Evaluation of the 3D IMF-OSEM algorithm by using data from a high resolution PET scanner

被引:0
|
作者
Baghaei, H [1 ]
Uribe, J [1 ]
Li, HD [1 ]
Wang, Y [1 ]
Aykac, M [1 ]
Liu, YQ [1 ]
Xing, T [1 ]
Wong, WH [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have evaluated the 3D Ordered Subset Expectation Maximization (OSEM) algorithm for reconstruction of the projection data from a high-resolution 3D PET scanner. For this study, we used the inter-update Metz filtered OSEM (IMF-OSEM) algorithm, which has been developed by PARAPET project. The IMF-OSEM is an implementation of the OSEM algorithm with some additional capabilities such as inter-update filtering and random permutation of the subsets in each iteration. The projection data were acquired with the high-resolution PET camera developed at MD Anderson Cancer Center (MDAPET). This prototype camera, which is a multiring scanner with no septa, has a transaxial resolution of 2.8 mm that allows a better evaluation of the algorithm. We scanned three phantoms: a cylindrical uniform phantom, a cylindrical phantom with four small lesions, and the Hoffman brain phantom. The evaluation of the OSEM algorithm was performed by computing the noise level of the reconstructed images of the uniform phantom and by studying the contrast recovery for the hot lesions in warm background and also by visual inspection of images especially for the Hoffman brain phantom. In addition, the effects of post filtering and filtering during the reconstruction process have been evaluated. We observed that for the high statistics data, a good compromise between contrast recovery and noise level was achieved between 20 to 40 iterations for plain OSEM algorithm. By visually inspecting the images of Hoffman brain phantom and hot lesions, we observed that plain-OSEM algorithm, especially when followed by post-filtering, could also reasonably reproduce the phantom's structure. We also found that inter-update filtering has the potential to reach a noise level and contrast comparable to those from plain-OSEM at a smaller iteration number; however, it also has a higher tendency to develop noise artifacts.
引用
收藏
页码:1791 / 1795
页数:5
相关论文
共 50 条
  • [1] An evaluation of the effect of filtering in 3-D OSEM reconstruction by using data from a high-resolution PET scanner
    Baghaei, H
    Uribe, JE
    Li, HD
    Wang, Y
    Aykac, M
    Liu, YQ
    Xing, T
    Wong, WH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2381 - 2386
  • [2] Fast Computation of High Resolution LOR-Based 3D OSEM PET Algorithm Using the GPU Device
    Nassiri, M.
    Despres, P.
    Hissoiny, S.
    Carrier, J.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Spatial resolution of the HRRT PET scanner using 3D-OSEM PSF reconstruction
    Olesen, Oline Vinter
    Sibomana, Merence
    Keller, Sune Hogild
    Andersen, Flemming
    Jensen, Jorgen
    Holm, Soren
    Svarer, Claus
    Hojgaard, Liselotte
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3789 - 3790
  • [4] STUDY OF A HIGH-RESOLUTION 3D PET SCANNER
    ZHANG, SP
    BRUYNDONCKX, P
    GOLDBERG, MB
    TAVERNIER, S
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 607 - 612
  • [5] High resolution reconstruction of PET images using the iterative OSEM algorithm
    Doll, J
    Henze, M
    Bublitz, O
    Werling, A
    Adam, LE
    Haberkorn, U
    Semmler, W
    Brix, G
    [J]. NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2004, 43 (03): : 72 - 78
  • [6] Parallelization and Runtime Prediction of the ListMode OSEM Algorithm for 3D PET Reconstruction
    Schellmann, Maraike
    Koesters, Thomas
    Gorlatch, Sergei
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2190 - 2195
  • [7] A GPU-accelerated fully 3D OSEM image reconstruction for a high-resolution small animal PET scanner using dual-ended readout detectors
    Zeng, Tianyi
    Gao, Juan
    Gao, Dongfang
    Kuang, Zhonghua
    Sang, Ziru
    Wang, Xiaohui
    Hu, Lingzhi
    Chen, Qun
    Chu, Xu
    Liang, Dong
    Liu, Xin
    Yang, Yongfeng
    Zheng, Hairong
    Hu, Zhanli
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (24):
  • [8] 3D geometric normalization for the high resolution quad-HIDAC PET scanner
    Zhao, HX
    Reader, AJ
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1142 - 1146
  • [9] A method of overlap correction for fully 3D OSEM reconstruction of PET data
    Ross, S
    Stearns, C
    Manjeshwar, R
    Iatrou, M
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3497 - 3500
  • [10] Ultrafast Preconditioned Conjugate Gradient OSEM Algorithm for Fully 3D PET Reconstruction
    Hong, I. K.
    Burbar, Z.
    Michel, C.
    Leahy, R.
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2418 - +