Enlarging the longitudinal coverage of a prototype C-arm photon counting CT system for image-guided interventions

被引:1
|
作者
Treb, Kevin [1 ]
Ji, Xu [1 ]
Feng, Mang [1 ]
Zhang, Ran [1 ]
Periyasamy, Sarvesh [2 ]
Laeseke, Paul F. [2 ]
Li, Ke [1 ,2 ]
机构
[1] Univ Wisconsin, Dept Med Phys, 1530 Med Sci Ctr, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1117/12.2612690
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Existing clinical C-arm interventional x-ray systems equipped with flat panel detectors (FPDs) can generate fluoroscopic, angiographic, and cone-beam CT (CBCT) images with sufficient volumetric coverage for interventional imaging tasks. However, FPD-CBCT does not provide sufficient low-contrast detectability, resolution, or spectral imaging capability desired for certain interventional procedures. To overcome these limitations, a C-arm photon counting detector (PCD) CT prototype was developed by installing an interchangeable strip PCD on the C-arm gantry. The narrow z width of the PCD reduces detector cost and reduces scatter when paired with a narrow beam collimation. However, it does not provide sufficient volumetric coverage compared to the standard FPD. The purpose of this work was to develop a step-and-shoot data acquisition method to enlarge the effective z-coverage of the C-arm strip PCD-CT system. A total of 10 back-and-forth short-scan C-arm gantry rotations were used with image object translation. By using an Arduino board to process the x-ray-on pulse signals in real-time, a motorized patient table prototype was synchronized with the C-arm system such that it translates the object by the PCD width during the rest time in between gantry rotations. To evaluate whether this multi-sweep step-and-shoot acquisition mode can generate high-quality and volumetric PCD-CT images, experiments were performed using an anthropomorphic head phantom, and a stent. The multi-sweep step-and-shoot C-arm protocol resulted in volumetric PCD-CT images with lower image noise and improved low-contrast visualization over the FPD-CBCT in the head phantom, as well as improved visibility of small iodinated blood vessels using maximum intensity projections. Under an ultra-high-resolution PCD mode, the fine structures of the stent were visualized more clearly by the PCD-CT than the highest-available resolution provided by the FPD-CBCT. The multi-sweep step-and-shoot acquisition can therefore extend the z-coverage of the C-arm PCD-CT prototype by a factor of 10 to enable high-quality and volumetric C-arm PCD-CT images acquired with a narrow beam-narrow detector setup for image-guided interventions.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Tomosynthesis and cone-beam CT on a mobile C-arm for image-guided interventions
    Daly, M.
    Siewerdsen, J.
    Bachar, G.
    Moseley, D.
    Chhabra, S.
    Jaffray, D.
    Irish, J.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2624 - 2625
  • [2] Imaging performance of a mobile cone-beam CT C-arm for image-guided interventions
    Daly, M.
    Siewerdsen, J.
    Moseley, D.
    Cho, Y.
    Ansell, S.
    Wilson, G.
    Jaffray, D.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2635 - 2635
  • [3] A C-arm photon counting CT prototype with volumetric coverage using multi-sweep step-and-shoot acquisitions
    Treb, Kevin
    Ji, Xu
    Feng, Mang
    Zhang, Ran
    Periyasamy, Sarvesh
    Laeseke, Paul F.
    Dingle, Aaron M.
    Brace, Christopher L.
    Li, Ke
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (21):
  • [4] A robotic C-arm cone beam CT system for image-guided proton therapy: design and performance
    Hua, Chiaho
    Yao, Weiguang
    Kidani, Takao
    Tomida, Kazuo
    Ozawa, Saori
    Nishimura, Takenori
    Fujisawa, Tatsuya
    Shinagawa, Ryousuke
    Merchant, Thomas E.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1079):
  • [5] Development of a Prototype C-Arm Photon Counting Detector CT System for Interventional Imaging: First in Vivo Animal Results
    Ji, X.
    Periyasamy, S.
    Feng, M.
    Chen, G.
    Laeseke, P.
    Li, K.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [6] Cone-beam CT for image-guided head and neck surgery: Assessment of dose and image quality using a C-arm prototype
    Daly, M.
    Siewerdsen, J.
    Moseley, D.
    Jaffray, D.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2229 - 2229
  • [7] Design and Evaluation of a Robotic C-Arm CBCT System for Image-Guided Proton Therapy
    Hua, C.
    Yao, W.
    Kidani, T.
    Farr, J.
    Tomida, K.
    Ozawa, S.
    Nishimura, T.
    Fujusawa, T.
    Shinagawa, R.
    Merchant, T.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3758 - 3758
  • [8] The MEPUC concept adapts the c-arm fluoroscope to image-guided surgery
    Suhm, N
    Müller, P
    Bopp, U
    Koller, S
    Messmer, P
    Regazzoni, P
    [J]. CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 654 - 657
  • [9] A C-Arm Calibration Method with Application to Fluoroscopic Image-guided Procedures
    Rai, Lav
    Gibbs, Jason D.
    Wibowo, Henky
    [J]. MEDICAL IMAGING 2012: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2012, 8316
  • [10] C-arm Positioning Using Virtual Fluoroscopy for Image-Guided Surgery
    De Silva, T.
    Punnoose, J.
    Uneri, A.
    Goerres, J.
    Jacobson, M.
    Ketcha, M. D.
    Manbachi, A.
    Vogt, S.
    Kleinszig, G.
    Khanna, A. J.
    Wolinksy, J. -P.
    Osgood, G.
    Siewerdsen, J. H.
    [J]. MEDICAL IMAGING 2017: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2017, 10135