Comparison of Internal Anterior Chamber Diameter Imaging Modalities: 35-MHz Ultrasound Biomicroscopy, Visante Optical Coherence Tomography, and Pentacam

被引:15
|
作者
Kim, Sang-Kyoon [1 ]
Kim, Hyo-Myung [1 ]
Song, Jong-Suk [1 ]
机构
[1] Korea Univ, Coll Med, Guro Hosp, Dept Ophthalmol, Seoul 152703, South Korea
关键词
PHAKIC INTRAOCULAR LENSES; ROTATING SCHEIMPFLUG CAMERA; HIGH-FREQUENCY ULTRASOUND; CORNEAL THICKNESS; SEGMENT; MYOPIA; DIOPTERS; DEPTH; EYES;
D O I
10.3928/1081597X-20100121-07
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the internal diameter of the anterior chamber among three different imaging modalities: 35-MHz ultrasound biomicroscopy (UBM), Visante optical coherence tomography (OCT), and Pentacam, and to compare the internal diameters with white-to-white (WTW) distance measured by Orbscan. METHODS: The internal horizontal anterior chamber diameter was measured in 20 normal eyes using 35-MHz UBM (Optikon), Visante OCT (Carl Zeiss Meditec), and Pentacam (Oculus Inc). The mean horizontal anterior chamber diameters were compared, and the correlations between each pair of two different methods were evaluated. Horizontal WTW distance was measured by Orbscan Ilz (Bausch & Lomb-Orbtek Inc) and then correlated with the measurements of internal anterior chamber diameter. RESULTS: The mean horizontal anterior chamber diameter was 10.99 +/- 0.47 mm with UBM, 11.70 +/- 0.47 mm with OCT, and 11.86 +/- 0.45 mm with Pentacam. Ultrasound biomicroscopy measurements were significantly different than those of OCT and Pentacam (P<.001 for both). However, no significant difference was found between OCT and Pentacam (P=.19). Regarding the correlations between each pair of two different methods, UBM and OCT showed significant correlation (r=0.848, P<.001), but there was no significant correlation between OCT and Pentacam (r=0.403, P=.078), even though the mean values were similar. In the Bland-Altman plots, the range of agreement was 0.51 mm between OCT and UBM, and 0.99 mm between Pentacam and OCT. CONCLUSIONS: Although the internal anterior chamber diameters measured by 35-MHz UBM were significantly smaller than those measured by Visante OCT and Pentacam, the measurements of UBM and Visante OCT showed significant correlation and good agreement with each other. Pentacam showed poor correlation with other measurements. [J Refract Surg. 2010;26:120-126.] doi:10.3928/1081597X-20100121-07
引用
收藏
页码:120 / 126
页数:7
相关论文
共 50 条
  • [1] Anterior chamber volume measurements with Visante optical coherence tomography and Pentacam: repeatability and level of agreement
    Labiris, Georgios
    Gkika, Maria
    Katsanos, Andreas
    Fanariotis, Michael
    Alvanos, Efstratios
    Kozobolis, Vassilios
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 37 (08): : 772 - 774
  • [2] Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles
    Radhakrishnan, S
    Goldsmith, J
    Huang, D
    Westphal, V
    Dueker, DK
    Rollins, AM
    Izatt, JA
    Smith, SD
    ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (08) : 1053 - 1059
  • [3] Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
    Yu, Zi-Yan
    Huang, Ting
    Lu, Lu
    Qu, Bo
    WORLD JOURNAL OF CLINICAL CASES, 2020, 8 (15) : 3249 - U143
  • [4] Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy
    Zi-Yan Yu
    Ting Huang
    Lu Lu
    Bo Qu
    World Journal of Clinical Cases, 2020, (15) : 3249 - 3258
  • [5] Comparison of Visante and slit-lamp anterior segment optical coherence tomography in imaging the anterior chamber angle
    Sakata, L. M.
    Wong, T. T. L.
    Wong, H-T
    Kumar, R. S.
    Htoon, H. M.
    Aung, H. T.
    He, M.
    Aung, T.
    EYE, 2010, 24 (04) : 578 - 587
  • [6] Comparison of Visante and slit-lamp anterior segment optical coherence tomography in imaging the anterior chamber angle
    L M Sakata
    T T L Wong
    H-T Wong
    R S Kumar
    H M Htoon
    H T Aung
    M He
    T Aung
    Eye, 2010, 24 : 578 - 587
  • [7] Assessment of Anterior Chamber Depth Using Visante Optical Coherence Tomography, Slitlamp Optical Coherence Tomography, IOL Master, Pentacam and Orbscan IIz
    Dinc, Umut Asli
    Gorgun, Ebru
    Oncel, Banu
    Yenerel, Melda Nursal
    Alimgil, Levent
    OPHTHALMOLOGICA, 2010, 224 (06) : 341 - 346
  • [8] Comparison of Different Modes in Optical Coherence Tomography and Ultrasound Biomicroscopy in Anterior Chamber Angle Assessment
    Wang, Dandan
    Pekmezci, Melike
    Basham, Ryan P.
    He, Mingguang
    Seider, Michael I.
    Lin, Shan C.
    JOURNAL OF GLAUCOMA, 2009, 18 (06) : 472 - 478
  • [9] Anterior segment imaging: ultrasound biomicroscopy and anterior segment optical coherence tomography
    Nolan, Winifred
    CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (02) : 115 - 121
  • [10] Imaging of Anterior Segment Tumours: A Comparison of Ultrasound Biomicroscopy Versus Anterior Segment Optical Coherence Tomography
    Kottaridou, Eleni
    Hatoum, Adam
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)