Cone-beam CT using a mobile C-arm: a registration solution for IGRT with an optical tracking system

被引:12
|
作者
Sorensen, S.
Mitschke, M.
Solberg, T.
机构
[1] Univ Calif Los Angeles, Dept Radiat Oncol, David Geffen Sch Med, Los Angeles, CA 90024 USA
[2] Siemens Oncol Care Syst, Concord, CA USA
[3] Jonsson Comprehens Canc Ctr, Los Angeles, CA 90034 USA
[4] Univ Nebraska, Med Ctr, Dept Radiat Oncol, Omaha, NE USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2007年 / 52卷 / 12期
关键词
D O I
10.1088/0031-9155/52/12/005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A method for registering images acquired from a prototype flat panel mobile C-arm, capable of kilovoltage (kV) cone-beam computed tomography (CT), to a linear accelerator ( LINAC) isocenter is presented. A calibration procedure is performed which involves locating reflective markers placed on the C-arm and a phantom in two coordinate systems. A commercial optical tracking system locates the markers relative to the LINAC isocenter ( room coordinates). The cone-beam imaging capabilities of the C-arm provide the location of the markers on the calibration phantom in image coordinates. A singular value decomposition ( SVD) algorithm is used to determine the relationship between the C-arm, image coordinates and room coordinates. Once the calibration is completed, the position of the C-arm at any arbitrary location is accurately determined from the tracking system. A final transformation is calculated capable of mapping voxels in the reconstructed image set to their corresponding position in room coordinates. An evaluation to determine the accuracy of this method was performed by locating markers on a phantom. The position of the phantom markers in room coordinates was obtained directly using the optical tracking system and compared with that using the described method above. A mean absolute distance of 1.4 +/- 0.5 was observed for a completely transformed image set. This is comparable to that of systems routinely used for image-guided radiation therapy (IGRT).
引用
收藏
页码:3389 / 3404
页数:16
相关论文
共 50 条
  • [41] Exact and approximate cone-beam reconstruction algorithms for C-arm based cone-beam CT using a two-concentric-arc source trajectory
    Zhuang, Tingliang
    Zambelli, Joseph
    Nett, Brian
    Leng, Shuai
    Chen, Guang-Hong
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [42] Evaluation of Effective Dose During Neuro 3-D Imaging Using a C-Arm Cone-Beam CT System
    Wang, C.
    Ferrell, A.
    Nguyen, G.
    Toncheva, G.
    Jiang, X.
    Haynes, W.
    Enterline, D.
    Smith, T.
    Yoshizumi, T.
    MEDICAL PHYSICS, 2012, 39 (06) : 3620 - 3620
  • [43] Identification of Carotid Artery Microstructure and Plaque Rupture Using C-Arm Cone-Beam CT: A Case Report
    Dong, Jia
    Bai, Xuesong
    Dmytriw, Adam A.
    Xuan, Lanlan
    Wang, Tao
    Lu, Xia
    Feng, Yao
    Jiao, Liqun
    FRONTIERS IN NEUROLOGY, 2021, 12
  • [44] Intraoperative Imaging for Patient Safety and QA: Detection of Intracranial Hemorrhage Using C-Arm Cone-Beam CT
    Schafer, Sebastian
    Wang, Adam
    Otake, Yoshito
    Stayman, J. Webster
    Zbijewski, Wojciech
    Kleinszig, Gerhard
    Xia, Xuewei
    Gallia, Gary L.
    Siewerdsen, Jeffrey H.
    MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2013, 8671
  • [45] Evaluation of Patient Effective Dose of Neurovascular Imaging Protocols for C-Arm Cone-Beam CT
    Wang, Chu
    Nguyen, Giao
    Toncheva, Greta
    Jiang, Xianxian
    Ferrell, Andrew
    Smith, Tony
    Yoshizumi, Terry
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (05) : 1072 - 1077
  • [46] C-arm cone-beam CT: General principles and technical considerations for use in interventional radiology
    Orth, Robert C.
    Wallace, Michael J.
    Kuo, Michael D.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (06) : 814 - 820
  • [47] Dynamic Range Reducer for C-Arm Cone-Beam CT Acquisitions: Initial Prototype and Evaluation
    Zhang, H.
    Bennett, N.
    Hsieh, S.
    Mueller, K.
    Fahrig, R.
    Maier, A.
    Levenston, M.
    Gold, G.
    Wang, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E393 - E393
  • [48] C-ARM CONE-BEAM CT AND TRUS GUIDED HDR-BOOST FOR PROSTATE TREATMENT
    Westendorp, R.
    Nuver, T.
    van der Molen, A.
    Kosse, J.
    Immerzeel, J.
    Hoekstra, C.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S280 - S280
  • [49] Radiation dose evaluation in tomosynthesis and C-arm cone-beam CT examinations with an anthropomorphic phantom
    Koyama, Shuji
    Aoyama, Takahiko
    Oda, Nobuhiro
    Yamauchi-Kawaura, Chiyo
    MEDICAL PHYSICS, 2010, 37 (08) : 4298 - 4306
  • [50] C-arm cone-beam CT: Applications for spinal cement augmentation demonstrated by three cases
    Knight, Jesse R.
    Heran, Manraj
    Munk, Peter L.
    Raabe, Rodney
    Liu, David M.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (07) : 1118 - 1122