Noise and signal properties in PSF-based fully 3D PET image reconstruction: an experimental evaluation

被引:148
|
作者
Tong, S. [1 ]
Alessio, A. M. [1 ]
Kinahan, P. E. [1 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 05期
关键词
ITERATIVE RECONSTRUCTION; FDG-PET; ALGORITHMS; RESOLUTION; SCANNER; MODEL;
D O I
10.1088/0031-9155/55/5/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The addition of accurate system modeling in PET image reconstruction results in images with distinct noise texture and characteristics. In particular, the incorporation of point spread functions (PSF) into the system model has been shown to visually reduce image noise, but the noise properties have not been thoroughly studied. This work offers a systematic evaluation of noise and signal properties in different combinations of reconstruction methods and parameters. We evaluate two fully 3D PET reconstruction algorithms: (1) OSEM with exact scanner line of response modeled (OSEM+LOR), (2) OSEM with line of response and a measured point spread function incorporated (OSEM+LOR+PSF), in combination with the effects of four post-reconstruction filtering parameters and 1-10 iterations, representing a range of clinically acceptable settings. We used a modified NEMA image quality (IQ) phantom, which was filled with Ge-68 and consisted of six hot spheres of different sizes with a target/background ratio of 4:1. The phantom was scanned 50 times in 3D mode on a clinical system to provide independent noise realizations. Data were reconstructed with OSEM+LOR and OSEM+LOR+PSF using different reconstruction parameters, and our implementations of the algorithms match the vendor's product algorithms. With access to multiple realizations, background noise characteristics were quantified with four metrics. Image roughness and the standard deviation image measured the pixel-to-pixel variation; background variability and ensemble noise quantified the region-to-region variation. Image roughness is the image noise perceived when viewing an individual image. At matched iterations, the addition of PSF leads to images with less noise defined as image roughness (reduced by 35% for unfiltered data) and as the standard deviation image, while it has no effect on background variability or ensemble noise. In terms of signal to noise performance, PSF-based reconstruction has a 7% improvement in contrast recovery at matched ensemble noise levels and 20% improvement of quantitation SNR in unfiltered data. In addition, the relations between different metrics are studied. A linear correlation is observed between background variability and ensemble noise for all different combinations of reconstruction methods and parameters, suggesting that background variability is a reasonable surrogate for ensemble noise when multiple realizations of scans are not available.
引用
收藏
页码:1453 / 1473
页数:21
相关论文
共 50 条
  • [41] Fully 3D implementation of the end-to-end deep image prior-based PET image reconstruction using block iterative algorithm
    Hashimoto, Fumio
    Onishi, Yuya
    Ote, Kibo
    Tashima, Hideaki
    Yamaya, Taiga
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (15):
  • [42] Point Cloud Noise and Outlier Removal for Image-Based 3D Reconstruction
    Wolff, Katja
    Kim, Changil
    Zimmer, Henning
    Schroers, Christopher
    Botsch, Mario
    Sorkine-Hornung, Olga
    Sorkine-Hornung, Alexander
    [J]. PROCEEDINGS OF 2016 FOURTH INTERNATIONAL CONFERENCE ON 3D VISION (3DV), 2016, : 118 - 127
  • [43] Performance of a fast maximum likelihood algorithm for fully 3D pet reconstruction
    Matej, S
    Browne, JA
    [J]. THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 1996, 4 : 297 - 315
  • [44] A method of overlap correction for fully 3D OSEM reconstruction of PET data
    Ross, S
    Stearns, C
    Manjeshwar, R
    Iatrou, M
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3497 - 3500
  • [45] Ultrafast EM-OSLE for cluster reconstruction in fully 3D PET
    Hong, I. K.
    Cho, Z. H.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3461 - +
  • [46] Maximum likelihood reconstruction in fully 3D PET via the SAGE algorithm
    Ollinger, JM
    Goggin, AS
    [J]. 1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1594 - 1598
  • [47] Bootstrap methods for estimating PET image noise: experimental validation and an application to evaluation of image reconstruction algorithms
    Masanobu Ibaraki
    Keisuke Matsubara
    Kazuhiro Nakamura
    Hiroshi Yamaguchi
    Toshibumi Kinoshita
    [J]. Annals of Nuclear Medicine, 2014, 28 : 172 - 182
  • [48] Bootstrap methods for estimating PET image noise: experimental validation and an application to evaluation of image reconstruction algorithms
    Ibaraki, Masanobu
    Matsubara, Keisuke
    Nakamura, Kazuhiro
    Yamaguchi, Hiroshi
    Kinoshita, Toshibumi
    [J]. ANNALS OF NUCLEAR MEDICINE, 2014, 28 (02) : 172 - 182
  • [49] EVALUATION OF A 3D RECONSTRUCTION ALGORITHM FOR MULTISLICE PET SCANNERS
    CHERRY, SR
    DAHLBOM, M
    HOFFMAN, EJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (03): : 779 - 790
  • [50] A Performance Evaluation of Local Features for Image-Based 3D Reconstruction
    Fan, Bin
    Kong, Qingqun
    Wang, Xinchao
    Wang, Zhiheng
    Xiang, Shiming
    Pan, Chunhong
    Fua, Pascal
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2019, 28 (10) : 4774 - 4789