Anterior chamber width measurement by high speed optical coherence tomography

被引:190
|
作者
Goldsmith, JA
Li, Y
Chalita, MR
Westphal, V
Patil, CA
Rollins, AM
Izatt, JA
Huang, D
机构
[1] Cleveland Clin Fdn, Cole Eye Inst, Cleveland, OH 44195 USA
[2] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[3] Case Western Reserve Univ, Dept Med, Cleveland, OH 44106 USA
[4] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[5] Cleveland Clin Fdn, Lerner Res Inst, Dept Biomed Engn, Cleveland, OH 44195 USA
关键词
D O I
10.1016/j.ophtha.2004.09.019
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To measure anterior chamber (AC) width and other dimensions relevant to the sizing of phakic intraocular lenses (IOLs) with a high-speed optical coherence tomography (OCT) system. Design: Cross-sectional observational study. Participants: Both eyes of 20 normal volunteers. Methods: A novel high-speed (4000 axial scans/second) OCT prototype was developed for anterior segment scanning. The system uses long wavelength (1310 nm) for deeper angle penetration, rectangular scanning for undistorted imaging, and short image acquisition time (0.125 seconds) to reduce motion error. Three horizontal cross-sectional OCT images (15.5 mm wide and 6 mm deep) of the anterior segment were obtained from each eye with real-time image display to guide centration on the corneal apex. Image processing software was developed to correct for image warping resulting from index transitions. Anterior chamber dimensions were measured using computer calipers by 3 expert raters (ophthalmologists). Analysis of variance was used to determine interrater, interimage, right versus left eye, and intersubject standard deviation (SD) of OCT measurements. Main Outcome Measures: Anterior chamber width (recess to recess), AC depth, and crystalline lens vault as measured by OCT; external white-to-white (WTW) corneal diameter (CD) as measured by Holladay-Godwin gauge. Results: The mean AC width was 12.53+/-0.47 mm (intereye SD), and the mean corneal diameter was 11.78+/-0.57 mm. Optical coherence tomography measurement of AC width has good repeatability from image to image (SD, 0.134 mm), but there was significant difference between raters (SD, 0.215 mm). Estimation of AC width from WTW CD by linear regression was relatively inaccurate (residual SD, 0.41 mm). The mean AC depth was 2.99+/-0.323 mm (intereye SD), with repeatability of less than 0.001 mm (interimage SD), and the mean crystalline lens vault was 0.39+/-0.27 mm with 0.023 mm repeatability. Conclusions: Reproducible OCT AC biometry was demonstrated using a high-speed OCT prototype. Further improvement in reproducibility may be achieved by automating the measurements with a computer. Direct OCT AC width measurement may improve sizing of angle-supported AC IOLs over conventional estimation by WTW CD. The measurement of AC depth and lens vault also may be useful for other types of phakic AC IOLs. (C) 2005 by the American Academy of Ophthalmology.
引用
收藏
页码:238 / 244
页数:7
相关论文
共 50 条
  • [1] Anterior chamber width measurement by optical coherence tomography
    Goldsmith, JA
    Li, Y
    Chalita, MR
    Westfall, V
    Patel, C
    Rollins, AM
    Izatt, J
    Huang, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U285 - U285
  • [2] Biometry of the anterior chamber with high-speed optical coherence tomography
    Radhakrishnan, S
    Netto, MV
    Li, Y
    Chalita, MR
    Huang, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U927 - U927
  • [3] Anterior chamber cell grading with high-speed optical coherence tomography
    Lowder, CY
    Li, Y
    Perez, VL
    Huang, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U118 - U118
  • [4] Automated anterior chamber biometry with high-speed optical coherence tomography
    Li, Y
    Chalita, MR
    Goldsmith, J
    Westphal, V
    Bower, BA
    Shekhar, R
    Rollins, AM
    Izatt, JA
    Huang, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U285 - U285
  • [5] Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography
    Li, Haitao
    Leung, Christopher Kai Shun
    Cheung, Carol Yim Lui
    Wong, Lee
    Pang, Chi Pui
    Weinreb, Robert Neal
    Lam, Dennis Shun Chiu
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (11) : 1490 - 1492
  • [6] Anterior chamber angle measurement with optical coherence tomography:: Intraobserver and interobserver variability
    Mueller, Maya
    Dahmen, Gerlinde
    Poerksen, Erk
    Geerling, Gerd
    Laqua, Horst
    Ziegler, Andreas
    Hoerauf, Hans
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11): : 1803 - 1808
  • [7] Measurement of anterior segment anatomy during accommodation with high-speed optical coherence tomography
    Gupta, PC
    Chalita, MR
    Li, Y
    Netto, MV
    Huang, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U414 - U414
  • [8] Measurement of anterior segment anatomy during accommodation with high-speed optical coherence tomography
    Gupta, PC
    Chalita, MR
    Li, Y
    Netto, MV
    Huang, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [9] Measurement of anterior chamber volume with rotating scheimpflug camera and anterior segment optical coherence tomography
    Fu Jing
    Li Shu-ning
    Wang Xiao-zhen
    Wu Ge-wei
    Mu Da-peng
    Wang Jian
    Wang Ning-li
    CHINESE MEDICAL JOURNAL, 2010, 123 (02) : 203 - 207
  • [10] Measurement of anterior chamber volume with rotating scheimpflug camera and anterior segment optical coherence tomography
    FU Jing LI Shuning WANG Xiaozhen WU Gewei MU Dapeng WANG Jian and WANG Ningli Beijing Tongren Eye Center Beijing Tongren Hospital Capital Medical University
    Beijing Ophthalmology and Visual Science Key Lab Beijing China Department of Ophthalmology Beijing Shijingshan Hospital Beijing China Department of Ophthalmology Beijing Tiantan Hospital Capital Medical University Beijing China
    中华医学杂志(英文版), 2010, (02) : 203 - 207