Multi-isotope SPECT imaging of the 225Ac decay chain: feasibility studies

被引:47
|
作者
Robertson, A. K. H. [1 ,2 ]
Ramogida, C. F. [1 ]
Rodriguez-Rodriguez, C. [2 ]
Blinder, Stephan [3 ]
Kunz, Peter [4 ]
Sossi, Vesna [2 ]
Schaffer, Paul [1 ,5 ]
机构
[1] TRIUMF, Div Life Sci, 4004 Wesbrook Mall, Vancouver, BC V6T 2A3, Canada
[2] Univ British Columbia, Dept Phys & Astron, 6224 Agron Rd, Vancouver, BC V6T 1Z1, Canada
[3] Univ British Columbia, Pacific Parkinsons Res Ctr, 2215 Wesbrook Mall, Vancouver, BC V6T 1Z3, Canada
[4] TRIUMF, Accelerator Div, 4004 Wesbrook Mall, Vancouver, BC V6T 2A3, Canada
[5] Univ British Columbia, Dept Radiol, 3350-950 W10th Ave, Vancouver, BC V5Z 4E3, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 11期
关键词
actinium-225; bismuth-213; francium-221; targeted alpha therapy; radioimmunotherapy; dual-isotope SPECT; TARGETED ALPHA-THERAPY; PARTICLE THERAPY; ACTINIUM-225; RADIATION; GENERATOR; PERFORMANCE; BI-213; CANCER; NOISE;
D O I
10.1088/1361-6560/aa6a99
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Effective use of the Ac-225 decay chain in targeted internal radioimmunotherapy requires the retention of both Ac-225 and progeny isotopes at the target site. Imaging-based pharmacokinetic tests of these pharmaceuticals must therefore separately yet simultaneously image multiple isotopes that may not be colocalized despite being part of the same decay chain. This work presents feasibility studies demonstrating the ability of a microSPECT/ CT scanner equipped with a high energy collimator to simultaneously image two components of the Ac-225 decay chain: Fr-221 (218 keV) and Bi-213 (440 keV). Image quality phantoms were used to assess the performance of two collimators for simultaneous Fr-221 and Bi-213 imaging in terms of contrast and noise. A hotrod resolution phantom containing clusters of thin rods with diameters ranging between 0.85 and 1.70 mm was used to assess resolution. To demonstrate ability to simultaneously image dynamic Fr-221 and Bi-213 activity distributions, a phantom containing a Bi-213 generator from Ac-225 was imaged. These tests were performed with two collimators, a high-energy ultra-high resolution (HEUHR) collimator and an ultra-high sensitivity (UHS) collimator. Values consistent with activity concentrations determined independently via gamma spectroscopy were observed in high activity regions of the images. In hotrod phantom images, the HEUHR collimator resolved all rods for both Fr-221 and 213Bi images. With the UHS collimator, no rods were resolvable in Bi-213 images and only rods. 1.3 mm were resolved in Fr-221 images. After eluting the Bi-213 generator, images accurately visualized the reestablishment of transient equilibrium of the Ac-225 decay chain. The feasibility of evaluating the pharmacokinetics of the Ac-225 decay chain in vivo has been demonstrated. This presented method requires the use of a high-performance high-energy collimator.
引用
收藏
页码:4406 / 4420
页数:15
相关论文
共 50 条
  • [21] Multi-Isotope SPECT-based evaluation of kidney and lesion SUV and pharmacokinetics for combined Ac-225/Lu-177-PSMA-I&T therapy
    Liubchenko, G.
    Rumiantcev, M.
    Zacherl, M.
    Gildehaus, F.
    Harbach, A.
    Berg, I.
    Resch, S.
    Wenter, V.
    Bartenstein, P.
    Ziegler, S.
    Beyer, L.
    Boening, G.
    Delker, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S637 - S637
  • [22] Structure and properties of DOTA-chelated radiopharmaceuticals within the 225Ac decay pathway
    Khabibullin, Artem R.
    Karolak, Aleksandra
    Budzevich, Mikalai M.
    McLaughlin, Mark L.
    Morse, David L.
    Woods, Lilia M.
    MEDCHEMCOMM, 2018, 9 (07) : 1155 - 1163
  • [23] Feasibility of a novel photoproduction of 225Ac and 227Th with natural thorium target
    Kwangho Ju
    Yonghee Kim
    Scientific Reports, 12
  • [24] Comparison of transmission-dependent and energy-window based scatter correction methods for quantitative SPECT imaging for 225Ac
    Liubchenko, G.
    Rumiantcev, M.
    Resch, S.
    Zacherl, M.
    Gildehaus, F.
    Bartenstein, P.
    Ziegler, S.
    Boening, G.
    Delker, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S374 - S374
  • [25] Feasibility of a novel photoproduction of 225Ac and 227Th with natural thorium target
    Ju, Kwangho
    Kim, Yonghee
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [26] 225Ac imaging of NK1-targeted α-particle for glioblastoma radiotherapy
    Abou, Diane
    Guerrero-Cazares, Hugo
    Minn, Il
    Pomper, Martin
    Quinones-Hinojosa, Alfredo
    Morgenstern, Alfred
    Back, Tom
    Hobbs, Robert
    Wahl, Richard
    Sgouros, George
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [27] Estimate of the 225Ac Radioactive Isotope Distribution by Means of DOI Compton Imaging in Targeted Alpha Radiotherapy: A Monte Carlo Simulation
    Changyeon Yoon
    Seongmin Jo
    Yongho Cho
    Nakjeom Kim
    Taewoong Lee
    Journal of the Korean Physical Society, 2020, 76 : 954 - 960
  • [28] Estimate of the 225Ac Radioactive Isotope Distribution by Means of DOI Compton Imaging in Targeted Alpha Radiotherapy: A Monte Carlo Simulation
    Yoon, Changyeon
    Jo, Seongmin
    Cho, Yongho
    Kim, Nakjeom
    Lee, Taewoong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 76 (10) : 954 - 960
  • [29] Levels in 221Fr fed by the α decay of 225AC -: art. no. 064306
    Ardisson, G
    Gasparro, J
    Barci, V
    Sheline, RK
    PHYSICAL REVIEW C, 2000, 62 (06):
  • [30] 225Ac phantom characterization, in vivo mouse imaging, and quantitation on a commercial benchtop imaging system
    Hesterman, J.
    Georgiou, M.
    McCutcheon, C.
    Patel, S.
    Schneider, R.
    Alcaina, Y.
    Fysikopoulos, E.
    Lamprou, E.
    Savvidis, G.
    Loudos, G.
    Amor, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S182 - S183