Tomosynthesis and cone-beam CT on a mobile C-arm for image-guided interventions

被引:0
|
作者
Daly, M.
Siewerdsen, J.
Bachar, G.
Moseley, D.
Chhabra, S.
Jaffray, D.
Irish, J.
机构
[1] Princess Margaret Hosp, Ontario Canc Inst, Toronto, ON M4X 1K9, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[3] Princess Margaret Hosp, Dept Radiat Phys, Toronto, ON M4X 1K9, Canada
[4] Univ Toronto, Dept Otolaryngol Head & Neck Surg, Toronto, ON, Canada
关键词
D O I
10.1118/1.2761654
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A prototype mobile C‐arm capable of real‐time fluoroscopy, tomosynthesis, and cone‐beam CT (CBCT) has been developed for intraoperative guidance of minimally invasive procedures. This work investigates the imaging performance, radiation dose, and image acquisition / reconstruction time associated with a range of 3D imaging techniques. In addition, protocols for intraoperative use are developed for implementation in clinical research trials. Method and Materials: Imaging performance was assessed in terms of spatial resolution as well as soft‐tissue and bony detail visualization in phantoms and cadavers. Image reconstruction via 3D filtered backprojection was performed across a range of tomosynthesis angle (10°–178°) and number of projections (5–200). The corresponding radiation dose was evaluated analytically and experimentally (using a Farmer chamber in cylindrical head and body phantoms) to quantify peripheral, central, and organ dose (e.g., dose to the eyes). Acquisition / reconstruction times were benchmarked in relation to operational time constraints. Results: CBCT images exhibited sub‐mm spatial resolution and soft‐tissue visibility (∼20 HU) sufficient for interventional guidance at a central dose of 10 mGy. Tomosynthesis offered a useful, high‐speed adjuvant to CBCT, providing visualization of high‐contrast features at a fairly limited arc — e.g., visualization of the clivus (skull base) achieved at angles down to ∼30° (central dose ∼1.6 mGy). Reconstruction times were ∼62 sec (full CBCT volume, 0.8 mm voxels) and ∼20 sec (tomosynthesis “slab,” 0.4 mm voxels), respectively.Conclusion:C‐arm tomosynthesis and CBCT provide a valuable addition to the image guidance arsenal. The former offers fast, low‐dose 3D images sufficient for guidance with respect to high‐contrast bony features. The latter offers sub‐mm spatial resolution and soft‐tissue visibility at the cost of time and dose. Deployment of the C‐arm prototype in clinical research trials promises increased surgical precision, with protocols for intraoperative imaging consistent with operational time and dose constraints. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2624 / 2625
页数:2
相关论文
共 50 条
  • [31] Volume-of-change cone-beam CT for image-guided surgery
    Lee, Junghoon
    Stayman, J. Webster
    Otake, Yoshito
    Schafer, Sebastian
    Zbijewski, Wojciech
    Khanna, A. Jay
    Prince, Jerry L.
    Siewerdsen, Jeffrey H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (15): : 4969 - 4989
  • [32] Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance
    Schafer, S.
    Nithiananthan, S.
    Mirota, D. J.
    Uneri, A.
    Stayman, J. W.
    Zbijewski, W.
    Schmidgunst, C.
    Kleinszig, G.
    Khanna, A. J.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2011, 38 (08) : 4563 - 4574
  • [33] High-Accuracy 3D Image-Based Registration of Endoscopic Video to C-Arm Cone-Beam CT for Image-Guided Skull Base Surgery
    Mirota, Daniel J.
    Uneri, Ali
    Schafer, Sebastian
    Nithiananthan, Sajendra
    Reh, Douglas D.
    Gallia, Gary L.
    Taylor, Russell H.
    Hager, Gregory D.
    Siewerdsen, Jeffrey H.
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [34] C-arm fluoroscopic cone-beam CT for guidance of chemical thoracic sympathectomy
    Hirose, Munetaka
    Tabata, Mari
    Sakai, Mikako
    Takeuchi, Kenji
    JOURNAL OF ANESTHESIA, 2011, 25 (01) : 142 - 143
  • [35] C-arm orbits for metal artifact avoidance (MAA) in cone-beam CT
    Wu, P.
    Sheth, N.
    Sisniega, A.
    Uneri, A.
    Han, R.
    Vijayan, R.
    Vagdargi, P.
    Kreher, B.
    Kunze, H.
    Kleinszig, G.
    Vogt, S.
    Lo, S-F
    Theodore, N.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (16):
  • [36] Geometric calibration of an extended view C-arm platform for cone-beam CT
    Cho, Y
    Kim, S
    Siewerdsen, J
    Moseley, D
    Jaffray, D
    MEDICAL PHYSICS, 2005, 32 (06) : 1937 - 1937
  • [37] Motion Compensation Using Range Imaging in C-Arm Cone-Beam CT
    Bier, Bastian
    Unberath, Mathias
    Geimer, Tobias
    Maier, Jennifer
    Gold, Garry
    Levenston, Marc
    Fahrig, Rebecca
    Maier, Andreas
    MEDICAL IMAGE UNDERSTANDING AND ANALYSIS (MIUA 2017), 2017, 723 : 561 - 570
  • [38] C-arm fluoroscopic cone-beam CT for guidance of chemical thoracic sympathectomy
    Munetaka Hirose
    Mari Tabata
    Mikako Sakai
    Kenji Takeuchi
    Journal of Anesthesia, 2011, 25 : 142 - 143
  • [39] Enlarging the longitudinal coverage of a prototype C-arm photon counting CT system for image-guided interventions
    Treb, Kevin
    Ji, Xu
    Feng, Mang
    Zhang, Ran
    Periyasamy, Sarvesh
    Laeseke, Paul F.
    Li, Ke
    MEDICAL IMAGING 2022: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2022, 12034
  • [40] 4D Respiratory Cone-Beam CT Imaging for Thoracic Interventions on Robotic C-Arm Systems
    Reynolds, T.
    Dillon, O. T.
    Hindley, N.
    Ma, Y.
    Stayman, J. W.
    Bazalova-Carter, M.
    MEDICAL PHYSICS, 2024, 51 (09) : 6643 - 6643