Effect of Multileaf Collimator Leaf Position Error Determined by Picket Fence Test on Gamma Index Value in Patient-Specific Quality Assurance of Volumetric-Modulated Arc Therapy Plans

被引:2
|
作者
Ceylan, Cemile [1 ,2 ]
Inal, Serpil Yondem [3 ]
Senol, Elif [3 ]
Yilmaz, Berrin [1 ]
Sahin, Sevim [4 ]
机构
[1] Istanbul Oncol Hosp, Radiat Oncol Dept, Istanbul, Turkey
[2] Yeditepe Univ, Hlth Sci Inst, Istanbul, Turkey
[3] Mem Bahcelievler Hosp, Radiat Oncol Dept, Istanbul, Turkey
[4] Fenerbahce Univ, Med Imaging Dept, Istanbul, Turkey
关键词
mlc error; patient-specific quality assurance; gamma-index evaluation; DYNAMIC IMRT; SLIDING WINDOW; MLC; ACCURACY; SENSITIVITY; PERFORMANCE; DELIVERY; CONSEQUENCES;
D O I
10.7759/cureus.12684
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim The correlation between the MLC QA (IBA Dosimetry, Germany) results of the picket fence test created with intentional errors and the patient's quality assurance (QA) evaluation was investigated to assess the impact of multileaf collimator (MLC) positioning error on patient QA. Materials and methods The picket fence, including error-free and intentional MLC errors, defined in Bank In, Bank Out, and Bank Both were analyzed using MLC QA. The QA of 15 plans consisting of stereotactic radiosurgery (SRS), stereotactic body radiotherapy (SBRT), and conventionally fractionated volumetric-modulated arc therapy (VMAT) acquired with electronic portal imaging devices (EPID) was evaluated in the presence of error-free and MLC errors. The QA of plans were analyzed with 2%/2 mm and 3%/3 mm criteria. Results The passing rates of the picket fence test were 97%, 92%, 91%, and 87% for error-free and intentional errors. The criterion of 3%/3 mm wasn't able to detect an MLC error for either SRS/SBRT or conventionally fractionated VMAT. The criterion of 2%/2mm was more sensitive to detect MLC error for the conventionally fractionated VMAT than SRS/SBRT. While only two of SBRT plans had <90%, four of conventionally fractionated VMAT plans had a <90% passing rate. Conclusion We found that the systematic MLC positioning errors defined with picket fence have a smaller but measurable impact on SRS/SBRT than the VMAT plan for a conventionally fractionated and relatively complex plan such as head and neck and endometrium cases.
引用
下载
收藏
页数:13
相关论文
共 48 条
  • [1] A retrospective analysis for patient-specific quality assurance of volumetric-modulated arc therapy plans
    Li, Guangjun
    Wu, Kui
    Peng, Guang
    Zhang, Yingjie
    Bai, Sen
    MEDICAL DOSIMETRY, 2014, 39 (04) : 309 - 313
  • [2] The Effect of Multileaf Collimator Leaf Width on the Quality of Volumetric-Modulated Arc Therapy Stereotactic Radiosurgery Treatment Plans
    Laoui, S.
    Kuo, J. V.
    Al-Ghazi, M.
    Roa, D. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E682 - E683
  • [3] The sensitivity of gamma index analysis to detect multileaf collimator (MLC) positioning errors using Varian TrueBeam EPID and ArcCHECK for patient-specific prostate volumetric-modulated arc therapy (VMAT) quality assurance
    Maraghechi, Borna
    Davis, Jack
    Mitchell, Nicholas
    Shah, Meeral
    Fleck, Andre
    Darko, Johnson
    Osei, Ernest
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (01) : 66 - 77
  • [4] Predicting gamma evaluation results of patient-specific head and neck volumetric-modulated arc therapy quality assurance based on multileaf collimator patterns and fluence map features: A feasibility study
    Thongsawad, Sangutid
    Srisatit, Somyot
    Fuangrod, Todsaporn
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (07):
  • [5] VOLUMETRIC-MODULATED ARC THERAPY: EFFECTIVE AND EFFICIENT END-TO-END PATIENT-SPECIFIC QUALITY ASSURANCE
    O'Daniel, Jennifer
    Das, Shiva
    Wu, Q. Jackie
    Yin, Fang-Fang
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05): : 1567 - 1574
  • [6] A Systematic Approach to Patient-Specific Quality Assurance for Volumetric Modulated Arc Therapy
    SONG Yu-lin
    Ceferino Obcemea
    Boris Mueller
    Borys Mychalczak
    Chinese Journal of Biomedical Engineering, 2015, 24 (02) : 58 - 65
  • [7] Prospective Clinical Validation of Virtual Patient-Specific Quality Assurance of Volumetric Modulated Arc Therapy Radiation Therapy Plans
    Wall, Phillip D. H.
    Hirata, Emily
    Morin, Olivier
    Valdes, Gilmer
    Witztum, Alon
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 113 (05): : 1091 - 1102
  • [8] A TPS integrated machine learning tool for predicting patient-specific quality assurance outcomes in volumetric-modulated arc therapy
    Noblet, Caroline
    Maunet, Mathis
    Duthy, Marie
    Coste, Frederic
    Moreau, Matthieu
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 118
  • [9] Machine learning and lean six sigma for targeted patient-specific quality assurance of volumetric modulated arc therapy plans
    Lambri, Nicola
    Dei, Damiano
    Goretti, Giulia
    Crespi, Leonardo
    Brioso, Ricardo Coimbra
    Pelizzoli, Marco
    Parabicoli, Sara
    Bresolin, Andrea
    Gallo, Pasqualina
    La Fauci, Francesco
    Lobefalo, Francesca
    Paganini, Lucia
    Reggiori, Giacomo
    Loiacono, Daniele
    Franzese, Ciro
    Tomatis, Stefano
    Scorsetti, Marta
    Mancosu, Pietro
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 31
  • [10] Error detection model developed using a multi-task convolutional neural network in patient-specific quality assurance for volumetric-modulated arc therapy
    Kimura, Yuto
    Kadoya, Noriyuki
    Oku, Yohei
    Kajikawa, Tomohiro
    Tomori, Seiji
    Jingu, Keiichi
    MEDICAL PHYSICS, 2021, 48 (09) : 4769 - 4783