Repeatability and agreement in optical biometry of a new swept-source optical coherence tomography-based biometer versus partial coherence interferometry and optical low-coherence reflectometry

被引:112
|
作者
Kunert, Kathleen S. [1 ]
Peter, Monika [2 ]
Blum, Marcus [1 ]
Haigis, Wolfgang [3 ]
Sekundo, Walter [4 ]
Schuetze, Juliane [5 ]
Bueehren, Tobias [2 ]
机构
[1] Helios Hosp Erfurt, Dept Ophthalmol, Nordhaeuserstr 74, D-99089 Erfurt, Germany
[2] Carl Zeiss Meditec AG, Jena, Germany
[3] Univ Wurzburg, Univ Eye Clin & Polyclin, D-97070 Wurzburg, Germany
[4] Univ Marburg, Dept Ophthalmol, Marburg, Germany
[5] Univ Appl Sci, Jena, Germany
来源
关键词
CENTRAL CORNEAL THICKNESS; LENS POWER CALCULATION; KERATOMETRY; REPRODUCIBILITY; DEVICE; PRECISION;
D O I
10.1016/j.jcrs.2015.07.039
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To estimate the repeatability of biometric parameters obtained with a new swept-source biometer and to compare the agreement with that of partial coherence interferometry (PCI) and optical low-coherence reflectometry (OLCR). SETTING: Department of Ophthalmology, Helios Hospital Erfurt, Erfurt, Julius-Maximilians University, Wurzburg, and Philipps University, Marburg, Germany. DESIGN: Prospective comparative multicenter clinical study. METHODS: Biometry was taken with the use of 3 different biometers: the IOLMaster 700 swept source biometer, the PCI-based IOLMaster 500, and the OCLR-based Lenstar LS 900. Axial length (AL), anterior chamber depth (ACD), and spherical equivalent (SE) were compared between swept source and PCI biometry and central corneal thickness (CCT) and lens thickness (LT) between swept-source and OLCR biometry. The repeatability of swept-source biometry was evaluated on the basis of 3 measurements captured for each patient. RESULTS: One hundred twenty cataract eyes were included in the study. The mean difference between swept-source and PCI biometry for AL, ACD, and SE measurements was 4 mu m +/- 25 (SD), 17 +/- 122 mu m, and -0.001 +/- 0.19 diopter (D), respectively. The mean difference between swept-source and OLCR biometry for LT and CCT measurements was 21 +/- 122 mu m and 0.15 +/- 4.51 mu m, respectively. Differences between swept-source biometry and the other devices distributed around zero without statistical significance. The standard deviation of repeatability for AL, ACD, LT, CCT, and SE was 8.8 mu m, 9.8 mu m, 2.3 mu m, 19.5 mu m, and 0.1 D, respectively. CONCLUSIONS: Swept-source biometry showed high repeatability performance for all biometric parameters. The agreement of AL, ACD, and SE between swept-source and PCI biometry as well as that of LT and CCT between swept-source and OLCR biometry was excellent. It remains to be validated whether high repeatability shown by swept-source biometry will result in better postoperative refractive outcomes.
引用
收藏
页码:76 / 83
页数:8
相关论文
共 50 条
  • [41] Comparison of Optical Low-Coherence Reflectometry and Swept-Source OCT-Based Biometry Devices in Dense Cataracts
    Vasavada, Shail A.
    Patel, Priyanka
    Vaishnav, Vineet R.
    Ashena, Zahra
    Srivastava, Samaresh
    Vasavada, Vaishali
    Nanavaty, Mayank A.
    JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (08) : 557 - 564
  • [42] Agreement in Biometric Parameters Between Swept-Source-Optical Coherence Tomography and Optical Low-Coherence Interferometry: Insights into Clinical Precision
    Munteanu, Mihnea
    Al Barri, Leila
    Stanca, Simona
    Mocanu, Valeria
    Rosca, Cosmin
    Balica, Nicolae-Constantin
    Stanca, Horia T.
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (05)
  • [43] Advances in swept-source optical coherence tomography and optical coherence tomography angiography
    Zheng, Fang
    Deng, Xiaofeng
    Zhang, Qi
    He, Jingliang
    Ye, Panpan
    Liu, Shan
    Li, Peng
    Zhou, Jian
    Fang, Xiaoyun
    ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2023, 3 (02): : 67 - 79
  • [44] Repeatability and Agreement of a Swept-Source Optical Coherence Tomography-Based Biometer IOLMaster 700 Versus a Scheimpflug Imaging-Based Biometer AL-Scan in Cataract Patients
    Chan, Tommy C. Y.
    Wan, Kelvin H.
    Tang, Fang Yao
    Wang, Yu Meng
    Yu, Marco
    Cheung, Carol
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2020, 46 (01): : 35 - 45
  • [45] Comparison of ocular biometric measurements between a new swept-source optical coherence tomography and a common optical low coherence reflectometry
    Rongrong Gao
    Hao Chen
    Giacomo Savini
    Yaxin Miao
    Xiaorui Wang
    Jing Yang
    Weiqi Zhao
    Qinmei Wang
    Jinhai Huang
    Scientific Reports, 7
  • [46] Comparison of ocular biometric measurements between a new swept-source optical coherence tomography and a common optical low coherence reflectometry
    Gao, Rongrong
    Chen, Hao
    Savini, Giacomo
    Miao, Yaxin
    Wang, Xiaorui
    Yang, Jing
    Zhao, Weiqi
    Wang, Qinmei
    Huang, Jinhai
    SCIENTIFIC REPORTS, 2017, 7
  • [47] Ocular biometry in dense cataracts: Comparison of partial-coherence interferometry, swept-source optical coherence tomography and immersion ultrasound
    Gonzalez-Godinez, Sara
    Saucedo-Urdapilleta, Roxana
    Mayorquin-Ruiz, Mariana
    Velasco-Barona, Cecilio
    Moragrega-Adame, Eduardo
    Dominguez-Varela, Irving A.
    Gonzalez-Salinas, Roberto
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (01) : 107 - +
  • [48] Agreement between a new optical low coherence reflectometry biometer and an anterior segment optical coherence tomographer
    Yiran Wang
    Ting Wan
    Luze Liu
    Yuyuan Xue
    Xinyao Chen
    Giacomo Savini
    Domenico Schiano-Lomoriello
    Xingtao Zhou
    Jinjin Yu
    Jinhai Huang
    Eye and Vision, 10
  • [49] Repeatability of 2 swept-source OCT biometers and 1 optical low-coherence reflectometry biometer (vol 47, pg 1302, 2021)
    Fisus, Andreea D.
    Hirnschall, Nino D.
    Ruiss, Manuel
    Pilwachs, Caroline
    Georgiev, Stefan
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (06): : 750 - 750
  • [50] Agreement between a new optical low coherence reflectometry biometer and an anterior segment optical coherence tomographer
    Wang, Yiran
    Wan, Ting
    Liu, Luze
    Xue, Yuyuan
    Chen, Xinyao
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Yu, Jinjin
    Huang, Jinhai
    EYE AND VISION, 2023, 10 (01)