Tomosynthesis and cone-beam CT on a mobile C-arm for image-guided interventions

被引:0
|
作者
Daly, M.
Siewerdsen, J.
Bachar, G.
Moseley, D.
Chhabra, S.
Jaffray, D.
Irish, J.
机构
[1] Princess Margaret Hosp, Ontario Canc Inst, Toronto, ON M4X 1K9, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[3] Princess Margaret Hosp, Dept Radiat Phys, Toronto, ON M4X 1K9, Canada
[4] Univ Toronto, Dept Otolaryngol Head & Neck Surg, Toronto, ON, Canada
关键词
D O I
10.1118/1.2761654
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A prototype mobile C‐arm capable of real‐time fluoroscopy, tomosynthesis, and cone‐beam CT (CBCT) has been developed for intraoperative guidance of minimally invasive procedures. This work investigates the imaging performance, radiation dose, and image acquisition / reconstruction time associated with a range of 3D imaging techniques. In addition, protocols for intraoperative use are developed for implementation in clinical research trials. Method and Materials: Imaging performance was assessed in terms of spatial resolution as well as soft‐tissue and bony detail visualization in phantoms and cadavers. Image reconstruction via 3D filtered backprojection was performed across a range of tomosynthesis angle (10°–178°) and number of projections (5–200). The corresponding radiation dose was evaluated analytically and experimentally (using a Farmer chamber in cylindrical head and body phantoms) to quantify peripheral, central, and organ dose (e.g., dose to the eyes). Acquisition / reconstruction times were benchmarked in relation to operational time constraints. Results: CBCT images exhibited sub‐mm spatial resolution and soft‐tissue visibility (∼20 HU) sufficient for interventional guidance at a central dose of 10 mGy. Tomosynthesis offered a useful, high‐speed adjuvant to CBCT, providing visualization of high‐contrast features at a fairly limited arc — e.g., visualization of the clivus (skull base) achieved at angles down to ∼30° (central dose ∼1.6 mGy). Reconstruction times were ∼62 sec (full CBCT volume, 0.8 mm voxels) and ∼20 sec (tomosynthesis “slab,” 0.4 mm voxels), respectively.Conclusion:C‐arm tomosynthesis and CBCT provide a valuable addition to the image guidance arsenal. The former offers fast, low‐dose 3D images sufficient for guidance with respect to high‐contrast bony features. The latter offers sub‐mm spatial resolution and soft‐tissue visibility at the cost of time and dose. Deployment of the C‐arm prototype in clinical research trials promises increased surgical precision, with protocols for intraoperative imaging consistent with operational time and dose constraints. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2624 / 2625
页数:2
相关论文
共 50 条
  • [1] Imaging performance of a mobile cone-beam CT C-arm for image-guided interventions
    Daly, M.
    Siewerdsen, J.
    Moseley, D.
    Cho, Y.
    Ansell, S.
    Wilson, G.
    Jaffray, D.
    MEDICAL PHYSICS, 2007, 34 (06) : 2635 - 2635
  • [2] Flat-panel cone-beam CT on a mobile isocentric C-arm for image-guided brachytherapy
    Jaffray, DA
    Siewerdsen, JH
    Edmundson, G
    Wong, J
    Martinez, A
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 209 - 217
  • [3] Multi-mode C-arm fluoroscopy, tomosynthesis, and cone-beam CT for image-guided interventions: From proof of principle to patient protocols
    Siewerdsen, J. H.
    Daly, M. J.
    Bachar, G.
    Moseley, D. J.
    Bootsma, G.
    Brock, K. K.
    Ansell, S.
    Wilson, G. A.
    Chhabra, S.
    Jaffray, D. A.
    Irish, J. C.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [4] Grids Revisited: The Effect of Antiscatter Grids on Image Quality and Dose in Mobile C-Arm Cone-Beam CT for Image-Guided Surgery
    Schafer, S.
    Otake, Y.
    Uneri, A.
    Mirota, D.
    Nithiananthan, S.
    Stayman, J.
    Zbijewski, W.
    Schmidgunst, C.
    Kleinszig, G.
    Siewerdsen, J.
    MEDICAL PHYSICS, 2011, 38 (06) : 3875 - +
  • [5] Design and development of C-arm based cone-beam CT for image-guided interventions: Initial results - art. no. 614210
    Chen, Guang-Hong
    Zambelli, Joseph
    Nett, Brian E.
    Supanich, Mark
    Riddell, Cyril
    Belanger, Barry
    Mistretta, Charles A.
    Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 : 14210 - 14210
  • [6] Cone-beam CT for image-guided head and neck surgery: Assessment of dose and image quality using a C-arm prototype
    Daly, M.
    Siewerdsen, J.
    Moseley, D.
    Jaffray, D.
    MEDICAL PHYSICS, 2006, 33 (06) : 2229 - 2229
  • [7] Geometric calibration of a mobile C-arm for intraoperative cone-beam CT
    Daly, M. J.
    Siewerdsen, J. H.
    Cho, Y. B.
    Jaffray, D. A.
    Irish, J. C.
    MEDICAL PHYSICS, 2008, 35 (05) : 2124 - 2136
  • [8] Dose and image quality for a cone-beam C-arm CT system
    Fahrig, Rebecca
    Dixon, Robert
    Payne, Thomas
    Morin, Richard L.
    Ganguly, Arundhuti
    Strobel, Norbert
    MEDICAL PHYSICS, 2006, 33 (12) : 4541 - 4550
  • [9] Antiscatter grids in mobile C-arm cone-beam CT: Effect on image quality and dose
    Schafer, S.
    Stayman, J. W.
    Zbijewski, W.
    Schmidgunst, C.
    Kleinszig, G.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2012, 39 (01) : 153 - 159
  • [10] C-Arm Cone-Beam CT: Principles and Applications
    Siewerdsen, J.
    Chen, G.
    MEDICAL PHYSICS, 2009, 36 (06) : 2716 - +