High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner

被引:522
|
作者
Qi, JY
Leahy, RM
Cherry, SR
Chatziioannou, A
Farquhar, TH
机构
[1] Univ So Calif, Inst Signal & Image Proc, Los Angeles, CA 90089 USA
[2] Univ Calif Los Angeles, Sch Med, Crump Inst Biol Imaging, Div Imaging Sci, Los Angeles, CA 90024 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1998年 / 43卷 / 04期
关键词
D O I
10.1088/0031-9155/43/4/027
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A Bayesian method is described for reconstruction of high-resolution 3D images from the microPET small-animal scanner. Resolution recovery is achieved by explicitly modelling the depth dependent geometric sensitivity for each voxel in combination with an accurate detector response model that includes factors due to photon pair non-collinearity and inter-crystal scatter and penetration. To reduce storage and computational costs we use a factored matrix in which the detector response is modelled using a sinogram blurring kernel. Maximum a posteriori (MAP) images are reconstructed using this model in combination with a Poisson likelihood function and a Gibbs prior on the image. Reconstructions obtained from point source data using the accurate system model demonstrate a potential for near-isotropic FWHM resolution of approximately 1.2 mm at the center of the held of view compared with approximately 2 mm when using an analytic 3D reprojection (3DRP) method with a ramp filter. These results also show the ability of the accurate system model to compensate for resolution loss due to crystal penetration producing nearly constant radial FWHM resolution of 1 mm out to a 4 mm radius. Studies with a point source in a uniform cylinder indicate that as the resolution of the image is reduced to control noise propagation the resolution obtained using the accurate system model is superior to that obtained using 3DRP at matched background noise levels. Additional studies using pie phantoms with hot and cold cylinders of diameter 1-2.5 mm and (18)FDG animal studies appear to confirm this observation.
引用
收藏
页码:1001 / 1013
页数:13
相关论文
共 50 条
  • [1] An evaluation of exact and approximate 3-D reconstruction algorithms for a high-resolution, small-animal PET scanner
    Farquhar, TH
    Chatziioannou, A
    Cherry, SR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (06) : 1073 - 1080
  • [2] Evaluation of 3D image reconstruction methods for a dual-head small-animal PET scanner
    Kao, Chien-Min
    Dong, Yun
    Xie, Qingguo
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3046 - +
  • [3] A GPU-accelerated fully 3D OSEM image reconstruction for a high-resolution small animal PET scanner using dual-ended readout detectors
    Zeng, Tianyi
    Gao, Juan
    Gao, Dongfang
    Kuang, Zhonghua
    Sang, Ziru
    Wang, Xiaohui
    Hu, Lingzhi
    Chen, Qun
    Chu, Xu
    Liang, Dong
    Liu, Xin
    Yang, Yongfeng
    Zheng, Hairong
    Hu, Zhanli
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24):
  • [4] Adaptation, Commissioning, and Evaluation of a 3D Treatment Planning System for High-Resolution Small-Animal Irradiation
    Jeong, Jeho
    Chen, Qing
    Febo, Robert
    Yang, Jie
    Hai Pham
    Xiong, Jian-Ping
    Zanzonico, Pat B.
    Deasy, Joseph O.
    Humm, John L.
    Mageras, Gig S.
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (03) : 460 - 471
  • [5] A Prototype High-Resolution Small-Animal PET Scanner Dedicated to Mouse Brain Imaging
    Yang, Yongfeng
    Bec, Julien
    Zhou, Jian
    Zhang, Mengxi
    Judenhofer, Martin S.
    Bai, Xiaowei
    Di, Kun
    Wu, Yibao
    Rodriguez, Mercedes
    Dokhale, Purushottam
    Shah, Kanai S.
    Farrell, Richard
    Qi, Jinyi
    Cherry, Simon R.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (07): : 1130 - 1135
  • [6] High-resolution SPECT for small-animal imaging
    QI Yu-Jin (Shanghai Institute of Applied Physics
    [J]. Nuclear Science and Techniques, 2006, (03) : 164 - 169
  • [7] Fully 3D uniform resolution transmission microPET image reconstruction
    Bai, B
    Chow, P
    Chatziioannou, A
    Leahy, RM
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1470 - 1473
  • [8] Image-guided cardiac cell delivery using high-resolution small-animal ultrasound
    Rodriguez-Porcel, M
    Gheysens, O
    Chen, IY
    Wu, JC
    Gambhir, SS
    [J]. MOLECULAR THERAPY, 2005, 12 (06) : 1142 - 1147
  • [9] Tomographic small-animal imaging using a high-resolution semiconductor camera
    Kastis, GA
    Wu, MC
    Balzer, SJ
    Wilson, DW
    Furenlid, LR
    Stevenson, G
    Barber, HB
    Barrett, HH
    Woolfenden, JM
    Kelly, P
    Appleby, M
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) : 172 - 175
  • [10] 3D model localisation using high-resolution reconstruction of monocular image sequences
    Serra, B