Weighted schemes applied to 3D-OSEM reconstruction in PET

被引:0
|
作者
Michel, C [1 ]
Liu, X [1 ]
Sanabria, S [1 ]
Lonneux, M [1 ]
Sibomana, M [1 ]
Bol, A [1 ]
Comtat, C [1 ]
Kinahan, PE [1 ]
Townsend, DW [1 ]
Defrise, M [1 ]
机构
[1] Catholic Univ Louvain, PET Lab, B-3000 Louvain, Belgium
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to better preserve the Poisson characteristics of PET data when using 3D OSEM iterative reconstruction, we have compared images reconstructed by various data weighting schemes: unweighted, attenuation weighted, attenuation and normalization weighted OSEM 3D, FORE + unweighted and attenuation weighted OSEM 2D using 3DRP and FORE + FBP Images as reference. Due to better noise modeling, 3D weighted OSEM schemes are expected to produce better images (i.e, noise-bias trade-off) especially at low statistics, in short Frames of dynamic studies and when bed overlap is suboptimal, as in 3D wholebody studies. These reconstruction methods were implemented on the ECAT Exact HR and quantification was validated an clinical data. Their influence on physiological parameter measurements was examined on a dynamic brain receptor study with C-11-Flumazenil and a wholebody study with (18)FDG. The 3D weighted OSEM schemes provide unbiased results in volume of interests. The resulting noise reduction may lead to more accurate registration, acquisition of shorter frames and generation of parametric images.
引用
收藏
页码:1152 / 1157
页数:2
相关论文
共 50 条
  • [41] Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET
    Rapisarda, E.
    Bettinardi, V.
    Thielemans, K.
    Gilardi, M. C.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (14): : 4131 - 4151
  • [42] The effect of count statistics on the convergence value in OSEM reconstruction in PET and TOF PET
    Mettivier, G.
    Salvati, R.
    Conti, M.
    Russo, P.
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2400 - 2406
  • [43] A method for OSEM PET Reconstruction on parallel architectures using STIR
    Beisel, Tobias
    Lietsch, Stefan
    Thielemans, Kris
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3436 - +
  • [44] A modified OSEM algorithm for PET reconstruction using wavelet processing
    Lee, NY
    Choi, Y
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2005, 80 (03) : 236 - 245
  • [45] Similarity-Regulated OSEM reconstruction for pinhole-PET
    Vaissier, Pieter
    Goorden, Marlies
    Beekman, Frederik
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [46] Optimized projection ordering schemes for Compton camera reconstruction using OSEM
    Kim, Soo Mee
    Lee, Jae Sung
    Lee, Chun Sik
    Kim, Chan Hyeong
    Lee, Myung Chul
    Lee, Dong Soo
    Lee, Soo-Jin
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [47] An evaluation of the effect of filtering in 3-D OSEM reconstruction by using data from a high-resolution PET scanner
    Baghaei, H
    Uribe, JE
    Li, HD
    Wang, Y
    Aykac, M
    Liu, YQ
    Xing, T
    Wong, WH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2381 - 2386
  • [48] Comparison of 10 versus 20 mm SPECT 99mTc-MDP bone scans: use of 3D-OSEM image reconstruction with distance-dependent resolution modelling
    Livieratos, Lefteris
    Mohan, Hosahalli
    Gnanasegaran, Gopinath
    Fogelman, Ignac
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2010, 31 (12) : 1045 - 1053
  • [49] An advanced fully 3D OSEM reconstruction for positron emission tomography
    贠明凯
    刘双全
    单保慈
    魏龙
    [J]. Chinese Physics C, 2010, 34 (02) : 231 - 236
  • [50] An advanced fully 3D OSEM reconstruction for positron emission tomography
    Yun Ming-Kai
    Liu Shuang-Quan
    Shan Bao-Ci
    Wei Long
    [J]. CHINESE PHYSICS C, 2010, 34 (02) : 231 - 236