An evaluation of exact and approximate 3-D reconstruction algorithms for a high-resolution, small-animal PET scanner

被引:17
|
作者
Farquhar, TH
Chatziioannou, A
Cherry, SR
机构
[1] Univ Calif Los Angeles, Sch Med, Dept Mol & Med Pharmacol, Div Nucl Med & Biophys, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Sch Med, Dept Mol & Med Pharmacol, Crump Inst Biol Imaging, Los Angeles, CA 90095 USA
关键词
image reconstruction; positron emission tomography (PET); small-animal PET scanner; three-dimensional (3-D) reconstruction;
D O I
10.1109/42.746722
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
MicroPET is a low-cost, high-resolution positron emission tomography (PET) scanner designed for imaging small animals. MicroPET operates exclusively without septa, acquiring fully three-dimensional (3-D) data sets. The performance of the projection-reprojection (3DRP), variable axial rebinning (VARB), single slice rebinning (SSRB), and Fourier rebinning (FORE) methods for reconstruction of microPET data were evaluated. The algorithms were compared with respect to resolution, noise variance, and reconstruction time. Results suggested that the 3DRP algorithm gives the best combination of resolution and noise prformance in 9 min of reconstruction time on a Sun UltraSparc I workstation. The FORE algorithm provided the most acceptable accelerated method of reconstruction, giving similar resolution performance with a 10%-20% degradation in noise variance in under 2 min. Significant degradation in the axial resolution was measured with the VARB and SSRB methods, offsetting the decrease in reconstruction time achieved with those methods. In-plane angular mashing of the 3-D data before reconstruction led to a 50% reduction in reconstruction time but also introduced unacceptable tangential blurring artifacts, This thorough evaluation of analytical 3-D reconstruction techniques allowed for optimal selection of a reconstruction method for the diverse range of microPET applications.
引用
收藏
页码:1073 / 1080
页数:8
相关论文
共 50 条
  • [1] High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner
    Qi, JY
    Leahy, RM
    Cherry, SR
    Chatziioannou, A
    Farquhar, TH
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04): : 1001 - 1013
  • [2] A Prototype High-Resolution Small-Animal PET Scanner Dedicated to Mouse Brain Imaging
    Yang, Yongfeng
    Bec, Julien
    Zhou, Jian
    Zhang, Mengxi
    Judenhofer, Martin S.
    Bai, Xiaowei
    Di, Kun
    Wu, Yibao
    Rodriguez, Mercedes
    Dokhale, Purushottam
    Shah, Kanai S.
    Farrell, Richard
    Qi, Jinyi
    Cherry, Simon R.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (07) : 1130 - 1135
  • [3] Evaluation of 3D image reconstruction methods for a dual-head small-animal PET scanner
    Kao, Chien-Min
    Dong, Yun
    Xie, Qingguo
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3046 - +
  • [4] An evaluation of the effect of filtering in 3-D OSEM reconstruction by using data from a high-resolution PET scanner
    Baghaei, H
    Uribe, JE
    Li, HD
    Wang, Y
    Aykac, M
    Liu, YQ
    Xing, T
    Wong, WH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2381 - 2386
  • [5] Spatial Resolution and Sensitivity of the Inveon Small-Animal PET Scanner
    Visser, Eric P.
    Disselhorst, Jonathan A.
    Brom, Maarten
    Laverman, Peter
    Gotthardt, Martin
    Oyen, Wim J. G.
    Boerman, Otto C.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (01) : 139 - 147
  • [6] Exact and approximate rebinning algorithms for 3-D PET data
    Defrise, M
    Kinahan, PE
    Townsend, DW
    Michel, C
    Sibomana, M
    Newport, DF
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) : 145 - 158
  • [7] Performance of a PET Insert for High-Resolution Small-Animal PET/MRI at 7 Tesla
    Stortz, Greg
    Thiessen, Jonathan D.
    Bishop, Daryl
    Khan, Muhammad Salman
    Kozlowski, Piotr
    Retiere, Fabrice
    Schellenberg, Graham
    Shams, Ehsan
    Zhang, Xuezhu
    Thompson, Christopher J.
    Goertzen, Andrew L.
    Sossi, Vesna
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (03) : 536 - 542
  • [8] PERFORMANCE EVALUATION OF THE HIGH-RESOLUTION PET SCANNER ECAT EXACT HR
    WIENHARD, K
    DAHLBOM, M
    ERIKSSON, L
    MICHEL, C
    PIETRZYK, U
    HEISS, WD
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P101 - P101
  • [9] High-resolution SPECT for small-animal imaging
    QI Yu-Jin (Shanghai Institute of Applied Physics
    [J]. Nuclear Science and Techniques, 2006, (03) : 164 - 169
  • [10] Evaluation of 3D reconstruction algorithms for a small animal PET camera
    Johnson, CA
    Seidel, J
    Carson, RE
    Gandler, WR
    Sofer, A
    Green, MV
    DaubeWitherspoon, ME
    [J]. 1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1481 - 1485