Repeatability and agreement in optical biometry of a new swept-source optical coherence tomography-based biometer versus partial coherence interferometry and optical low-coherence reflectometry

被引:112
|
作者
Kunert, Kathleen S. [1 ]
Peter, Monika [2 ]
Blum, Marcus [1 ]
Haigis, Wolfgang [3 ]
Sekundo, Walter [4 ]
Schuetze, Juliane [5 ]
Bueehren, Tobias [2 ]
机构
[1] Helios Hosp Erfurt, Dept Ophthalmol, Nordhaeuserstr 74, D-99089 Erfurt, Germany
[2] Carl Zeiss Meditec AG, Jena, Germany
[3] Univ Wurzburg, Univ Eye Clin & Polyclin, D-97070 Wurzburg, Germany
[4] Univ Marburg, Dept Ophthalmol, Marburg, Germany
[5] Univ Appl Sci, Jena, Germany
来源
关键词
CENTRAL CORNEAL THICKNESS; LENS POWER CALCULATION; KERATOMETRY; REPRODUCIBILITY; DEVICE; PRECISION;
D O I
10.1016/j.jcrs.2015.07.039
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To estimate the repeatability of biometric parameters obtained with a new swept-source biometer and to compare the agreement with that of partial coherence interferometry (PCI) and optical low-coherence reflectometry (OLCR). SETTING: Department of Ophthalmology, Helios Hospital Erfurt, Erfurt, Julius-Maximilians University, Wurzburg, and Philipps University, Marburg, Germany. DESIGN: Prospective comparative multicenter clinical study. METHODS: Biometry was taken with the use of 3 different biometers: the IOLMaster 700 swept source biometer, the PCI-based IOLMaster 500, and the OCLR-based Lenstar LS 900. Axial length (AL), anterior chamber depth (ACD), and spherical equivalent (SE) were compared between swept source and PCI biometry and central corneal thickness (CCT) and lens thickness (LT) between swept-source and OLCR biometry. The repeatability of swept-source biometry was evaluated on the basis of 3 measurements captured for each patient. RESULTS: One hundred twenty cataract eyes were included in the study. The mean difference between swept-source and PCI biometry for AL, ACD, and SE measurements was 4 mu m +/- 25 (SD), 17 +/- 122 mu m, and -0.001 +/- 0.19 diopter (D), respectively. The mean difference between swept-source and OLCR biometry for LT and CCT measurements was 21 +/- 122 mu m and 0.15 +/- 4.51 mu m, respectively. Differences between swept-source biometry and the other devices distributed around zero without statistical significance. The standard deviation of repeatability for AL, ACD, LT, CCT, and SE was 8.8 mu m, 9.8 mu m, 2.3 mu m, 19.5 mu m, and 0.1 D, respectively. CONCLUSIONS: Swept-source biometry showed high repeatability performance for all biometric parameters. The agreement of AL, ACD, and SE between swept-source and PCI biometry as well as that of LT and CCT between swept-source and OLCR biometry was excellent. It remains to be validated whether high repeatability shown by swept-source biometry will result in better postoperative refractive outcomes.
引用
收藏
页码:76 / 83
页数:8
相关论文
共 50 条
  • [21] Meta-analysis of optical low-coherence reflectometry versus partial coherence interferometry biometry
    Jinhai Huang
    Colm McAlinden
    Yingying Huang
    Daizong Wen
    Giacomo Savini
    Ruixue Tu
    Qinmei Wang
    Scientific Reports, 7
  • [22] Swept-Source Optical Coherence Tomography-Based Biometry: A Comprehensive Overview
    Borgia, Alfredo
    Raimondi, Raffaele
    Sorrentino, Tania
    Santoru, Francesco
    Buzzi, Matilde
    Borgia, Vittorio
    Scorcia, Vincenzo
    Giannaccare, Giuseppe
    PHOTONICS, 2022, 9 (12)
  • [23] Agreement between a new fully automatic ocular biometer based on optical low-coherence reflectometry and an optical biometer based on Scheimpflug imaging combined with partial coherence interferometry
    Ning, Rui
    Xu, Huilin
    Li, Zheng
    Yu, Jinjin
    Xu, Shuoyu
    Lei, Chak Seng
    Wang, Yiran
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Huang, Jinhai
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [24] Comparison of a New Optical Biometer That Combines Scheimpflug Imaging With Partial Coherence Interferometry With That of an Optical Biometer Based on Swept-Source Optical Coherence Tomography and Placido-Disk Topography
    Chen, Shihao
    Zhang, Qiaoyue
    Savini, Giacomo
    Zhang, Shuangzhe
    Huang, Xiaomin
    Yu, Jinjin
    Wang, Yirang
    Ning, Rui
    Huang, Jinhai
    Tu, Ruixue
    FRONTIERS IN MEDICINE, 2022, 8
  • [25] Comparison of two novel swept-source optical coherence tomography devices to a partial coherence interferometry-based biometer
    Chan, Tommy C. Y.
    Yu, Marco C. Y.
    Chiu, Vivian
    Lai, Gilda
    Leung, Christopher K. S.
    Chan, Poemen P. M.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [26] Comparison of two novel swept-source optical coherence tomography devices to a partial coherence interferometry-based biometer
    Tommy C. Y. Chan
    Marco C. Y. Yu
    Vivian Chiu
    Gilda Lai
    Christopher K. S. Leung
    Poemen P. M. Chan
    Scientific Reports, 11
  • [27] Repeatability and interobserver reproducibility of a new optical biometer based on swept-source optical coherence tomography and comparison with IOLMaster
    Huang, Jinhai
    Savini, Giacomo
    Hoffer, Kenneth J.
    Chen, Hao
    Lu, Weicong
    Hu, Qingjie
    Bao, Fangjun
    Wang, Qinmei
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (04) : 493 - 498
  • [28] Comparison of 2 swept-source optical coherence tomography-based biometry devices
    Fisus, Andreea D.
    Hirnschall, Nino D.
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (01): : 87 - 92
  • [29] Axial Length Measurement Failure Rates With Biometers Using Swept-Source Optical Coherence Tomography Compared to Partial-Coherence Interferometry and Optical Low-Coherence Interferometry
    Mcalinden, Colm
    Wang, Qinmei
    Gao, Rongrong
    Zhao, Weiqi
    Yu, Ayong
    Li, Yu
    Guo, Yan
    Huang, Jinhai
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 173 : 64 - 69
  • [30] Ocular biometry with swept-source optical coherence tomography
    Montes-Mico, Robert
    Pastor-Pascual, Francisco
    Ruiz-Mesa, Ramon
    Tana-Rivero, Pedro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (06): : 802 - 814