Maximum likelihood reconstruction in fully 3D PET via the SAGE algorithm

被引:0
|
作者
Ollinger, JM
Goggin, AS
机构
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The SAGE and ordered subsets algorithms have been proposed as fast methods to compute penalized maximum likelihood estimates in PET. We have implemented both for use in fully 3D PET and completed a preliminary evaluation. The technique used to compute the transition matrix is fully described. The evaluation suggests that the ordered subsets algorithm converges much faster than SAGE, but that it stops short of the optimal solution.
引用
收藏
页码:1594 / 1598
页数:5
相关论文
共 50 条
  • [1] Performance of a fast maximum likelihood algorithm for fully 3D pet reconstruction
    Matej, S
    Browne, JA
    [J]. THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 1996, 4 : 297 - 315
  • [2] 3D PET image reconstruction based on the maximum likelihood estimation method (MLEM) algorithm
    Slomski, Artur
    Rudy, Zbigniew
    Bednarski, Tomasz
    Bialas, Piotr
    Czerwinski, Eryk
    Kaplon, Lukasz
    Kochanowski, Andrzej
    Korcyl, Grzegorz
    Kowal, Jakub
    Kowalski, Pawel
    Kozik, Tomasz
    Krzemien, Wojciech
    Molenda, Marcin
    Moskal, Pawel
    Niedzwiecki, Szymon
    Palka, Marek
    Pawlik, Monika
    Raczynski, Lech
    Salabura, Piotr
    Gupta-Sharma, Neha
    Silarski, Michal
    Smyrski, Jerzy
    Strzelecki, Adam
    Wislicki, Wojciech
    Zielinski, Marcin
    Zon, Natalia
    [J]. BIO-ALGORITHMS AND MED-SYSTEMS, 2014, 10 (01) : 1 - 7
  • [3] Impact of Scatter Modeling Error on 3D Maximum Likelihood Reconstruction in PET
    Tamal, M.
    Markiewicz, P. J.
    Julyan, P. J.
    Hastings, D. L.
    Reader, A. J.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3154 - 3158
  • [4] Fully 3D GPU PET reconstruction
    Herraiz, J. L.
    Espana, S.
    Cal-Gonzalez, J.
    Vaquero, J. J.
    Desco, M.
    Udias, J. M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S169 - S171
  • [5] Application of the 3D row action maximum likelihood algorithm to clinical PET imaging
    Daube-Witherspoon, ME
    Matej, S
    Karp, JS
    Lewitt, RM
    [J]. 1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1676 - 1680
  • [6] Ultrafast Preconditioned Conjugate Gradient OSEM Algorithm for Fully 3D PET Reconstruction
    Hong, I. K.
    Burbar, Z.
    Michel, C.
    Leahy, R.
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2418 - +
  • [7] Regularization design in penalized maximum-likelihood image reconstruction for lesion detection in 3D PET
    Yang, Li
    Zhou, Jian
    Ferrero, Andrea
    Badawi, Ramsey D.
    Qi, Jinyi
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (02): : 403 - 419
  • [8] Optimization of a fully 3D single scatter simulation algorithm for 3D PET
    Accorsi, R
    Adam, LE
    Werner, ME
    Karp, JS
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12): : 2577 - 2598
  • [9] Filtering of 3D point clouds using maximum likelihood algorithm
    Salah, Mahmoud
    Farhan, Magda
    Basha, Ali
    Sherif, Mohamed
    [J]. DISCOVER APPLIED SCIENCES, 2024, 6 (08)
  • [10] Parallelization of a fully 3D CT iterative reconstruction algorithm
    Keesing, Daniel B.
    O'Sullivan, Joseph A.
    Politte, David G.
    Whiting, Bruce R.
    [J]. 2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 1240 - +