PURPOSE: To assess intraobserver and interobserver variability of anterior segment optical coherence tomography (AS-OCT) as an objective diagnostic tool to quantify the anterior chamber angle and opening width. SETTING: University Eye Clinic, Lubeck, Germany. METHODS: The anterior chamber angle and opening width were assessed in 18 eyes of 9 healthy volunteers by 2 observers. Intraobserver reproducibility was evaluated by calculating an intraclass correlation coefficient (ICC) in a mixed model. Each observer had a separate model using information from 5 scans. Interobserver variability was determined by Bland-Altman analysis. The ICC was calculated in a mixed model using a residual maximum likelihood method. The results of 3 and 5 repeated scans were evaluated to indicate the change to 1 measurement application. RESULTS: The mean anterior chamber angle measurement was 35.9 degrees +/-5.7 (SD) for observer A and 36.2 +/- 5.7 degrees for observer B. The ICC was 0.94 and 0.91, respectively. The mean opening width was 315 +/- 62 mu m for observer A and 317 +/- 60 mu m for observer B. The ICC was 0.97 and 0.93, respectively. Interobserver comparisons showed a mean difference between anterior chamber angle measurements of -0.27 +/- 1.6 degrees, a limit of agreement (LOA) interval from -3.52 to 2.98 degrees, and an ICC estimate of 0.96. The mean difference in opening width measurements was 2.40 +/- 12.40 mu m, the LOA from -27.20 to 22.40 mu m, and the estimated ICC 0.96. Using I instead of the mean of 5 measurements, the LOA range increased by 3.46 degrees for the anterior chamber angle and 30.0 mu m for the opening width. CONCLUSION: Anterior chamber angle and opening width measurements by OCT showed low intraobserver and interobserver variability, indicating OCT is a valuable technique for quantitative assessment that provides reproducible measurements and objective documentation by different examiners.
引用
收藏
页码:1803 / 1808
页数:6
相关论文
共 50 条
  • [1] Anterior Chamber Angle Imaging with Swept-Source Optical Coherence Tomography: An Investigation on Variability of Angle Measurement
    Liu, Shu
    Yu, Marco
    Ye, Cong
    Lam, Dennis S. C.
    Leung, Christopher Kai-shun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (12) : 8598 - 8603
  • [2] Optical coherence tomography imaging of coronary atherosclerosis is affected by intraobserver and interobserver variability
    Brown, Adam J.
    Jaworski, Catherine
    Corrigan, Joseph P.
    de Silva, Ramesh
    Bennett, Martin R.
    Mahmoudi, Michael
    Hoole, Stephen P.
    West, Nick E. J.
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2016, 17 (05) : 368 - 373
  • [3] Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography
    Li, Haitao
    Leung, Christopher Kai Shun
    Cheung, Carol Yim Lui
    Wong, Lee
    Pang, Chi Pui
    Weinreb, Robert Neal
    Lam, Dennis Shun Chiu
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (11) : 1490 - 1492
  • [4] Anterior chamber angle imaging with optical coherence tomography
    Leung, C. K-S
    Weinreb, R. N.
    EYE, 2011, 25 (03) : 261 - 267
  • [5] Anterior chamber angle imaging with optical coherence tomography
    C K-S Leung
    R N Weinreb
    Eye, 2011, 25 : 261 - 267
  • [6] Anterior chamber width measurement by optical coherence tomography
    Goldsmith, JA
    Li, Y
    Chalita, MR
    Westfall, V
    Patel, C
    Rollins, AM
    Izatt, J
    Huang, D
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U285 - U285
  • [7] Intraobserver variability in optical coherence tomography.
    Browning, DJ
    Fraser, CA
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 138 (03) : 477 - 479
  • [8] Evaluation of the Narrow Anterior Chamber Angle by Anterior Segment Optical Coherence Tomography
    Lan, Jie
    Sun, Dapeng
    Alabdulrasool, Khatoon
    Yusuf, Hassan Ebrahim
    Zhang, Lu
    OPHTHALMIC RESEARCH, 2017, 57 (02) : 87 - 91
  • [9] Reproducibility of Anterior Chamber Angle Measurements with Anterior Segment Optical Coherence Tomography
    Tan, Annelie N.
    Sauren, Loes D. C.
    de Brabander, John
    Berendschot, Tos T. J. M.
    Passos, Valeria Lima
    Webers, Carroll A. B.
    Nuijts, Rudy M. M. A.
    Beckers, Henny J. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (05) : 2095 - 2099
  • [10] Intraobserver and interobserver agreement in evaluating the anterior chamber angle configuration by ultrasound biomicroscopy
    Spaeth, GL
    AzuaraBlanco, A
    Araujo, SV
    Augsburger, JJ
    JOURNAL OF GLAUCOMA, 1997, 6 (01) : 13 - 17