Comparison of ocular biometric measurements in patients with cataract using three swept-source optical coherence tomography devices

被引:43
|
作者
Oh, Richul [1 ]
Oh, Joo Youn [1 ,2 ,3 ]
Choi, Hyuk Jin [1 ,2 ,3 ,4 ]
Kim, Mee Kum [1 ,2 ,3 ]
Yoon, Chang Ho [1 ,2 ,3 ]
机构
[1] Seoul Natl Univ Hosp, Dept Ophthalmol, 101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ, Dept Ophthalmol, Coll Med, Seoul, South Korea
[3] Seoul Natl Univ Hosp, Artificial Eye Ctr, Lab Ocular Regenerat Med & Immunol LORMI, Biomed Res Inst, Seoul, South Korea
[4] Seoul Natl Univ Hosp, Dept Ophthalmol, Healthcare Syst Gangnam Ctr, Seoul, South Korea
关键词
Ocular biometry; Cataract; Total keratometry; Swept-source optical coherence tomography devices; ANTERION; CASIA2; IOLMaster; 700;
D O I
10.1186/s12886-021-01826-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Precise measurement of ocular biometry is critical for determining intraocular lens power. Newly developed swept-source optical coherence tomography (SS-OCT) - based ocular biometric devices, ANTERION and CASIA2 provide ocular biometric measurements as IOLMaster 700. This study aimed to assess agreement between three devices. Methods: This retrospective comparative study includes patients with cataract who underwent ocular biometric measurements with three devices, ANTERION, CASIA2, and IOLMaster 700, at Seoul National University Hospital, in April 2020. Anterior keratometry, total keratometry, central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), and axial length (AL) were the main parameters for the comparison. To assess the agreement between the devices, intraclass coefficient (ICC) and Bland-Altman analysis with 95% limits of agreement (LoA) were used. Results: A total of 47 eyes of 29 patients were measured with three devices. Average anterior keratometry showed excellent agreement (ICC >= 0.989), and the mean difference was less than 0.1 D. However, the ICC of the total average keratometry ranged from 0.808 to 0.952, and the difference was more than 0.43 D. The AL measured by ANTERION and IOLMaster 700 showed excellent agreement (ICC = 0.999), and the mean difference was 0.005 mm. The ANTERION and IOLMaster 700 did not obtain AL in six (12.8%) and three (6.4%) cases, respectively (P = 0.001 by Fisher's exact test). The CCT, ACD, and LT also showed excellent agreement (ICC > 0.9). Conclusions: The new SS-OCT-based devices, ANTERION, and CASIA2 showed a good agreement with IOLMaster 700 in measuring ocular biometry except for the total keratometry. The AL of ANTERION and IOLMaster 700 showed excellent agreement.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Comparison of ocular biometric measurements in patients with cataract using three swept-source optical coherence tomography devices
    Richul Oh
    Joo Youn Oh
    Hyuk Jin Choi
    Mee Kum Kim
    Chang Ho Yoon
    [J]. BMC Ophthalmology, 21
  • [2] Comparison of ocular biometric parameters between two swept-source optical coherence tomography devices and Scheimpflug tomography in patients with cataract
    Ma, Shan
    Li, Cheng
    Sun, Jing
    Yang, Jun
    Wen, Kai
    Chen, Xi-Teng
    Zhao, Fang-Yu
    Gao, Rong-Yu
    Tian, Fang
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2024, 17 (08) : 1437 - 1446
  • [3] Comparison of Anterior Ocular Biometric Measurements Using Swept-Source and Time-Domain Optical Coherence Tomography
    Chen, Sisi
    Gao, Rongrong
    McAlinden, Colm
    Ye, Junming
    Wang, Yiran
    Chen, Min
    Huang, Jinhai
    Sun, Yong
    Yu, A-Yong
    [J]. JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [4] Comparison of ocular biometry in Chinese patients using two swept-source optical coherence tomography devices
    Ho, Vivian Wing -Man
    Nguyen, Hong Chau
    Wong, Siu-Hong
    Li, Anita Lai-Wah
    Li, Kenneth Kai Wang
    [J]. ANNALS OF EYE SCIENCE, 2023, 8
  • [5] Comparison of ocular biometric measurements between a new swept-source optical coherence tomography and a common optical low coherence reflectometry
    Rongrong Gao
    Hao Chen
    Giacomo Savini
    Yaxin Miao
    Xiaorui Wang
    Jing Yang
    Weiqi Zhao
    Qinmei Wang
    Jinhai Huang
    [J]. Scientific Reports, 7
  • [6] Comparison of ocular biometric measurements between a new swept-source optical coherence tomography and a common optical low coherence reflectometry
    Gao, Rongrong
    Chen, Hao
    Savini, Giacomo
    Miao, Yaxin
    Wang, Xiaorui
    Yang, Jing
    Zhao, Weiqi
    Wang, Qinmei
    Huang, Jinhai
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [7] Effect of contact lenses on ocular biometric measurements based on swept-source optical coherence tomography
    Ferrer-Blasco, Teresa
    Esteve-Taboada, Jose J.
    Dominguez-Vicent, Alberto
    Aloy, Miguel A.
    Adsuara, Jose E.
    Mimica, Petar
    Montes-Mico, Robert
    [J]. ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2019, 82 (02) : 129 - 135
  • [8] Cataract quantification using swept-source optical coherence tomography
    Bras, Joao E. G.
    Sickenberger, Wolfgang
    Hirnschall, Nino
    Findl, Oliver
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (12): : 1478 - 1481
  • [9] Cataract quantification using swept-source optical coherence tomography
    Panthier, Christophe
    Saad, Main
    Rouger, Helene
    Gatinel, Damien
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06): : 893 - 894
  • [10] Ocular biometric changes with different accommodative stimuli using swept-source optical coherence tomography
    Ferrer-Blasco, Teresa
    Esteve-Taboada, Jose J.
    Monsalvez-Romin, Daniel
    Aloy, Miguel A.
    Adsuara, Jose E.
    Cerda-Duran, Pablo
    Montes-Mico, Robert
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (02) : 303 - 310