Tomosynthesis and cone-beam CT on a mobile C-arm for image-guided interventions

被引:0
|
作者
Daly, M.
Siewerdsen, J.
Bachar, G.
Moseley, D.
Chhabra, S.
Jaffray, D.
Irish, J.
机构
[1] Princess Margaret Hosp, Ontario Canc Inst, Toronto, ON M4X 1K9, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[3] Princess Margaret Hosp, Dept Radiat Phys, Toronto, ON M4X 1K9, Canada
[4] Univ Toronto, Dept Otolaryngol Head & Neck Surg, Toronto, ON, Canada
关键词
D O I
10.1118/1.2761654
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A prototype mobile C‐arm capable of real‐time fluoroscopy, tomosynthesis, and cone‐beam CT (CBCT) has been developed for intraoperative guidance of minimally invasive procedures. This work investigates the imaging performance, radiation dose, and image acquisition / reconstruction time associated with a range of 3D imaging techniques. In addition, protocols for intraoperative use are developed for implementation in clinical research trials. Method and Materials: Imaging performance was assessed in terms of spatial resolution as well as soft‐tissue and bony detail visualization in phantoms and cadavers. Image reconstruction via 3D filtered backprojection was performed across a range of tomosynthesis angle (10°–178°) and number of projections (5–200). The corresponding radiation dose was evaluated analytically and experimentally (using a Farmer chamber in cylindrical head and body phantoms) to quantify peripheral, central, and organ dose (e.g., dose to the eyes). Acquisition / reconstruction times were benchmarked in relation to operational time constraints. Results: CBCT images exhibited sub‐mm spatial resolution and soft‐tissue visibility (∼20 HU) sufficient for interventional guidance at a central dose of 10 mGy. Tomosynthesis offered a useful, high‐speed adjuvant to CBCT, providing visualization of high‐contrast features at a fairly limited arc — e.g., visualization of the clivus (skull base) achieved at angles down to ∼30° (central dose ∼1.6 mGy). Reconstruction times were ∼62 sec (full CBCT volume, 0.8 mm voxels) and ∼20 sec (tomosynthesis “slab,” 0.4 mm voxels), respectively.Conclusion:C‐arm tomosynthesis and CBCT provide a valuable addition to the image guidance arsenal. The former offers fast, low‐dose 3D images sufficient for guidance with respect to high‐contrast bony features. The latter offers sub‐mm spatial resolution and soft‐tissue visibility at the cost of time and dose. Deployment of the C‐arm prototype in clinical research trials promises increased surgical precision, with protocols for intraoperative imaging consistent with operational time and dose constraints. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2624 / 2625
页数:2
相关论文
共 50 条
  • [41] Deformable image registration in cone-beam CT images for image-guided adaptive radiotherapy
    Zhang, L.
    Dong, L.
    Zhu, X.
    Garden, A.
    Ahamad, A.
    Ang, K.
    Mohan, R.
    MEDICAL PHYSICS, 2006, 33 (06) : 1995 - 1995
  • [42] 2D-3D radiograph to cone-beam computed tomography (CBCT) registration for C-arm image-guided robotic surgery
    Liu, Wen Pei
    Otake, Yoshito
    Azizian, Mahdi
    Wagner, Oliver J.
    Sorger, Jonathan M.
    Armand, Mehran
    Taylor, Russell H.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (08) : 1239 - 1252
  • [43] C-arm cone beam computed tomography needle path overlay for image-guided procedures of the spine and pelvis
    Leschka, Simon C.
    Babic, Drazenko
    El Shikh, Samer
    Wossmann, Christine
    Schumacher, Martin
    Taschner, Christian A.
    NEURORADIOLOGY, 2012, 54 (03) : 215 - 223
  • [44] C-arm cone beam computed tomography needle path overlay for image-guided procedures of the spine and pelvis
    Simon C. Leschka
    Drazenko Babic
    Samer El Shikh
    Christine Wossmann
    Martin Schumacher
    Christian A. Taschner
    Neuroradiology, 2012, 54 : 215 - 223
  • [45] Cone-beam CT based image-guided RapidArc treatment of Prostate Cancer
    Hentschel, B.
    Strauss, D.
    Berger, K.
    Dorn, U.
    Oehler, W.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 : 60 - 60
  • [46] Intraoperative cone-beam CT for image-guided tibial plateau fracture reduction
    Khoury, A.
    Siewerdsen, J. H.
    Whyne, C. M.
    Daly, M. J.
    Kreder, H. J.
    Moseley, D. J.
    Jaffray, D. A.
    COMPUTER AIDED SURGERY, 2007, 12 (04) : 195 - 207
  • [47] Fusion of Intraoperative Cone-Beam CT and Endoscopic Video for Image-Guided Procedures
    Daly, M. J.
    Chan, H.
    Prisman, E.
    Vescan, A.
    Nithiananthan, S.
    Qiu, J.
    Weersink, R.
    Irish, J. C.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [48] A personal perspective on the development and future of cone-beam CT for image-guided radiotherapy
    Jaffray, David A.
    MEDICAL PHYSICS, 2023, 50 (S1) : 54 - 57
  • [49] Kilo-voltage cone-beam CT for image-guided radiation therapy
    Sonke, JJ
    Remeijer, P
    Betgen, A
    Lebesque, J
    van Herk, M
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S70 - S70
  • [50] Image Quality Assurance Study of a Cone-Beam C-Arm CT with Automatic Exposure Control for Body Applications
    Choi, J-H
    Constantin, D.
    Nelson, G.
    Ganguly, A.
    Girard, E.
    Morin, R.
    Dixon, R.
    Fahrig, R.
    MEDICAL PHYSICS, 2013, 40 (06)