Spiral versus electron-beam CT for coronary artery calcium scoring

被引:54
|
作者
Goldin, JG
Yoon, HC
Greaser, LE
Heinze, SB
McNitt-Gray, MM
Brown, MS
Sayre, JW
Emerick, AM
Aberle, DR
机构
[1] Univ Calif Los Angeles, Sch Med, Dept Radiol Sci, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, Sch Med, Dept Radiol Phys, Los Angeles, CA 90095 USA
[3] Univ Calif Los Angeles, Sch Med, Dept Biomath, Los Angeles, CA 90095 USA
[4] Univ Utah, Sch Med, Dept Radiol, Salt Lake City, UT USA
[5] Finch Univ Hlth Sci Chicago Med Sch, N Chicago, IL 60064 USA
关键词
calcium; computed tomography (CT); electron beam; coronary vessels; CT; stenosis or obstruction;
D O I
10.1148/radiol.2211001038
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine differences in coronary artery calcium detection, quantification, and reproducibility, as measured at electron-beam computed tomography (CT) and subsecond spiral CT with retrospective electrocardiogram gating in an asymptomatic adult population. MATERIALS AND METHODS: Seventy subjects asymptomatic for coronary heart disease underwent both electron-beam CT and subsecond spiral CT. In all subjects, two images each were obtained with both scanners. Two experienced readers using three different algorithms scored each of the four scans: one score for the electron-beam CT images and two scores for the spiral CT images. RESULTS: With a 130-HU threshold for the quantification of calcium, there were no significant differences in interscan and interobserver variation in calcium scores between the electron-beam CT and spiral CT images. There was greater interobserver (P < .001) and interscan (P < .03) variation in scores when a 90-HU threshold was used for spiral CT images. With a 130-HU threshold, when calcium scores were used for clinical risk stratification, there was a significant difference between the results obtained with electron-beam CT and those obtained with spiral CT (P < .05). CONCLUSION: Spiral CT has not yet proved to be a feasible alternative to electron-beam CT for coronary artery calcium quantification. There are systematic differences between calcium scores obtained with single-detector array subsecond spiral CT and those obtained with electron-beam CT.
引用
收藏
页码:213 / 221
页数:9
相关论文
共 50 条
  • [1] Comparison of dual-source and electron-beam CT for the assessment of coronary artery calcium scoring
    Reinsch, N.
    Mahabadi, A. A.
    Lehmann, N.
    Moehlenkamp, S.
    Hoefs, C.
    Sievers, B.
    Budde, T.
    Seibel, R.
    Joeckel, K-H
    Erbel, R.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1015): : E300 - E306
  • [2] Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method
    Callister, TQ
    Cooil, B
    Raya, SP
    Lippolis, NJ
    Russo, DJ
    Raggi, P
    [J]. RADIOLOGY, 1998, 208 (03) : 807 - 814
  • [3] Coronary artery calcium quantification at multi-detector row helical CT versus electron-beam CT
    Stanford, W
    Thompson, BH
    Burns, TL
    Heery, SD
    Burr, MC
    [J]. RADIOLOGY, 2004, 230 (02) : 397 - 402
  • [4] Causes of interscan variability of coronary artery calcium measurements at electron-beam CT
    Lu, B
    Budoff, MJ
    Zhuang, N
    Child, J
    Bakhsheshi, H
    Carson, S
    Mao, SS
    [J]. ACADEMIC RADIOLOGY, 2002, 9 (06) : 654 - 661
  • [5] HELICAL VERSUS ELECTRON-BEAM CT IN ASSESSMENT OF CORONARY-ARTERY CALCIFICATION
    BASKIN, KM
    STANFORD, W
    THOMPSON, BH
    TAJIK, J
    HEERY, SD
    HOFFMAN, EA
    [J]. RADIOLOGY, 1995, 197 : 182 - 182
  • [6] Coronary calcification at electron-beam CT: Effect of section thickness on calcium scoring in vitro and in vivo
    Vliegenthart, R
    Song, B
    Hofman, A
    Witteman, JCM
    Oudkerk, M
    [J]. RADIOLOGY, 2003, 229 (02) : 520 - 525
  • [7] Electron-beam CT: The effect of using a correction function on coronary artery calcium quantitation
    Greaser, LE
    Yoon, HC
    Mather, RT
    McNitt-Gray, M
    Goldin, JG
    [J]. ACADEMIC RADIOLOGY, 1999, 6 (01) : 40 - 48
  • [8] Calcium scoring of the coronary artery by electron beam CT: How to apply an individual attenuation threshold
    Raggi, P
    Callister, TQ
    Cooil, B
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (02) : 497 - 502
  • [9] CT imaging of the abdomen: Electron-beam versus spiral and sequential scanning
    Schoepf, UO
    Bruening, RD
    Becker, CR
    Rogalla, P
    Georgi, M
    Reiser, MF
    [J]. RADIOLOGY, 1998, 209P : 409 - 409
  • [10] RELIABILITY OF CORONARY CALCIUM QUANTIFICATION WITH ELECTRON-BEAM CT - REPLY
    KAUFMANN, RB
    BIELAK, LF
    MOLL, PP
    SHEEDY, PF
    BREEN, JF
    KELZENBERG, JR
    KRUGER, BL
    SCHWARTZ, RS
    [J]. RADIOLOGY, 1994, 193 (01) : 282 - 283