Comparison of 2 swept-source optical coherence tomography-based biometry devices

被引:38
|
作者
Fisus, Andreea D. [1 ]
Hirnschall, Nino D. [1 ]
Findl, Oliver [1 ]
机构
[1] Hanusch Hosp, Vienna Inst Res Ocular Surg, Karl Landsteiner Inst, Dept Ophthalmol, Vienna, Austria
来源
关键词
AGREEMENT; INTERFEROMETRY; REPEATABILITY;
D O I
10.1097/j.jcrs.0000000000000373
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare 2 swept-source optical coherence tomography (SS-OCT) biometers, IOLMaster 700 (biometer A), and ANTERION (biometer B). Setting: Department of Ophthalmology, Vienna Institute for Research in Ocular Surgery, Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria. Design: Retrospective study. Method: Biometric measurements of cataract patients performed between June and July 2019 were reviewed. Patients scheduled for cataract surgery were measured with both SS-OCT devices on the same day. The following biometry parameters were compared: keratometry, central corneal thickness, anterior chamber depth (ACD), lens thickness (LT), and axial length (AL). Result: In total, 389 eyes of 209 subjects were measured with both devices. The mean absolute difference between the keratometry data of the 2 devices was 0.04 +/- 0.05 mm (7.80 +/- 026 mm for biometer A and 7.82 +/- 0.26 mm for biometer B; P < .0001) for the steep keratometry readings and 0.04 +/- 0.04 mm (7.63 +/- 0.26 mm and 7.65 +/- 0.25 mm; P< .0001) for the fiat keratometry readings. For ACD and LT, the mean absolute difference was 0.07 +/- 0.04 mm and 0.07 +/- 0.04 mm. The mean absolute difference for AL was 0.02 +/- 0.03 mm (23.55 +/- 1.18 mm for biometer A and 23.54 +/- 1.18 mm for biometer B; P < .0001). Conclusions: Good agreement was found between the 2 devices, with a minor offset for ACD and LT measurements. Although differences were found to be small, the devices should not be used interchangeably. Copyright (C) 2020 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:87 / 92
页数:6
相关论文
共 50 条
  • [1] Swept-Source Optical Coherence Tomography-Based Biometry: A Comprehensive Overview
    Borgia, Alfredo
    Raimondi, Raffaele
    Sorrentino, Tania
    Santoru, Francesco
    Buzzi, Matilde
    Borgia, Vittorio
    Scorcia, Vincenzo
    Giannaccare, Giuseppe
    [J]. PHOTONICS, 2022, 9 (12)
  • [2] The effect of cycloplegia on biometric measurements using swept-source optical coherence tomography-based biometry
    Ozcaliskan, Sehnaz
    Yenerel, Nursal Melda
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2019, 102 (05) : 501 - 505
  • [3] Ocular biometry with swept-source optical coherence tomography
    Montes-Mico, Robert
    Pastor-Pascual, Francisco
    Ruiz-Mesa, Ramon
    Tana-Rivero, Pedro
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (06): : 802 - 814
  • [4] Comparison of ocular biometry in Chinese patients using two swept-source optical coherence tomography devices
    Ho, Vivian Wing -Man
    Nguyen, Hong Chau
    Wong, Siu-Hong
    Li, Anita Lai-Wah
    Li, Kenneth Kai Wang
    [J]. ANNALS OF EYE SCIENCE, 2023, 8
  • [5] Comparison of Intraocular Lens Power Prediction Accuracy Between 2 Swept-Source Optical Coherence Tomography Biometry Devices
    Sorkin, Nir
    Zadok, Rotem
    Savini, Giacomo
    Kan-Tor, Yoav
    Benjamini, Yuval
    Levinger, Eliya
    Bardugo, Judith
    Abulafia, Adi
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 265 : 156 - 164
  • [6] Clinical comparison of a new swept-source optical coherence tomography-based optical biometer and a time-domain optical coherence tomography-based optical biometer
    Srivannaboon, Sabong
    Chirapapaisan, Chareenun
    Chonpimai, Pratuangsri
    Loket, Siriwan
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (10): : 2224 - 2232
  • [7] Macular disease detection with a swept-source optical coherence tomography-based biometry device in patients scheduled for cataract surgery
    Hirnschall, Nino
    Leisser, Christoph
    Radda, Stephan
    Maedel, Sophie
    Findl, Oliver
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (04): : 530 - 536
  • [8] Repeatability and agreement in optical biometry of a new swept-source optical coherence tomography-based biometer versus partial coherence interferometry and optical low-coherence reflectometry
    Kunert, Kathleen S.
    Peter, Monika
    Blum, Marcus
    Haigis, Wolfgang
    Sekundo, Walter
    Schuetze, Juliane
    Bueehren, Tobias
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01): : 76 - 83
  • [9] Comparison of Optical Low-Coherence Reflectometry and Swept-Source OCT-Based Biometry Devices in Dense Cataracts
    Vasavada, Shail A.
    Patel, Priyanka
    Vaishnav, Vineet R.
    Ashena, Zahra
    Srivastava, Samaresh
    Vasavada, Vaishali
    Nanavaty, Mayank A.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (08) : 557 - 564
  • [10] Ocular biometry and refractive outcomes using two swept-source optical coherence tomography-based biometers with segmental or equivalent refractive indices
    Miki Kamikawatoko Omoto
    Hidemasa Torii
    Sachiko Masui
    Masahiko Ayaki
    Kazuo Tsubota
    Kazuno Negishi
    [J]. Scientific Reports, 9