8] ANALYTICAL STUDY OF PERFORMANCE IN A 3D PET SCANNER
    LECOMTE, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (03): : 623 - 634
  • [9] Efficient Methodology for 3D Statistical Reconstruction of High Resolution Coplanar PET/CT Scanner
    Ortuno, Juan E.
    Rubio, Jose L.
    Guerra, Pedro
    Kontaxakis, George
    Desco, Manuel
    Vaquero, Juan J.
    Santos, Andres
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4362 - +
  • [10] HIGH-RESOLUTION PHOTOABSORPTION STUDY OF THE 3D SPECTRUM OF CHROMIUM
    BAIG, MA
    RASHID, A
    AHMAD, I
    RAFI, M
    CONNERADE, JP
    HORMES, J
    JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 1990, 23 (20) : 3489 - 3509