Baseline heart rate-adjusted electrocardiographic triggering for coronary artery electron-beam CT angiography

被引:4
|
作者
Lu, B
Zhuang, N
Mao, SS
Child, J
Carson, S
Budoff, MJ
机构
[1] Peking Union Med Coll, Dept Radiol, Cardiovasc Inst, Beijing 100037, Peoples R China
[2] Peking Union Med Coll, FuWaiu Hosp, Beijing 100037, Peoples R China
[3] Chinese Acad Med Sci, Beijing 100037, Peoples R China
[4] Univ Calif Los Angeles, Harbor Med Ctr, Dept Med, Div Cardiol, Torrance, CA 90509 USA
[5] St Johns Cardiovasc Res Ctr, Torrance, CA 90509 USA
关键词
computed tomography (CT); angiography; electron beam; image quality; coronary vessels; stenosis or obstruction;
D O I
10.1148/radiol.2332030953
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Conventional electrocardiographic (ECG) triggering (group 1, 53 patients) was compared with baseline heart rate-adjusted ECG triggering (group 2, 54 patients) for coronary artery electron-beam computed tomographic (CT) angiography. CT angiographic data sets were compared blindly with conventional angiograms according to segment. Nonassessability of coronary artery segments was reduced from 35% in group 1 to 13% in group 2 (P <.001). More motionfree coronary artery images were obtained in group 2 than in group 1, especially in the right coronary artery (95% vs 67%, P <.001). Overall sensitivity and specificity for luminal stenosis ( greater than or equal to 50%) were 69% and 82% (group 1) and 76% and 92% (group 2) (P >.05 and P <.001, respectively). Baseline heart rate-adjusted ECG triggering improves image quality at coronary artery CT angiography for detection of coronary artery disease. (C) RSNA, 2004.
引用
收藏
页码:590 / 595
页数:6
相关论文
共 50 条
  • [1] Accuracy of coronary artery dimensions with electron-beam CT angiography: Comparison of measurement methods
    Funabashi, N
    Rubin, GD
    Kobayashi, Y
    Shifrin, RY
    Wexler, L
    Perlroth, M
    [J]. RADIOLOGY, 1999, 213P : 269 - 269
  • [2] Electron-beam CT coronary angiography: Imaging characteristics in normal coronary arteries
    Chernoff, DM
    Ritchie, CJ
    Higgins, CB
    [J]. RADIOLOGY, 1996, 201 : 789 - 789
  • [3] Assessment of coronary artery stent patency by electron-beam CT
    Knollmann, FD
    Möller, J
    Gebert, A
    Bethge, C
    Felix, R
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (08) : 1341 - 1347
  • [4] Assessment of coronary artery stent patency by electron-beam CT
    Friedrich D. Knollmann
    Jörg Möller
    Axel Gebert
    Christian Bethge
    Roland Felix
    [J]. European Radiology, 2004, 14 : 1341 - 1347
  • [5] Coronary artery anomalies with a shunt: Evaluation with electron-beam CT
    Yoshimura, N
    Hamada, S
    Takamiya, M
    Kuribayashi, S
    Kimura, K
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (05) : 682 - 686
  • [6] Electron-beam CT angiography with three-dimensional reconstruction in the evaluation of coronary artery bypass grafts
    Dai, RP
    Zhang, SX
    Lu, B
    Cao, C
    He, S
    Bai, H
    Jing, BL
    [J]. ACADEMIC RADIOLOGY, 1998, 5 (12) : 863 - 867
  • [7] Comparison of non-invasive electron-beam and multislice CT angiography efficacy for detection of coronary artery stenosis
    Ustyuzhanin, D. V.
    Veselova, T. N.
    Sinitsyn, V. E.
    Matchin, Yu. G.
    Ternovoy, S. K.
    [J]. TERAPEVTICHESKII ARKHIV, 2008, 80 (04): : 12 - 15
  • [8] Effects of scanning and reconstruction parameters on image quality in electron-beam CT angiography: Coronary Artery Phantom Study
    Lu, B
    Dai, RP
    Bai, H
    He, S
    Jiang, SL
    Zhuang, N
    Budoff, MJ
    [J]. ACADEMIC RADIOLOGY, 2000, 7 (11) : 927 - 933
  • [9] Detection and quantification of coronary artery calcification with electron-beam and conventional CT
    Becker, CR
    Knez, A
    Jakobs, TF
    Aydemir, S
    Becker, A
    Schoepf, UJ
    Bruening, R
    Haberl, R
    Reiser, MF
    [J]. EUROPEAN RADIOLOGY, 1999, 9 (04) : 620 - 624
  • [10] Spiral versus electron-beam CT for coronary artery calcium scoring
    Goldin, JG
    Yoon, HC
    Greaser, LE
    Heinze, SB
    McNitt-Gray, MM
    Brown, MS
    Sayre, JW
    Emerick, AM
    Aberle, DR
    [J]. RADIOLOGY, 2001, 221 (01) : 213 - 221