Anterior chamber width measurement by high speed optical coherence tomography

被引:190
|
作者
Goldsmith, JA
Li, Y
Chalita, MR
Westphal, V
Patil, CA
Rollins, AM
Izatt, JA
Huang, D
机构
[1] Cleveland Clin Fdn, Cole Eye Inst, Cleveland, OH 44195 USA
[2] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[3] Case Western Reserve Univ, Dept Med, Cleveland, OH 44106 USA
[4] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[5] Cleveland Clin Fdn, Lerner Res Inst, Dept Biomed Engn, Cleveland, OH 44195 USA
关键词
D O I
10.1016/j.ophtha.2004.09.019
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To measure anterior chamber (AC) width and other dimensions relevant to the sizing of phakic intraocular lenses (IOLs) with a high-speed optical coherence tomography (OCT) system. Design: Cross-sectional observational study. Participants: Both eyes of 20 normal volunteers. Methods: A novel high-speed (4000 axial scans/second) OCT prototype was developed for anterior segment scanning. The system uses long wavelength (1310 nm) for deeper angle penetration, rectangular scanning for undistorted imaging, and short image acquisition time (0.125 seconds) to reduce motion error. Three horizontal cross-sectional OCT images (15.5 mm wide and 6 mm deep) of the anterior segment were obtained from each eye with real-time image display to guide centration on the corneal apex. Image processing software was developed to correct for image warping resulting from index transitions. Anterior chamber dimensions were measured using computer calipers by 3 expert raters (ophthalmologists). Analysis of variance was used to determine interrater, interimage, right versus left eye, and intersubject standard deviation (SD) of OCT measurements. Main Outcome Measures: Anterior chamber width (recess to recess), AC depth, and crystalline lens vault as measured by OCT; external white-to-white (WTW) corneal diameter (CD) as measured by Holladay-Godwin gauge. Results: The mean AC width was 12.53+/-0.47 mm (intereye SD), and the mean corneal diameter was 11.78+/-0.57 mm. Optical coherence tomography measurement of AC width has good repeatability from image to image (SD, 0.134 mm), but there was significant difference between raters (SD, 0.215 mm). Estimation of AC width from WTW CD by linear regression was relatively inaccurate (residual SD, 0.41 mm). The mean AC depth was 2.99+/-0.323 mm (intereye SD), with repeatability of less than 0.001 mm (interimage SD), and the mean crystalline lens vault was 0.39+/-0.27 mm with 0.023 mm repeatability. Conclusions: Reproducible OCT AC biometry was demonstrated using a high-speed OCT prototype. Further improvement in reproducibility may be achieved by automating the measurements with a computer. Direct OCT AC width measurement may improve sizing of angle-supported AC IOLs over conventional estimation by WTW CD. The measurement of AC depth and lens vault also may be useful for other types of phakic AC IOLs. (C) 2005 by the American Academy of Ophthalmology.
引用
收藏
页码:238 / 244
页数:7
相关论文
共 50 条
  • [41] Effect of Hemodialysis on Anterior Chamber Angle Measured by Anterior Segment Optical Coherence Tomography
    Shin, Yong Un
    Kim, Ji Hong
    Cho, Heeyoon
    Kim, Dae Sung
    Yi, Joo-Hark
    Han, Sang-Woong
    Seong, Mincheol
    JOURNAL OF OPHTHALMOLOGY, 2019, 2019
  • [42] Anterior optical coherence tomography: a non-contact technique for anterior chamber evaluation
    Jens Dawczynski
    Ekkehart Koenigsdoerffer
    Regine Augsten
    Juergen Strobel
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2007, 245 : 423 - 425
  • [43] High-speed, swept-source optical coherence tomography: a 3-dimensional view of anterior chamber angle recession
    Kawana, Keisuke
    Yasuno, Yoshiaki
    Yatagai, Toyohiko
    Oshika, Tetsuro
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (06): : 684 - 685
  • [44] Measurement of the internal diameter and depth of the anterior chamber: IOLMaster versus anterior chamber optical coherence tomographer
    Baikoff, G
    Jodai, HJ
    Bourgeon, G
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09): : 1722 - 1728
  • [45] High speed low coherence interferometer for optical coherence tomography
    Hauger, C
    Wörz, M
    Hellmuth, T
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICAL APPLICATIONS VI, 2002, 4619 : 1 - 9
  • [46] Displacement between anterior chamber width obtained by swept-source anterior segment optical coherence tomography and white-to-white distance
    Taechameekietichai, Teerajet
    Nguyen, Anwell
    Chansangpetch, Sunee
    Lin, Shan C.
    PLOS ONE, 2021, 16 (05):
  • [47] Anterior segment optical coherence tomography measurement of anterior chamber depth and angle changes after phacoemulsification and intralocular lens implantation
    Kucumen, Raciha Beril
    Yenerel, Nursal Melda
    Gorgun, Ebru
    Kulacoglu, Destan Nil
    Dinc, Umut Asli
    Alimgil, Murat Levent
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (10): : 1694 - 1698
  • [48] Anterior chamber angle measurement with anterior segment optical coherence tomography: A comparison between slit lamp OCT and Visante OCT
    Leung, Christopher Kai-Shun
    Li, Haitao
    Weinreb, Robert Neal
    Liu, Jing
    Cheung, Carol Yim Lui
    Lai, Ricky Yiu Kwong
    Pang, Chi Pui
    Lam, Dennis Shun Chiu
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (08) : 3469 - 3474
  • [49] Anterior Chamber Angle Imaging with Swept-Source Optical Coherence Tomography: An Investigation on Variability of Angle Measurement
    Liu, Shu
    Yu, Marco
    Ye, Cong
    Lam, Dennis S. C.
    Leung, Christopher Kai-shun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (12) : 8598 - 8603
  • [50] Modeling of gonioscopic anterior chamber angle grades based on anterior segment optical coherence tomography
    Dai, Yingying
    Zhang, Shaodan
    Shen, Meixiao
    Zhou, Yuheng
    Wang, Mengyi
    Ye, Jie
    Zhu, Dexi
    EYE AND VISION, 2020, 7 (01)