Anterior chamber width measurement by high speed optical coherence tomography

被引:190
|
作者
Goldsmith, JA
Li, Y
Chalita, MR
Westphal, V
Patil, CA
Rollins, AM
Izatt, JA
Huang, D
机构
[1] Cleveland Clin Fdn, Cole Eye Inst, Cleveland, OH 44195 USA
[2] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[3] Case Western Reserve Univ, Dept Med, Cleveland, OH 44106 USA
[4] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[5] Cleveland Clin Fdn, Lerner Res Inst, Dept Biomed Engn, Cleveland, OH 44195 USA
关键词
D O I
10.1016/j.ophtha.2004.09.019
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To measure anterior chamber (AC) width and other dimensions relevant to the sizing of phakic intraocular lenses (IOLs) with a high-speed optical coherence tomography (OCT) system. Design: Cross-sectional observational study. Participants: Both eyes of 20 normal volunteers. Methods: A novel high-speed (4000 axial scans/second) OCT prototype was developed for anterior segment scanning. The system uses long wavelength (1310 nm) for deeper angle penetration, rectangular scanning for undistorted imaging, and short image acquisition time (0.125 seconds) to reduce motion error. Three horizontal cross-sectional OCT images (15.5 mm wide and 6 mm deep) of the anterior segment were obtained from each eye with real-time image display to guide centration on the corneal apex. Image processing software was developed to correct for image warping resulting from index transitions. Anterior chamber dimensions were measured using computer calipers by 3 expert raters (ophthalmologists). Analysis of variance was used to determine interrater, interimage, right versus left eye, and intersubject standard deviation (SD) of OCT measurements. Main Outcome Measures: Anterior chamber width (recess to recess), AC depth, and crystalline lens vault as measured by OCT; external white-to-white (WTW) corneal diameter (CD) as measured by Holladay-Godwin gauge. Results: The mean AC width was 12.53+/-0.47 mm (intereye SD), and the mean corneal diameter was 11.78+/-0.57 mm. Optical coherence tomography measurement of AC width has good repeatability from image to image (SD, 0.134 mm), but there was significant difference between raters (SD, 0.215 mm). Estimation of AC width from WTW CD by linear regression was relatively inaccurate (residual SD, 0.41 mm). The mean AC depth was 2.99+/-0.323 mm (intereye SD), with repeatability of less than 0.001 mm (interimage SD), and the mean crystalline lens vault was 0.39+/-0.27 mm with 0.023 mm repeatability. Conclusions: Reproducible OCT AC biometry was demonstrated using a high-speed OCT prototype. Further improvement in reproducibility may be achieved by automating the measurements with a computer. Direct OCT AC width measurement may improve sizing of angle-supported AC IOLs over conventional estimation by WTW CD. The measurement of AC depth and lens vault also may be useful for other types of phakic AC IOLs. (C) 2005 by the American Academy of Ophthalmology.
引用
收藏
页码:238 / 244
页数:7
相关论文
共 50 条
  • [31] High-speed optical coherence tomography of anterior segment surgical anatomy and pathology
    Huang, D
    Chalita, MR
    Li, Y
    Lowder, CY
    Meisler, DM
    Rollins, AM
    Izatt, JA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U141 - U141
  • [32] Investigation of the variability of anterior chamber scan protocol with Cirrus high definition optical coherence tomography
    Tun, Tin A.
    Tan, Shayne S.
    Atalay, Eray
    Verma, Sushma
    Nongpiur, Monisha E.
    Baskaran, Mani
    Aung, Tin
    Husain, Rahat
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 45 (05): : 464 - 471
  • [33] Visualization of anterior chamber angle dynamics using optical coherence tomography
    Leung, CKS
    Chan, WM
    Ko, CY
    Chui, SI
    Woo, J
    Tsang, MK
    Tse, RKK
    OPHTHALMOLOGY, 2005, 112 (06) : 980 - 984
  • [34] Anterior chamber angle analysis using optical coherence tomography.
    Mori, K
    Kawasaki, S
    Naruse, S
    Kobayashi, L
    Kinoshita, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S285 - S285
  • [35] Analysis of Anterior Chamber Inflammation by Spectral Domain Optical Coherence Tomography
    Sharma, Sumit
    Baynes, Kimberly
    Kaiser, Peter
    Lowder, Careen
    Srivastava, Sunil
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [36] High speed scanning optical coherence tomography
    Song, GJ
    Jacques, SL
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT, 2002, 4916 : 259 - 265
  • [37] Anatomical Changes of the Anterior Chamber Angle With Anterior-Segment Optical Coherence Tomography
    Liu, Lance
    ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (12) : 1682 - 1686
  • [38] Reproducibility of anterior chamber angle measurements obtained with anterior segment optical coherence tomography
    Radhakrishnan, Sunita
    See, Jovina
    Smith, Scott D.
    Nolan, Winifred P.
    Ce, Zheng
    Friedman, David S.
    Huang, David
    Li, Yan
    Aung, Tin
    Chew, Paul T. K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (08) : 3683 - 3688
  • [39] Anterior optical coherence tomography: a non-contact technique for anterior chamber evaluation
    Dawczynski, Jens
    Koenigsdoerffer, Ekkehart
    Augsten, Regine
    Strobel, Juergen
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (03) : 423 - 425
  • [40] Analysis of Anterior Chamber Inflammation By Anterior Segment Spectral Domain Optical Coherence Tomography
    Srivastava, Sunil K.
    Sharma, Sumit
    Baynes, Kimberly
    Lowder, Careen Y.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)