Noise and signal properties in PSF-based fully 3D PET image reconstruction: an experimental evaluation

被引:148
|
作者
Tong, S. [1 ]
Alessio, A. M. [1 ]
Kinahan, P. E. [1 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 05期
关键词
ITERATIVE RECONSTRUCTION; FDG-PET; ALGORITHMS; RESOLUTION; SCANNER; MODEL;
D O I
10.1088/0031-9155/55/5/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The addition of accurate system modeling in PET image reconstruction results in images with distinct noise texture and characteristics. In particular, the incorporation of point spread functions (PSF) into the system model has been shown to visually reduce image noise, but the noise properties have not been thoroughly studied. This work offers a systematic evaluation of noise and signal properties in different combinations of reconstruction methods and parameters. We evaluate two fully 3D PET reconstruction algorithms: (1) OSEM with exact scanner line of response modeled (OSEM+LOR), (2) OSEM with line of response and a measured point spread function incorporated (OSEM+LOR+PSF), in combination with the effects of four post-reconstruction filtering parameters and 1-10 iterations, representing a range of clinically acceptable settings. We used a modified NEMA image quality (IQ) phantom, which was filled with Ge-68 and consisted of six hot spheres of different sizes with a target/background ratio of 4:1. The phantom was scanned 50 times in 3D mode on a clinical system to provide independent noise realizations. Data were reconstructed with OSEM+LOR and OSEM+LOR+PSF using different reconstruction parameters, and our implementations of the algorithms match the vendor's product algorithms. With access to multiple realizations, background noise characteristics were quantified with four metrics. Image roughness and the standard deviation image measured the pixel-to-pixel variation; background variability and ensemble noise quantified the region-to-region variation. Image roughness is the image noise perceived when viewing an individual image. At matched iterations, the addition of PSF leads to images with less noise defined as image roughness (reduced by 35% for unfiltered data) and as the standard deviation image, while it has no effect on background variability or ensemble noise. In terms of signal to noise performance, PSF-based reconstruction has a 7% improvement in contrast recovery at matched ensemble noise levels and 20% improvement of quantitation SNR in unfiltered data. In addition, the relations between different metrics are studied. A linear correlation is observed between background variability and ensemble noise for all different combinations of reconstruction methods and parameters, suggesting that background variability is a reasonable surrogate for ensemble noise when multiple realizations of scans are not available.
引用
收藏
页码:1453 / 1473
页数:21
相关论文
共 50 条
  • [21] Performance evaluation of the section of 3D reconstruction based on different PET/CT image fusion sequence
    Lo, Rong-Chin
    Huang, Wen-Lin
    Hsiao, Yu-Lin
    [J]. TECHNOLOGY AND HEALTH CARE, 2016, 24 : S357 - S367
  • [22] PET image resolution recovery using PSF-based ML-EM deconvolution with blob-based list-mode TOF reconstruction
    Zhang, Bin
    Olivier, Patrick
    Lorman, Benjamin
    Tung, Chi-hua
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [23] EVALUATION OF TASK-ORIENTED PERFORMANCE OF SEVERAL FULLY 3D PET RECONSTRUCTION ALGORITHMS
    MATEJ, S
    HERMAN, GT
    NARAYAN, TK
    FURUIE, SS
    LEWITT, RM
    KINAHAN, PE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03): : 355 - 367
  • [24] Image Noise Variance in 3D OSEM Reconstruction of Clinical Time-of-Flight PET
    Watson, Charles C.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1736 - 1739
  • [25] Model-based normalization for iterative 3D PET image reconstruction
    Bai, B
    Li, Q
    Holdsworth, CH
    Asma, E
    Tai, YC
    Chatziioannou, A
    Leahy, RM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (15): : 2773 - 2784
  • [26] Direct 3D PET Image Reconstruction into MR Image Space
    Gravel, Paul
    Verhaeghe, Jeroen
    Reader, Andrew J.
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3955 - 3962
  • [27] Fully 3D PET image reconstruction using a Fourier preconditioned conjugate-gradient algorithm
    Fessler, JA
    Ficaro, EP
    [J]. 1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1599 - 1602
  • [28] LEARNING-BASED FULLY 3D FACE RECONSTRUCTION FROM A SINGLE IMAGE
    Hu, Xiaoping
    Wang, Ying
    Zhu, Feiyun
    Pan, Chunhong
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING PROCEEDINGS, 2016, : 1651 - 1655
  • [29] Fast implementations of reconstruction-based scatter compensation in fully 3D SPECT image reconstruction
    Kadrmas, DJ
    Frey, EC
    Karimi, SS
    Tsui, BMW
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (04): : 857 - 873
  • [30] Comparision of Two Projectors with Image-Based Resolution Models in a Fully 3D List-Mode PET Reconstruction
    Ye, Hongwei
    Niu, Xiaofeng
    Ji, Changguo
    Xia, Ting
    Asma, Evren
    Winkler, Mark
    Wang, Wenli
    Gagnon, Daniel
    [J]. 2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,