Repeatability and agreement in optical biometry of a new swept-source optical coherence tomography-based biometer versus partial coherence interferometry and optical low-coherence reflectometry

被引:112
|
作者
Kunert, Kathleen S. [1 ]
Peter, Monika [2 ]
Blum, Marcus [1 ]
Haigis, Wolfgang [3 ]
Sekundo, Walter [4 ]
Schuetze, Juliane [5 ]
Bueehren, Tobias [2 ]
机构
[1] Helios Hosp Erfurt, Dept Ophthalmol, Nordhaeuserstr 74, D-99089 Erfurt, Germany
[2] Carl Zeiss Meditec AG, Jena, Germany
[3] Univ Wurzburg, Univ Eye Clin & Polyclin, D-97070 Wurzburg, Germany
[4] Univ Marburg, Dept Ophthalmol, Marburg, Germany
[5] Univ Appl Sci, Jena, Germany
来源
关键词
CENTRAL CORNEAL THICKNESS; LENS POWER CALCULATION; KERATOMETRY; REPRODUCIBILITY; DEVICE; PRECISION;
D O I
10.1016/j.jcrs.2015.07.039
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To estimate the repeatability of biometric parameters obtained with a new swept-source biometer and to compare the agreement with that of partial coherence interferometry (PCI) and optical low-coherence reflectometry (OLCR). SETTING: Department of Ophthalmology, Helios Hospital Erfurt, Erfurt, Julius-Maximilians University, Wurzburg, and Philipps University, Marburg, Germany. DESIGN: Prospective comparative multicenter clinical study. METHODS: Biometry was taken with the use of 3 different biometers: the IOLMaster 700 swept source biometer, the PCI-based IOLMaster 500, and the OCLR-based Lenstar LS 900. Axial length (AL), anterior chamber depth (ACD), and spherical equivalent (SE) were compared between swept source and PCI biometry and central corneal thickness (CCT) and lens thickness (LT) between swept-source and OLCR biometry. The repeatability of swept-source biometry was evaluated on the basis of 3 measurements captured for each patient. RESULTS: One hundred twenty cataract eyes were included in the study. The mean difference between swept-source and PCI biometry for AL, ACD, and SE measurements was 4 mu m +/- 25 (SD), 17 +/- 122 mu m, and -0.001 +/- 0.19 diopter (D), respectively. The mean difference between swept-source and OLCR biometry for LT and CCT measurements was 21 +/- 122 mu m and 0.15 +/- 4.51 mu m, respectively. Differences between swept-source biometry and the other devices distributed around zero without statistical significance. The standard deviation of repeatability for AL, ACD, LT, CCT, and SE was 8.8 mu m, 9.8 mu m, 2.3 mu m, 19.5 mu m, and 0.1 D, respectively. CONCLUSIONS: Swept-source biometry showed high repeatability performance for all biometric parameters. The agreement of AL, ACD, and SE between swept-source and PCI biometry as well as that of LT and CCT between swept-source and OLCR biometry was excellent. It remains to be validated whether high repeatability shown by swept-source biometry will result in better postoperative refractive outcomes.
引用
收藏
页码:76 / 83
页数:8
相关论文
共 50 条
  • [31] Scheimpflug-Placido topographer and optical low-coherence reflectometry biometer: Repeatability and agreement
    Chen, Wuhe
    McAlinden, Colm
    Pesudovs, Konrad
    Wang, Qinmei
    Lu, Fan
    Feng, Yifan
    Chen, Jie
    Huang, Jinhai
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (09): : 1626 - 1632
  • [32] Comparison of axial length using a new swept-source optical coherence tomography-based biometer - ARGOS with partial coherence interferometry- based biometer -IOLMaster among school children
    Hussaindeen, Jameel Rizwana
    Mariam, Ephrame G.
    Arunachalam, Sushil
    Bhavatharini, Ramakrishnan
    Gopalakrishnan, Aparna
    Narayanan, Anuradha
    Agarkar, Sumita
    Sivaraman, Viswanathan
    PLOS ONE, 2018, 13 (12):
  • [33] Agreement of predicted intraocular lens power using swept-source optical coherence tomography and partial coherence interferometry
    Tana-Sanz, Pedro
    Rodriguez-Carrillo, Maria Dolores
    Ruiz-Santos, Maria
    Montes-Mico, Robert
    Ruiz-Mesa, Ramon
    Tana-Rivero, Pedro
    EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (12) : 1219 - 1234
  • [34] Comparison of agreement and efficiency of a swept source-optical coherence tomography device and an optical low-coherence reflectometry device for biometry measurements during cataract evaluation
    Passi, Samuel F.
    Thompson, Atalie C.
    Gupta, Preeya K.
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 2245 - 2251
  • [35] Comparison of Clinical Outcomes between Swept-source Optical Coherence Tomography Biometer and Partial Coherence Interferometer
    Jang, Mirinae
    Lee, Hye Jin
    Lee, Sang-Yoon
    Kim, Jin Young
    Ma, Dae Joong
    Jeong, Jin Ho
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (08): : 905 - 910
  • [36] Comparison of Ocular Biometric Measurements Using New Swept-source Optical-coherence Tomography, Low-coherence Reflectometry, A-Scan Biometry, and Autokeratometry
    Cho, Jae Jin
    Bae, Gi Hyun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (04): : 287 - 295
  • [37] Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer
    Bao Shu
    Fangjun Bao
    Giacomo Savini
    Weicong Lu
    Ruixue Tu
    Haisi Chen
    Benhao Song
    Qinmei Wang
    Jinhai Huang
    Eye and Vision, 7
  • [38] Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer
    Shu, Bao
    Bao, Fangjun
    Savini, Giacomo
    Lu, Weicong
    Tu, Ruixue
    Chen, Haisi
    Song, Benhao
    Wang, Qinmei
    Huang, Jinhai
    EYE AND VISION, 2020, 7 (01)
  • [39] Biometry and intraocular power calculation using a swept-source optical coherence tomography: A repeatability and agreement study
    Hashemi, Hassan
    Miraftab, Mohammad
    Panahi, Parsa
    Asgari, Soheila
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (08) : 2845 - 2850
  • [40] Comparison of a new optical biometry with an optical low-coherence reflectometry for ocular biometry
    Guler, Emre
    Kulak, Ali Ender
    Totan, Yuksel
    Yuvarlak, Armagan
    Hepsen, Ibrahim Feyzi
    CONTACT LENS & ANTERIOR EYE, 2016, 39 (05): : 336 - 341