Comparison of ocular biometric measurements in patients with cataract using three swept-source optical coherence tomography devices

被引:42
|
作者
Oh, Richul [1 ]
Oh, Joo Youn [1 ,2 ,3 ]
Choi, Hyuk Jin [1 ,2 ,3 ,4 ]
Kim, Mee Kum [1 ,2 ,3 ]
Yoon, Chang Ho [1 ,2 ,3 ]
机构
[1] Seoul Natl Univ Hosp, Dept Ophthalmol, 101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ, Dept Ophthalmol, Coll Med, Seoul, South Korea
[3] Seoul Natl Univ Hosp, Artificial Eye Ctr, Lab Ocular Regenerat Med & Immunol LORMI, Biomed Res Inst, Seoul, South Korea
[4] Seoul Natl Univ Hosp, Dept Ophthalmol, Healthcare Syst Gangnam Ctr, Seoul, South Korea
关键词
Ocular biometry; Cataract; Total keratometry; Swept-source optical coherence tomography devices; ANTERION; CASIA2; IOLMaster; 700;
D O I
10.1186/s12886-021-01826-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Precise measurement of ocular biometry is critical for determining intraocular lens power. Newly developed swept-source optical coherence tomography (SS-OCT) - based ocular biometric devices, ANTERION and CASIA2 provide ocular biometric measurements as IOLMaster 700. This study aimed to assess agreement between three devices. Methods: This retrospective comparative study includes patients with cataract who underwent ocular biometric measurements with three devices, ANTERION, CASIA2, and IOLMaster 700, at Seoul National University Hospital, in April 2020. Anterior keratometry, total keratometry, central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT), and axial length (AL) were the main parameters for the comparison. To assess the agreement between the devices, intraclass coefficient (ICC) and Bland-Altman analysis with 95% limits of agreement (LoA) were used. Results: A total of 47 eyes of 29 patients were measured with three devices. Average anterior keratometry showed excellent agreement (ICC >= 0.989), and the mean difference was less than 0.1 D. However, the ICC of the total average keratometry ranged from 0.808 to 0.952, and the difference was more than 0.43 D. The AL measured by ANTERION and IOLMaster 700 showed excellent agreement (ICC = 0.999), and the mean difference was 0.005 mm. The ANTERION and IOLMaster 700 did not obtain AL in six (12.8%) and three (6.4%) cases, respectively (P = 0.001 by Fisher's exact test). The CCT, ACD, and LT also showed excellent agreement (ICC > 0.9). Conclusions: The new SS-OCT-based devices, ANTERION, and CASIA2 showed a good agreement with IOLMaster 700 in measuring ocular biometry except for the total keratometry. The AL of ANTERION and IOLMaster 700 showed excellent agreement.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Cataract significantly influences quantitative measurements on swept-source optical coherence tomography angiography imaging
    Yu, Siqing
    Frueh, Beatrice E.
    Steinmair, Dagmar
    Ebneter, Andreas
    Wolf, Sebastian
    Zinkernagel, Martin S.
    Munk, Marion R.
    PLOS ONE, 2018, 13 (10):
  • [22] Comparison of 2 swept-source optical coherence tomography-based biometry devices
    Fisus, Andreea D.
    Hirnschall, Nino D.
    Findl, Oliver
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (01): : 87 - 92
  • [23] Three-Dimensional Cataract Crystalline Lens Imaging With Swept-Source Optical Coherence Tomography
    de Castro, Alberto
    Benito, Antonio
    Manzanera, Silvestre
    Mompean, Juan
    Canizares, Belen
    Martinez, David
    Maria Marin, Jose
    Grulkowski, Ireneusz
    Artal, Pablo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (02) : 897 - 903
  • [24] Agreement between a new swept-source ocular coherence tomography and a Placido disc-dual Scheimpflug ocular biometric devices
    McLintock, Cameron
    Niyazmand, Hamed
    Seo, Shiney
    Barrett, Graham
    Kumar Nilagiri, Vinay
    Karimian, Sahar
    McKelvie, James
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (02) : 905 - 911
  • [25] Normal and Cataract Crystalline Lens Evaluation with Swept-Source Optical Coherence Tomography
    De Castro, Alberto
    Benito, Antonio
    Manzanera, Silvestre
    Mompean, Juan
    Canizares, Belen
    Maria Marin, Jose
    Grulkowski, Ireneusz
    Artal, Pablo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [26] "Diamond wire mesh" appearance of cataract on swept-source optical coherence tomography
    Delhiwala, K.
    Shah, K.
    Khamar, B.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2023, 46 (08): : 992 - 993
  • [27] Efficacy of Swept-source Optical Coherence Tomography in Axial Length Measurement for Advanced Cataract Patients
    Chirapapaisan, Chareenun
    Srivannaboon, Sabong
    Chonpimai, Pratuangsri
    OPTOMETRY AND VISION SCIENCE, 2020, 97 (03) : 186 - 191
  • [28] Comparison of Anterior Segment Measurements Between Swept-source Optical Coherence Tomography and Schiempflug Coherence Interferometer
    Song, Jiyun
    Na, Kyung Sun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (12): : 1158 - 1167
  • [29] Ocular biometric repeatability using a new high-resolution swept-source optical coherence tomographer
    Ruiz-Mesa, Ramon
    Aguilar-Corcoles, Salvador
    Montes-Mico, Robert
    Tana-Rivero, Pedro
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (06) : 591 - 597
  • [30] Factors influencing choroidal thickness measurements using swept-source optical coherence tomography
    Caramoy, Albert
    Kirchhof, Bernd
    Cursiefen, Claus
    Heindl, Ludwig M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)