Conventional electrocardiographic (ECG) triggering (group 1, 53 patients) was compared with baseline heart rate-adjusted ECG triggering (group 2, 54 patients) for coronary artery electron-beam computed tomographic (CT) angiography. CT angiographic data sets were compared blindly with conventional angiograms according to segment. Nonassessability of coronary artery segments was reduced from 35% in group 1 to 13% in group 2 (P <.001). More motionfree coronary artery images were obtained in group 2 than in group 1, especially in the right coronary artery (95% vs 67%, P <.001). Overall sensitivity and specificity for luminal stenosis ( greater than or equal to 50%) were 69% and 82% (group 1) and 76% and 92% (group 2) (P >.05 and P <.001, respectively). Baseline heart rate-adjusted ECG triggering improves image quality at coronary artery CT angiography for detection of coronary artery disease. (C) RSNA, 2004.
引用
收藏
页码:590 / 595
页数:6
相关论文
共 50 条
  • [41] Coronary calcification, detected by electron-beam CT, and cardiovascular disease
    Vliegenthart, R
    De Groot, JC
    Witteman, J
    Breteler, MM
    Hofman, A
    Oudkerk, M
    [J]. RADIOLOGY, 2001, 221 : 502 - 502
  • [42] Electron-beam CT in the noninvasive assessment of coronary stent patency
    Pump, H
    Moehlenkamp, S
    Sehnert, C
    Schimpf, SS
    Erbel, R
    Seibel, RMM
    Groenemeyer, DHW
    [J]. ACADEMIC RADIOLOGY, 1998, 5 (12) : 858 - 862
  • [43] RELIABILITY OF CORONARY CALCIUM QUANTIFICATION WITH ELECTRON-BEAM CT - REPLY
    KAUFMANN, RB
    BIELAK, LF
    MOLL, PP
    SHEEDY, PF
    BREEN, JF
    KELZENBERG, JR
    KRUGER, BL
    SCHWARTZ, RS
    [J]. RADIOLOGY, 1994, 193 (01) : 282 - 283
  • [44] Preview method for electron-beam CT scanning of the coronary arteries
    Bakhsheshi, H
    Mao, SS
    Budoff, MJ
    Bin, L
    Brundage, BH
    [J]. ACADEMIC RADIOLOGY, 2000, 7 (08) : 620 - 626
  • [45] Coronary arterial stent patency:: Assessment with electron-beam CT
    Pump, H
    Möhlenkamp, S
    Sehnert, CA
    Schimpf, SS
    Schmidt, A
    Erbel, R
    Grönemeyer, DHW
    Seibel, RMM
    [J]. RADIOLOGY, 2000, 214 (02) : 447 - 452
  • [46] Electron-beam computed tomography, coronary artery calcium, and evaluation of patients with coronary artery disease
    Fiorino, AS
    [J]. ANNALS OF INTERNAL MEDICINE, 1998, 128 (10) : 839 - 847
  • [47] Evaluation of electron beam CT coronary angiography in healthy subjects
    Chernoff, DM
    Ritchie, CJ
    Higgins, CB
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (01) : 93 - 99
  • [48] Non-invasive diagnosis of restenosis following coronary angioplasty by electron-beam CT - Comparison to coronary angiography in 50 patients
    Moshage, W
    Achenbach, S
    Bachmann, K
    [J]. RADIOLOGY, 1997, 205 : 1346 - 1346
  • [49] CORONARY CALCIUM VOLUME BY ELECTRON-BEAM CT QUANTIFIES CORONARY PLAQUE VOLUME
    RUMBERGER, JA
    SIMONS, DB
    EDWARDS, WD
    FITZPATRICK, LA
    SHEEDY, PF
    SCHWARTZ, RS
    [J]. CIRCULATION, 1994, 90 (04) : 300 - 300
  • [50] Electron-beam CT scan designed to prevent heart disease
    Anon
    [J]. Biomedical Instrumentation and Technology, 2003, 37 (05):