Advances in swept-source optical coherence tomography and optical coherence tomography angiography

被引:21
|
作者
Zheng, Fang [1 ]
Deng, Xiaofeng [2 ]
Zhang, Qi [1 ]
He, Jingliang [1 ]
Ye, Panpan [1 ]
Liu, Shan [3 ]
Li, Peng [2 ]
Zhou, Jian [4 ]
Fang, Xiaoyun [1 ]
机构
[1] Zhejiang Univ, Sch Med, Affiliated Hosp 2, Eye Ctr, 01 Xihu Blvd, Hangzhou 310009, Peoples R China
[2] Zhejiang Univ, Coll Opt Sci & Engn, State Key Lab Modern Opt Instrumentat, Hangzhou, Peoples R China
[3] Shanghai Jiao Tong Univ, Sch Med, Shanghai Gen Hosp, Dept Ophthalmol, Shanghai, Peoples R China
[4] TowardPi Beijing Med Technol Ltd, Shanghai, Peoples R China
来源
关键词
Swept-source optical coherence tomography; angiography; Anterior segment; Vitreous; Posterior segment; SOURCE OCT ANGIOGRAPHY; PERSISTENT HYPERTRANSMISSION DEFECTS; POLYPOIDAL CHOROIDAL VASCULOPATHY; CHORIOCAPILLARIS FLOW DEFICITS; MACULAR TELANGIECTASIA TYPE-2; FOURIER DOMAIN OCT; ANGLE-CLOSURE; SPECTRAL-DOMAIN; ULTRAHIGH-SPEED; DIABETIC-RETINOPATHY;
D O I
10.1016/j.aopr.2022.10.005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The fast development of swept-source optical coherence tomography (SS-OCT) and swept-source optical coherence tomography angiography (SS-OCTA) enables both anterior and posterior imaging of the eye. These techniques have evolved from a research tool to an essential clinical imaging modality. Main text: The longer wavelength and faster speed of SS-OCT and SS-OCTA facilitate better visualization of structure and vasculature below pigmented tissue with a larger field of view of the posterior segment and 360degree visualization of the anterior segment. In the past 10 years, algorithms dealing with OCT and OCTA data also vastly improved the image quality and enabled the automated quantification of OCT- and OCTA-derived metrics. This technology has enriched our current understanding of healthy and diseased eyes. Even though the high cost of the systems currently limited the widespread use of SS-OCT and SS-OCTA at the first beginning, the gap between research and clinic practice got obviously shortened in the past few years. Conclusions: SS-OCT and SS-OCTA will continue to evolve rapidly, contributing to a paradigm shift toward more widespread adoption of new imaging technology in clinical practice.
引用
收藏
页码:67 / 79
页数:13
相关论文
共 50 条
  • [1] Widefield Swept-Source Optical Coherence Tomography Angiography
    Shahidzadeh, Anoush
    Kim, Alice Yon
    Aziz, Hassan A.
    Durbin, Mary K.
    Puliafito, Carmen A.
    Kashani, Amir H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [2] Swept-source optical coherence tomography angiography in serpiginous choroiditis
    Montorio, Daniela
    Giuffre, Chiara
    Miserocchi, Elisabetta
    Modorati, Giulio
    Sacconi, Riccardo
    Mercuri, Stefano
    Querques, Lea
    Querques, Giuseppe
    Bandello, Francesco
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (07) : 991 - 995
  • [3] SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY IMAGING OF THE CHORIOCAPILLARIS
    Ledesma-Gil, Gerardo
    Fernandez-Avellaneda, Pedro
    Spaide, Richard F.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2021, 41 (07): : 1373 - 1378
  • [4] Image artefacts in swept-source optical coherence tomography angiography
    Falavarjani, Khalil Ghasemi
    Al-Sheikh, Mayss
    Akil, Handan
    Sadda, Srinivas R.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (05) : 564 - 568
  • [5] Swept-source optical coherence tomography angiography in toxoplasmic retinochoroiditis
    Doukh, Meryem
    Ksiaa, Imen
    Ben Amor, Hager
    Abroug, Nesrine
    Jelliti, Bechir
    Khochteli, Sana
    Khairallah, Moncef
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [6] The Latest Updates in Swept-Source Optical Coherence Tomography Angiography
    Xia, Fan
    Hua, Rui
    DIAGNOSTICS, 2024, 14 (01)
  • [7] Clinical Observation of Choroidal Osteoma Using Swept-Source Optical Coherence Tomography and Optical Coherence Tomography Angiography
    Xuan, Yi
    Chang, Qing
    Zhang, Yongjin
    Ye, Xiaofeng
    Liu, Wei
    Li, Lei
    Wang, Keyan
    Zhou, Jian
    Wang, Min
    APPLIED SCIENCES-BASEL, 2022, 12 (09):
  • [8] Swept-source optical coherence tomography and optical coherence tomography angiography in acquired toxoplasmic chorioretinitis: A case report
    Vezzola D.
    Allegrini D.
    Borgia A.
    Fogagnolo P.
    Rossetti L.M.
    Romano M.R.
    De Cillà S.
    Journal of Medical Case Reports, 12 (1)
  • [9] Swept-source optical coherence tomography and swept-source optical coherence tomography angiography findings in circumscribed choroidal hemangioma before and after transpupillary thermotherapy
    Mirzayev, Ibadulla
    Gunduz, Ahmet Kaan
    Ergin, Ahmet
    LASERS IN MEDICAL SCIENCE, 2024, 39 (01)
  • [10] Multimodal imaging of hypertensive chorioretinopathy by swept-source optical coherence tomography and optical coherence tomography angiography Case report
    Rotsos, Tryfon
    Andreanos, Konstantinos
    Blounas, Stelios
    Brouzas, Dimitrios
    Ladas, Dimitrios S.
    Ladas, Ioannis D.
    MEDICINE, 2017, 96 (39)