Comparison of 2 swept-source optical coherence tomography-based biometry devices

被引:38
|
作者
Fisus, Andreea D. [1 ]
Hirnschall, Nino D. [1 ]
Findl, Oliver [1 ]
机构
[1] Hanusch Hosp, Vienna Inst Res Ocular Surg, Karl Landsteiner Inst, Dept Ophthalmol, Vienna, Austria
来源
关键词
AGREEMENT; INTERFEROMETRY; REPEATABILITY;
D O I
10.1097/j.jcrs.0000000000000373
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare 2 swept-source optical coherence tomography (SS-OCT) biometers, IOLMaster 700 (biometer A), and ANTERION (biometer B). Setting: Department of Ophthalmology, Vienna Institute for Research in Ocular Surgery, Karl Landsteiner Institute, Hanusch Hospital, Vienna, Austria. Design: Retrospective study. Method: Biometric measurements of cataract patients performed between June and July 2019 were reviewed. Patients scheduled for cataract surgery were measured with both SS-OCT devices on the same day. The following biometry parameters were compared: keratometry, central corneal thickness, anterior chamber depth (ACD), lens thickness (LT), and axial length (AL). Result: In total, 389 eyes of 209 subjects were measured with both devices. The mean absolute difference between the keratometry data of the 2 devices was 0.04 +/- 0.05 mm (7.80 +/- 026 mm for biometer A and 7.82 +/- 0.26 mm for biometer B; P < .0001) for the steep keratometry readings and 0.04 +/- 0.04 mm (7.63 +/- 0.26 mm and 7.65 +/- 0.25 mm; P< .0001) for the fiat keratometry readings. For ACD and LT, the mean absolute difference was 0.07 +/- 0.04 mm and 0.07 +/- 0.04 mm. The mean absolute difference for AL was 0.02 +/- 0.03 mm (23.55 +/- 1.18 mm for biometer A and 23.54 +/- 1.18 mm for biometer B; P < .0001). Conclusions: Good agreement was found between the 2 devices, with a minor offset for ACD and LT measurements. Although differences were found to be small, the devices should not be used interchangeably. Copyright (C) 2020 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:87 / 92
页数:6
相关论文
共 50 条
  • [41] Swept-source optical coherence tomography and swept-source optical coherence tomography angiography findings in circumscribed choroidal hemangioma before and after transpupillary thermotherapy
    Mirzayev, Ibadulla
    Gunduz, Ahmet Kaan
    Ergin, Ahmet
    [J]. LASERS IN MEDICAL SCIENCE, 2024, 39 (01)
  • [42] Comparison of ocular biometric measurements in patients with cataract using three swept-source optical coherence tomography devices
    Richul Oh
    Joo Youn Oh
    Hyuk Jin Choi
    Mee Kum Kim
    Chang Ho Yoon
    [J]. BMC Ophthalmology, 21
  • [43] Comparison of ocular biometric measurements in patients with cataract using three swept-source optical coherence tomography devices
    Oh, Richul
    Oh, Joo Youn
    Choi, Hyuk Jin
    Kim, Mee Kum
    Yoon, Chang Ho
    [J]. BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [44] Comparison of Retinal Thicknesses Measured Using Swept-Source and Spectral-Domain Optical Coherence Tomography Devices
    Tan, Colin S.
    Chan, Joel C.
    Cheong, Kai Xiong
    Ngo, Wei Kiong
    Sadda, SriniVas R.
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2015, 46 (02): : 172 - 179
  • [45] Impact of lens opacity and axial length on concomitant screening of maculopathy by swept-source optical coherence tomography-based optical biometer
    Qin, Yingyan
    Ye, Shaobi
    Liu, Liangping
    Wu, Mingxing
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2022, 10 (15)
  • [46] Evaluation of Choroidal Nevi with Swept-Source Optical Coherence Tomography
    Ung, Cindy
    Lains, Ines
    Woods, Russell L.
    Lane, Anne Marie
    Husain, Deeba
    Miller, Joan W.
    Gragoudas, Evangelos S.
    Kim, Ivana K.
    Miller, John B.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [47] Swept-source optical coherence tomography angiography in serpiginous choroiditis
    Montorio, Daniela
    Giuffre, Chiara
    Miserocchi, Elisabetta
    Modorati, Giulio
    Sacconi, Riccardo
    Mercuri, Stefano
    Querques, Lea
    Querques, Giuseppe
    Bandello, Francesco
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (07) : 991 - 995
  • [48] SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IMAGING OF THE CHORIOCAPILLARIS
    Ledesma-Gil, Gerardo
    Fernandez-Avellaneda, Pedro
    Spaide, Richard F.
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2021, 41 (07): : 1373 - 1378
  • [49] Cataract quantification using swept-source optical coherence tomography
    Bras, Joao E. G.
    Sickenberger, Wolfgang
    Hirnschall, Nino
    Findl, Oliver
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (12): : 1478 - 1481
  • [50] Image artefacts in swept-source optical coherence tomography angiography
    Falavarjani, Khalil Ghasemi
    Al-Sheikh, Mayss
    Akil, Handan
    Sadda, Srinivas R.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (05) : 564 - 568