Comparison of Retinal Thicknesses Measured Using Swept-Source and Spectral-Domain Optical Coherence Tomography Devices

被引:36
|
作者
Tan, Colin S. [1 ,2 ]
Chan, Joel C. [1 ]
Cheong, Kai Xiong [1 ]
Ngo, Wei Kiong [1 ]
Sadda, SriniVas R. [3 ]
机构
[1] Tan Tock Seng Hosp, Natl Healthcare Grp Eye Inst, Singapore 308433, Singapore
[2] Natl Healthcare Grp Eye Inst, Fundus Image Reading Ctr, Singapore, Singapore
[3] Univ Calif Los Angeles, Doheny Eye Inst, Los Angeles, CA USA
来源
关键词
DIABETIC MACULAR EDEMA; CHOROIDAL THICKNESS; TIME-DOMAIN; NORMAL EYES; SOURCE OCT; TRAP-EYE; INSTRUMENTS; REPRODUCIBILITY; ASSOCIATION; CIRRUS;
D O I
10.3928/23258160-20150213-23
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To compare retinal thicknesses measured using swept-source optical coherence tomography (SS-OCT) and spectraldomain (SD) OCT devices. PATIENTS AND METHODS: In a cohort study of 76 healthy eyes and 21 eyes with high myopia, mean retinal thicknesses in ETDRS subfields were compared between OCT scans obtained from the Topcon DRI OCT-1 (Topcon, Tokyo, Japan), Spectralis OCT (Heidelberg Engineering, Heidelberg, Germany), and Cirrus HD-OCT (Carl Zeiss Meditec, Dublin, CA). RESULTS: Central retinal thickness measurements differed significantly among the three OCT devices (Spectralis: 271 mu m; Cirrus: 254 mu m; DRI OCT-1: 238 mu m; P < .001), with mean differences ranging from 15.6 mu m to 37 mu m. Intraclass correlation coefficients were at least 0.94 for any pair of machines. Similar results were observed in all nine ETDRS subfields. In all sectors, retinal thickness measurements obtained using the 3-D and radial scans of the SS-OCT were similar (mean differences: 0.7 to 3.8 mu m). CONCLUSION: Retinal thickness measurements obtained from DRI OCT-1 and SD-OCT are different and should be accounted for when comparing results of OCT scans from different devices.
引用
收藏
页码:172 / 179
页数:8
相关论文
共 50 条
  • [1] Comparison of repeatability of swept-source and spectral-domain optical coherence tomography for measuring inner retinal thickness in retinal disease
    Hong, Eun Hee
    Ryu, So Jung
    Kang, Min Ho
    Seong, Mincheol
    Cho, Heeyoon
    Yeom, Jong Hun
    Shin, Yong Un
    [J]. PLOS ONE, 2019, 14 (01):
  • [2] Comparison of the Lamina Cribrosa Measurements Obtained by Spectral-Domain and Swept-Source Optical Coherence Tomography
    Cakmak, Semih
    Altan, Cigdem
    Topcu, Husna
    Arici, Murat
    Pasaoglu, Isil
    Basarir, Berna
    Solmaz, Banu
    [J]. CURRENT EYE RESEARCH, 2019, 44 (09) : 968 - 974
  • [3] Diagnostic Ability of Swept-Source and Spectral-Domain Optical Coherence Tomography for Glaucoma
    Lee, Sang Yeop
    Bae, Hyoung Won
    Seong, Gong Je
    Kim, Chan Yun
    [J]. YONSEI MEDICAL JOURNAL, 2018, 59 (07) : 887 - 896
  • [4] Visualization of the Macula in Gas-filled Eyes using Swept-Source Optical Coherence Tomography: Comparison with Spectral-Domain Optical Coherence Tomography
    Lee, Byung Ro
    Ahn, Seong Joon
    Park, Seung Hoon
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [5] Comparison of macular retinal and choroidal thicknesses from Swept Source and Spectral Domain Optical Coherence Tomography
    Cheong, Kai Xiong
    Lim, Louis Wei Yi
    Ngo, Wei Kiong
    Tan, Colin S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [6] Agreement Between Spectral-Domain and Swept-Source Optical Coherence Tomography Retinal Thickness Measurements in Macular and Retinal Disease
    Hanumunthadu, Daren
    Keane, Pearse A.
    Balaskas, Konstantinos
    Dubis, Adam M.
    Kalitzeos, Angelos
    Michaelides, Michel
    Patel, Praveen J.
    [J]. OPHTHALMOLOGY AND THERAPY, 2021, 10 (04) : 913 - 922
  • [7] Agreement Between Spectral-Domain and Swept-Source Optical Coherence Tomography Retinal Thickness Measurements in Macular and Retinal Disease
    Daren Hanumunthadu
    Pearse A. Keane
    Konstantinos Balaskas
    Adam M. Dubis
    Angelos Kalitzeos
    Michel Michaelides
    Praveen J. Patel
    [J]. Ophthalmology and Therapy, 2021, 10 : 913 - 922
  • [8] Comparison of Spectral-Domain and Swept-Source Optical Coherence Tomography Choroidal Thickness Measurements in Normal Eyes
    Luu, Jennifer Yen
    Sha, Patricia
    Durbin, Mary K.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [9] Comparison of swept-source versus spectral-domain optical coherence tomography angiography for detection of macular neovascularization
    Lentzsch, Anna
    Schoellhorn, Laura
    Schnorr, Christel
    Siggel, Robert
    Liakopoulos, Sandra
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (01) : 113 - 119
  • [10] Comparison of swept-source versus spectral-domain optical coherence tomography angiography for detection of macular neovascularization
    Anna Lentzsch
    Laura Schöllhorn
    Christel Schnorr
    Robert Siggel
    Sandra Liakopoulos
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2022, 260 : 113 - 119