Cone-beam CT using a mobile C-arm: a registration solution for IGRT with an optical tracking system

被引:12
|
作者
Sorensen, S.
Mitschke, M.
Solberg, T.
机构
[1] Univ Calif Los Angeles, Dept Radiat Oncol, David Geffen Sch Med, Los Angeles, CA 90024 USA
[2] Siemens Oncol Care Syst, Concord, CA USA
[3] Jonsson Comprehens Canc Ctr, Los Angeles, CA 90034 USA
[4] Univ Nebraska, Med Ctr, Dept Radiat Oncol, Omaha, NE USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2007年 / 52卷 / 12期
关键词
D O I
10.1088/0031-9155/52/12/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A method for registering images acquired from a prototype flat panel mobile C-arm, capable of kilovoltage (kV) cone-beam computed tomography (CT), to a linear accelerator ( LINAC) isocenter is presented. A calibration procedure is performed which involves locating reflective markers placed on the C-arm and a phantom in two coordinate systems. A commercial optical tracking system locates the markers relative to the LINAC isocenter ( room coordinates). The cone-beam imaging capabilities of the C-arm provide the location of the markers on the calibration phantom in image coordinates. A singular value decomposition ( SVD) algorithm is used to determine the relationship between the C-arm, image coordinates and room coordinates. Once the calibration is completed, the position of the C-arm at any arbitrary location is accurately determined from the tracking system. A final transformation is calculated capable of mapping voxels in the reconstructed image set to their corresponding position in room coordinates. An evaluation to determine the accuracy of this method was performed by locating markers on a phantom. The position of the phantom markers in room coordinates was obtained directly using the optical tracking system and compared with that using the described method above. A mean absolute distance of 1.4 +/- 0.5 was observed for a completely transformed image set. This is comparable to that of systems routinely used for image-guided radiation therapy (IGRT).
引用
收藏
页码:3389 / 3404
页数:16
相关论文
共 50 条
  • [1] A mechanical solution for patient positioning using cone-beam CT acquired with a mobile C-arm
    Sorensen, S
    Mitschke, M
    Chow, P
    Wink, N
    Medin, P
    Solberg, T
    MEDICAL PHYSICS, 2004, 31 (06) : 1856 - 1856
  • [2] Cone-beam reconstruction for a C-arm CT system
    Liu, X
    Defrise, M
    Desbat, L
    Fleute, M
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1489 - 1493
  • [3] Geometric calibration of a mobile C-arm for intraoperative cone-beam CT
    Daly, M. J.
    Siewerdsen, J. H.
    Cho, Y. B.
    Jaffray, D. A.
    Irish, J. C.
    MEDICAL PHYSICS, 2008, 35 (05) : 2124 - 2136
  • [4] C-Arm Cone-Beam CT: Principles and Applications
    Siewerdsen, J.
    Chen, G.
    MEDICAL PHYSICS, 2009, 36 (06) : 2716 - +
  • [5] Dose and detectability for a cone-beam C-arm CT system revisited
    Ganguly, Arundhuti
    Yoon, Sungwon
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2010, 37 (05) : 2264 - 2268
  • [6] Dose and image quality for a cone-beam C-arm CT system
    Fahrig, Rebecca
    Dixon, Robert
    Payne, Thomas
    Morin, Richard L.
    Ganguly, Arundhuti
    Strobel, Norbert
    MEDICAL PHYSICS, 2006, 33 (12) : 4541 - 4550
  • [7] Development of a mobile C-arm platform for cone-beam CT guidance of surgical procedures
    Siewerdsen, J
    Moseley, D
    Kim, S
    Burch, S
    Bisland, S
    Bogaards, A
    Jaffray, D
    MEDICAL PHYSICS, 2004, 31 (06) : 1820 - 1820
  • [8] Tomosynthesis and cone-beam CT on a mobile C-arm for image-guided interventions
    Daly, M.
    Siewerdsen, J.
    Bachar, G.
    Moseley, D.
    Chhabra, S.
    Jaffray, D.
    Irish, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2624 - 2625
  • [9] Motion Compensation Using Range Imaging in C-Arm Cone-Beam CT
    Bier, Bastian
    Unberath, Mathias
    Geimer, Tobias
    Maier, Jennifer
    Gold, Garry
    Levenston, Marc
    Fahrig, Rebecca
    Maier, Andreas
    MEDICAL IMAGE UNDERSTANDING AND ANALYSIS (MIUA 2017), 2017, 723 : 561 - 570
  • [10] Antiscatter grids in mobile C-arm cone-beam CT: Effect on image quality and dose
    Schafer, S.
    Stayman, J. W.
    Zbijewski, W.
    Schmidgunst, C.
    Kleinszig, G.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2012, 39 (01) : 153 - 159