Patient-Specific Quality Assurance Multi-Leaf Collimator Error Detection: Comparison of EPID and Array-Based Methods

被引:0
|
作者
Roles, S. [1 ]
Winiecki, J. [1 ]
Rapchak, A. [1 ]
Owen, G. [1 ]
Mart, C. [1 ]
McDonald, D. [1 ]
Godwin, W. [1 ]
Maynard, M. [1 ]
Peng, J. [1 ]
机构
[1] Med Univ South Carolina, Charleston, SC 29425 USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PO-GePV-T-
引用
下载
收藏
页码:E895 / E896
页数:2
相关论文
共 50 条
  • [21] Minimum requirements for commissioning and long-term quality assurance of Elekta multi-leaf collimator for volumetric modulated arc therapy
    Tatsumi D.
    Nakada R.
    Yomoda A.
    Ishii K.
    Tsutsumi S.
    Inoue M.
    Ichida T.
    Hosono M.N.
    Miki Y.
    Radiological Physics and Technology, 2013, 6 (1) : 98 - 106
  • [22] Evaluation and Validation of IBA I'MatriXX Array for Patient-Specific Quality Assurance of TomoTherapy®
    Sresty, N. V. N. Madhusudhana
    Raju, A. Krishnam
    Reddy, B. Nagarjuna
    Sahithya, V. C.
    Mohmd, Yakub
    Kumar, G. Deleep
    Kumar, T. Anil
    Rushdi, Tasneem
    Aparna, S.
    Prasad, G. Durga
    Bajwa, Harjot Kaur
    JOURNAL OF MEDICAL PHYSICS, 2019, 44 (03) : 222 - 227
  • [23] Treatment set-up verification: quality assurance technique for LINAC-based stereotactic radiosurgery/radiotherapy using micro multi-leaf collimator
    Lazaridis, EA
    Xydis, K
    Theodorou, K
    Kappas, C
    Eble, MJ
    STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 : 73 - 73
  • [24] Patient-Specific Quality Assurance in Pencil Beam Scanning by 2-Dimensional Array
    Rawiwan, Nuttida
    Chatchumnan, Nichakan
    Vimolnoch, Mananchaya
    Kingkaew, Sakda
    Oonsiri, Sornjarod
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2023, 10 (02) : 105 - 110
  • [25] Evaluation of a two-dimensional diode array for patient-specific quality assurance of HyperArc
    Popple, Richard A.
    Sullivan, Rodney J.
    Yuan, Yuan
    Wu, Xingen
    Covington, Elizabeth L.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (12): : 203 - 210
  • [26] Treatment set-up verification: quality assurance technique for linac-based stereotactic radiosurgery/radiotherapy using micro multi-leaf collimator
    Lazaridis, E
    Xydis, K
    Theodorou, K
    Kappas, C
    Eble, M
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S436 - S436
  • [27] Effect of Multileaf Collimator Leaf Position Error Determined by Picket Fence Test on Gamma Index Value in Patient-Specific Quality Assurance of Volumetric-Modulated Arc Therapy Plans
    Ceylan, Cemile
    Inal, Serpil Yondem
    Senol, Elif
    Yilmaz, Berrin
    Sahin, Sevim
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (01)
  • [28] Analysis of dose comparison techniques for patient-specific quality assurance in radiation therapy
    Yu, Liting
    Tang, Timothy L. S.
    Cassim, Naasiha
    Livingstone, Alexander
    Cassidy, Darren
    Kairn, Tanya
    Crowe, Scott B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (11): : 189 - 198
  • [29] Variation in Elekta iView electronic portal imager pixel scale factor with gantry angle, and impact on multi-leaf collimator quality assurance
    Goodall, Simon K.
    Norvill, Craig
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (07):
  • [30] Development of a deep learning-based error detection system without error dose maps in the patient-specific quality assurance of volumetric modulated arc therapy
    Kimura, Yuto
    Kadoya, Noriyuki
    Oku, Yohei
    Jingu, Keiichi
    JOURNAL OF RADIATION RESEARCH, 2023, 64 (04) : 728 - 737