Multi-isotope SPECT imaging of the 225Ac decay chain: feasibility studies

被引:47
|
作者
Robertson, A. K. H. [1 ,2 ]
Ramogida, C. F. [1 ]
Rodriguez-Rodriguez, C. [2 ]
Blinder, Stephan [3 ]
Kunz, Peter [4 ]
Sossi, Vesna [2 ]
Schaffer, Paul [1 ,5 ]
机构
[1] TRIUMF, Div Life Sci, 4004 Wesbrook Mall, Vancouver, BC V6T 2A3, Canada
[2] Univ British Columbia, Dept Phys & Astron, 6224 Agron Rd, Vancouver, BC V6T 1Z1, Canada
[3] Univ British Columbia, Pacific Parkinsons Res Ctr, 2215 Wesbrook Mall, Vancouver, BC V6T 1Z3, Canada
[4] TRIUMF, Accelerator Div, 4004 Wesbrook Mall, Vancouver, BC V6T 2A3, Canada
[5] Univ British Columbia, Dept Radiol, 3350-950 W10th Ave, Vancouver, BC V5Z 4E3, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 11期
关键词
actinium-225; bismuth-213; francium-221; targeted alpha therapy; radioimmunotherapy; dual-isotope SPECT; TARGETED ALPHA-THERAPY; PARTICLE THERAPY; ACTINIUM-225; RADIATION; GENERATOR; PERFORMANCE; BI-213; CANCER; NOISE;
D O I
10.1088/1361-6560/aa6a99
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Effective use of the Ac-225 decay chain in targeted internal radioimmunotherapy requires the retention of both Ac-225 and progeny isotopes at the target site. Imaging-based pharmacokinetic tests of these pharmaceuticals must therefore separately yet simultaneously image multiple isotopes that may not be colocalized despite being part of the same decay chain. This work presents feasibility studies demonstrating the ability of a microSPECT/ CT scanner equipped with a high energy collimator to simultaneously image two components of the Ac-225 decay chain: Fr-221 (218 keV) and Bi-213 (440 keV). Image quality phantoms were used to assess the performance of two collimators for simultaneous Fr-221 and Bi-213 imaging in terms of contrast and noise. A hotrod resolution phantom containing clusters of thin rods with diameters ranging between 0.85 and 1.70 mm was used to assess resolution. To demonstrate ability to simultaneously image dynamic Fr-221 and Bi-213 activity distributions, a phantom containing a Bi-213 generator from Ac-225 was imaged. These tests were performed with two collimators, a high-energy ultra-high resolution (HEUHR) collimator and an ultra-high sensitivity (UHS) collimator. Values consistent with activity concentrations determined independently via gamma spectroscopy were observed in high activity regions of the images. In hotrod phantom images, the HEUHR collimator resolved all rods for both Fr-221 and 213Bi images. With the UHS collimator, no rods were resolvable in Bi-213 images and only rods. 1.3 mm were resolved in Fr-221 images. After eluting the Bi-213 generator, images accurately visualized the reestablishment of transient equilibrium of the Ac-225 decay chain. The feasibility of evaluating the pharmacokinetics of the Ac-225 decay chain in vivo has been demonstrated. This presented method requires the use of a high-performance high-energy collimator.
引用
收藏
页码:4406 / 4420
页数:15
相关论文
共 50 条
  • [31] The predicted 10.6 keV transition in 221Fr from the α-decay of 225Ac revealed
    Yakushev, EA
    Chumin, VG
    Gorozhankin, VM
    Gromov, KY
    Kovalík, A
    Filosofov, DV
    Norseev, YV
    Yurkova, LV
    JOURNAL OF PHYSICS G-NUCLEAR AND PARTICLE PHYSICS, 2002, 28 (03) : 463 - 467
  • [32] Design and development of the DE-SPECT system: a clinical SPECT system for broadband multi-isotope imaging of peripheral vascular disease
    Zannoni, E. M.
    Sankar, P.
    Jin, Y.
    Liu, C.
    Sinusas, A. J.
    Metzler, S. D.
    Meng, L. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (12):
  • [33] Detection of immunolabels with multi-isotope imaging mass spectrometry
    Thiery-Lavenant, G.
    Guillermier, C.
    Wang, M.
    Lechene, C.
    SURFACE AND INTERFACE ANALYSIS, 2014, 46 : 147 - 149
  • [34] Multi-Isotope Capabilities of a Small-Animal Multi-Pinhole SPECT System
    Lukas, Mathias
    Kluge, Anne
    Beindorff, Nicola
    Brenner, Winfried
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61 (01) : 152 - 161
  • [35] Investigation of new approaches for radiochemical separation of 225Ac isotope from proton irradiated Th target
    Younes, Ali
    Cicek, Huseyin
    Burton-Pye, Benjamin P.
    Fitzsimmons, Jonathan
    Abergel, Rebecca
    Cutler, Cathy S.
    Francesconi, Lynn C.
    JOURNAL OF LABELLED COMPOUNDS & RADIOPHARMACEUTICALS, 2017, 60 : S399 - S399
  • [36] Quantitative imaging of selenoprotein with multi-isotope imaging mass spectrometry (MIMS)
    Tang, S. S.
    Guillermier, C.
    Wang, M.
    Poczatek, J. C.
    Suzuki, N.
    Loscalzo, J.
    Lechene, C.
    SURFACE AND INTERFACE ANALYSIS, 2014, 46 : 154 - 157
  • [37] Evaluation and correction for scatter and crosstalk in multi-isotope SPECT imaging using a priori information of spectral data.
    Bouwens, LR
    Lemahieu, I
    Van Haelst, JP
    Koole, M
    Brans, B
    Dierckx, RA
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 176P - 176P
  • [38] Quantitative Multi-Isotope Imaging of Alpha-Emitter Radiopharmaceutical Therapy with the Alpha-SPECT-Mini System
    Yang, Can
    Zannoni, Elena Maria
    Cai, Ling
    Wilson, Matthew
    Bastiaannet, Remco
    Du, Yong
    Sgouros, George
    Frey, Eric
    Meng, Ling Jian
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [39] Preliminary Therapy Evaluation of 225Ac-DOTA-c (RGDyK) Demonstrates that Cerenkov Radiation Derived from 225Ac Daughter Decay Can Be Detected by Optical Imaging for In Vivo Tumor Visualization
    Pandya, Darpan N.
    Hantgan, Roy
    Budzevich, Mikalai M.
    Kock, Nancy D.
    Morse, David L.
    Batista, Izadora
    Mintz, Akiva
    Li, King C.
    Wadas, Thaddeus J.
    THERANOSTICS, 2016, 6 (05): : 698 - 709
  • [40] Compton and Proximity Imaging of 225Ac In Vivo With a CZT Gamma Camera: A Proof of Principle With Simulations
    Caravaca, Javier
    Huh, Yoonsuk
    Gullberg, Grant T.
    Seo, Youngho
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2022, 6 (08) : 904 - 915