Baseline heart rate-adjusted electrocardiographic triggering for coronary artery electron-beam CT angiography

被引:4
|
作者
Lu, B
Zhuang, N
Mao, SS
Child, J
Carson, S
Budoff, MJ
机构
[1] Peking Union Med Coll, Dept Radiol, Cardiovasc Inst, Beijing 100037, Peoples R China
[2] Peking Union Med Coll, FuWaiu Hosp, Beijing 100037, Peoples R China
[3] Chinese Acad Med Sci, Beijing 100037, Peoples R China
[4] Univ Calif Los Angeles, Harbor Med Ctr, Dept Med, Div Cardiol, Torrance, CA 90509 USA
[5] St Johns Cardiovasc Res Ctr, Torrance, CA 90509 USA
关键词
computed tomography (CT); angiography; electron beam; image quality; coronary vessels; stenosis or obstruction;
D O I
10.1148/radiol.2332030953
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Conventional electrocardiographic (ECG) triggering (group 1, 53 patients) was compared with baseline heart rate-adjusted ECG triggering (group 2, 54 patients) for coronary artery electron-beam computed tomographic (CT) angiography. CT angiographic data sets were compared blindly with conventional angiograms according to segment. Nonassessability of coronary artery segments was reduced from 35% in group 1 to 13% in group 2 (P <.001). More motionfree coronary artery images were obtained in group 2 than in group 1, especially in the right coronary artery (95% vs 67%, P <.001). Overall sensitivity and specificity for luminal stenosis ( greater than or equal to 50%) were 69% and 82% (group 1) and 76% and 92% (group 2) (P >.05 and P <.001, respectively). Baseline heart rate-adjusted ECG triggering improves image quality at coronary artery CT angiography for detection of coronary artery disease. (C) RSNA, 2004.
引用
收藏
页码:590 / 595
页数:6
相关论文
共 50 条
  • [31] AN ELECTRON-BEAM CT APPROACH FOR TRANSVENOUS CORONARY ARTERIOGRAPHY
    THOMAS, PJ
    MCCOLLOUGH, CH
    RITMAN, EL
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (03) : 383 - 389
  • [32] The effect of lead selection on traditional and heart rate-adjusted ST segment analysis in the detection of coronary artery disease during exercise testing
    Viik, J
    Lehtinen, R
    Turjanmaa, V
    Niemela, K
    Malmivuo, J
    [J]. AMERICAN HEART JOURNAL, 1997, 134 (03) : 488 - 494
  • [33] Intravenous electron-beam CT based angiography: Segmental analysis of significant disease in the major coronary arteries
    Schmermund, A
    Rensing, BJ
    Sheedy, PF
    Bell, MR
    Rumberger, JA
    [J]. CIRCULATION, 1997, 96 (08) : 1705 - 1705
  • [34] CLINICAL-SIGNIFICANCE OF SIMPLE HEART RATE-ADJUSTED ST SEGMENT DEPRESSION IN SUPINE LEG EXERCISE IN THE DIAGNOSIS OF CORONARY-ARTERY DISEASE
    WATANABE, M
    YOKOTA, M
    MIYAHARA, T
    SAITO, F
    MATSUNAMI, T
    KODAMA, Y
    SAITO, H
    TAKEUCHI, J
    [J]. AMERICAN HEART JOURNAL, 1990, 120 (05) : 1102 - 1110
  • [35] Coronary artery stenoses: Assessment with contrast-enhanced electron-beam CT and axial reconstructions
    Reddy, GP
    Chernoff, DM
    Adams, JR
    Higgins, CB
    [J]. RADIOLOGY, 1998, 208 (01) : 167 - 172
  • [36] Assessment of coronary artery stenoses with contrast-enhanced electron-beam CT and axial reconstructions
    Reddy, GP
    Chernoff, DM
    Siripornpitak, S
    Adams, JR
    Outtrim, RA
    Higgins, CB
    [J]. RADIOLOGY, 1997, 205 : 1345 - 1345
  • [37] Optimal electrocardiographically triggered phase for reducing motion artifact at electron-beam CT in the coronary artery
    He, S
    Dai, RP
    Chen, Y
    Bai, H
    [J]. ACADEMIC RADIOLOGY, 2001, 8 (01) : 48 - 56
  • [38] Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method
    Callister, TQ
    Cooil, B
    Raya, SP
    Lippolis, NJ
    Russo, DJ
    Raggi, P
    [J]. RADIOLOGY, 1998, 208 (03) : 807 - 814
  • [39] Comparison of dual-source and electron-beam CT for the assessment of coronary artery calcium scoring
    Reinsch, N.
    Mahabadi, A. A.
    Lehmann, N.
    Moehlenkamp, S.
    Hoefs, C.
    Sievers, B.
    Budde, T.
    Seibel, R.
    Joeckel, K-H
    Erbel, R.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1015): : E300 - E306
  • [40] Coronary artery calcium quantification at multi-detector row helical CT versus electron-beam CT
    Stanford, W
    Thompson, BH
    Burns, TL
    Heery, SD
    Burr, MC
    [J]. RADIOLOGY, 2004, 230 (02) : 397 - 402