Tomosynthesis and cone-beam CT on a mobile C-arm for image-guided interventions

被引:0
|
作者
Daly, M.
Siewerdsen, J.
Bachar, G.
Moseley, D.
Chhabra, S.
Jaffray, D.
Irish, J.
机构
[1] Princess Margaret Hosp, Ontario Canc Inst, Toronto, ON M4X 1K9, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[3] Princess Margaret Hosp, Dept Radiat Phys, Toronto, ON M4X 1K9, Canada
[4] Univ Toronto, Dept Otolaryngol Head & Neck Surg, Toronto, ON, Canada
关键词
D O I
10.1118/1.2761654
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A prototype mobile C‐arm capable of real‐time fluoroscopy, tomosynthesis, and cone‐beam CT (CBCT) has been developed for intraoperative guidance of minimally invasive procedures. This work investigates the imaging performance, radiation dose, and image acquisition / reconstruction time associated with a range of 3D imaging techniques. In addition, protocols for intraoperative use are developed for implementation in clinical research trials. Method and Materials: Imaging performance was assessed in terms of spatial resolution as well as soft‐tissue and bony detail visualization in phantoms and cadavers. Image reconstruction via 3D filtered backprojection was performed across a range of tomosynthesis angle (10°–178°) and number of projections (5–200). The corresponding radiation dose was evaluated analytically and experimentally (using a Farmer chamber in cylindrical head and body phantoms) to quantify peripheral, central, and organ dose (e.g., dose to the eyes). Acquisition / reconstruction times were benchmarked in relation to operational time constraints. Results: CBCT images exhibited sub‐mm spatial resolution and soft‐tissue visibility (∼20 HU) sufficient for interventional guidance at a central dose of 10 mGy. Tomosynthesis offered a useful, high‐speed adjuvant to CBCT, providing visualization of high‐contrast features at a fairly limited arc — e.g., visualization of the clivus (skull base) achieved at angles down to ∼30° (central dose ∼1.6 mGy). Reconstruction times were ∼62 sec (full CBCT volume, 0.8 mm voxels) and ∼20 sec (tomosynthesis “slab,” 0.4 mm voxels), respectively.Conclusion:C‐arm tomosynthesis and CBCT provide a valuable addition to the image guidance arsenal. The former offers fast, low‐dose 3D images sufficient for guidance with respect to high‐contrast bony features. The latter offers sub‐mm spatial resolution and soft‐tissue visibility at the cost of time and dose. Deployment of the C‐arm prototype in clinical research trials promises increased surgical precision, with protocols for intraoperative imaging consistent with operational time and dose constraints. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2624 / 2625
页数:2
相关论文
共 50 条
  • [21] Role of C-Arm Cone-Beam CT in Chemoembolization for Hepatocellular Carcinoma
    Kim, Hyo-Cheol
    KOREAN JOURNAL OF RADIOLOGY, 2015, 16 (01) : 114 - 124
  • [22] Method for Metal Artifact Avoidance in C-Arm Cone-Beam CT
    Wu, P.
    Sheth, N.
    Sisniega, A.
    Uneri, A.
    Han, R.
    Vijayan, R.
    Vagdargi, P.
    Kreher, B.
    Kunze, H.
    Kleinszig, G.
    Vogt, S.
    Lo, S. -F.
    Theodore, N.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [23] Dose and detectability for a cone-beam C-arm CT system revisited
    Ganguly, Arundhuti
    Yoon, Sungwon
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2010, 37 (05) : 2264 - 2268
  • [24] Localizing spherical fiducials in C-arm based cone-beam CT
    Yaniv, Ziv
    MEDICAL PHYSICS, 2009, 36 (11) : 4957 - 4966
  • [25] Cone-beam CT: Applications in image-guided external beam radiotherapy and brachytherapy
    Jaffray, DA
    Siewerdsen, JH
    Edmundson, GE
    Wong, JW
    Martinez, A
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2044 - 2044
  • [26] Towards optimization of megavoltage cone-beam CT for image-guided radiotherapy
    Pang, G
    O'Brien, P
    Mei, X
    Tambasco, M
    Yeboah, C
    Beachey, D
    Rowlands, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S623 - S623
  • [27] Mobile C-Arm with a CMOS detector: Technical assessment of fluoroscopy and Cone-Beam CT imaging performance
    Sheth, Niral M.
    Zbijewski, Wojciech
    Jacobson, Matthew W.
    Abiola, Godwin
    Kleinszig, Gerhard
    Vogt, Sebastian
    Soellradl, Stefan
    Bialkowski, Jens
    Anderson, William S.
    Weiss, Clifford R.
    Osgood, Greg M.
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2018, 45 (12) : 5420 - 5436
  • [28] Cone-beam CT using a mobile C-arm: a registration solution for IGRT with an optical tracking system
    Sorensen, S.
    Mitschke, M.
    Solberg, T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (12): : 3389 - 3404
  • [29] Clinical implementation of cone-beam CT for image-guided radiation therapy
    Zhu, X. R.
    Zhang, L.
    Kudchadker, R.
    Wu, R.
    Balter, P.
    Mohan, R.
    Gillin, M.
    Dong, L.
    MEDICAL PHYSICS, 2006, 33 (06) : 2268 - 2268
  • [30] Patient dose in KV cone-beam CT image-guided radiotherapy
    Islam, M
    Purdie, T
    Moseley, D
    Alasti, H
    Norrlinger, B
    Sharpe, M
    Siewerdsen, J
    Jaffray, D
    MEDICAL PHYSICS, 2004, 31 (06) : 1830 - 1830