Patient-Specific Quality Assurance Multi-Leaf Collimator Error Detection: Comparison of EPID and Array-Based Methods

被引:0
|
作者
Roles, S. [1 ]
Winiecki, J. [1 ]
Rapchak, A. [1 ]
Owen, G. [1 ]
Mart, C. [1 ]
McDonald, D. [1 ]
Godwin, W. [1 ]
Maynard, M. [1 ]
Peng, J. [1 ]
机构
[1] Med Univ South Carolina, Charleston, SC 29425 USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PO-GePV-T-
引用
收藏
页码:E895 / E896
页数:2
相关论文
共 50 条
  • [31] Dosimetric Comparison of Robotic and Linear Accelerator Multi-Leaf Collimator-Based Stereotactic Radiosurgery for Arteriovenous Malformation
    Kaliyaperumal, Venkatesan
    Abraham, Susan
    Veni, Maragatha
    Banerjee, Susovan
    Tamilselvan, S.
    Gupta, Deepak
    Dayanithi, K.
    Manigandan, D.
    Mishra, Saumyaranjan
    Bisht, Shyam Singh
    Kataria, Tejinder
    JOURNAL OF MEDICAL PHYSICS, 2021, 46 (01) : 16 - 25
  • [32] Comparing log file to measurement-based patient-specific quality assurance
    Li Ting Chan
    Yun Inn Tan
    Poh Wee Tan
    Yuh Fun Leong
    Jong Shin Khor
    Mun Woan Teh
    Joan Faith Loria Cruz
    Sháun Peter Baggarley
    Kiat Huat Ooi
    Yiat Horng Leong
    Physical and Engineering Sciences in Medicine, 2023, 46 : 303 - 311
  • [33] An error detection method for real-time EPID-based treatment delivery quality assurance
    Alves, Victor Gabriel Leandro
    Ahmed, Mahmoud
    Aliotta, Eric
    Choi, Wookjin
    Siebers, Jeffrey Vincent
    MEDICAL PHYSICS, 2021, 48 (02) : 569 - 578
  • [34] A Swiss cheese error detection method for real-time EPID-based quality assurance and error prevention
    Passarge, Michelle
    Fix, Michael K.
    Manser, Peter
    Stampanoni, Marco F. M.
    Siebers, Jeffrey V.
    MEDICAL PHYSICS, 2017, 44 (04) : 1212 - 1223
  • [35] Dosimetric Comparison of Four Commercial Patient-Specific Quality Assurance Devices for Helical Tomotherapy
    Kyung Hwan Chang
    Dong Wook Kim
    Jung Hoan Choi
    Han-Back Shin
    Chae-Seon Hong
    Dong Min Jung
    Joo Ho Kim
    Jihun Kim
    Mincheol Han
    Ho Lee
    Kwangwoo Park
    Jin Sung Kim
    Jaeho Cho
    Yong Bae Kim
    Joo Ah Lee
    Journal of the Korean Physical Society, 2020, 76 : 257 - 263
  • [36] Dosimetric Comparison of Four Commercial Patient-Specific Quality Assurance Devices for Helical Tomotherapy
    Chang, Kyung Hwan
    Kim, Dong Wook
    Choi, Jung Hoan
    Shin, Han-Back
    Hong, Chae-Seon
    Jung, Dong Min
    Kim, Joo Ho
    Kim, Jihun
    Han, Mincheol
    Lee, Ho
    Park, Kwangwoo
    Kim, Jin Sung
    Cho, Jaeho
    Kim, Yong Bae
    Lee, Joo Ah
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 76 (03) : 257 - 263
  • [37] Patient-specific deformable image registration quality assurance based on feature points
    Park, P. C.
    Koay, E.
    Yang, J.
    Suh, Y.
    Das, P.
    Crane, C.
    Beddar, S.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S900 - S901
  • [38] Comparing log file to measurement-based patient-specific quality assurance
    Ting, Chan Li
    Inn, Tan Yun
    Wee, Tan Poh
    Leong, Leong Yuh
    Shin, Khor Jong
    Woan, Teh Mun
    Cruz, Joan Faith Loria
    Baggarley, Shaun Peter
    Huat, Ooi Kiat
    Leong, Leong Yiat
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (01) : 303 - 311
  • [39] Evaluation of DVH Based Patient-Specific Quality-Assurance Using COMPASS
    Sharma, S.
    Subramani, V.
    Chander, S.
    Bhaskar, S.
    Pathy, S.
    Kumar, P.
    Gopishankar, N.
    Thulkar, S.
    Singh, M.
    Binjola, A.
    MEDICAL PHYSICS, 2019, 46 (06) : E601 - E602
  • [40] Error detection model developed using a multi-task convolutional neural network in patient-specific quality assurance for volumetric-modulated arc therapy
    Kimura, Yuto
    Kadoya, Noriyuki
    Oku, Yohei
    Kajikawa, Tomohiro
    Tomori, Seiji
    Jingu, Keiichi
    MEDICAL PHYSICS, 2021, 48 (09) : 4769 - 4783