Experimental study on temperature and performance of an open-cathode PEMFC stack under thermal radiation environment

被引:27
|
作者
Zhang, Jikai [1 ,2 ]
Wang, Changjian [1 ,3 ]
Zhang, Aifeng [1 ,2 ]
机构
[1] Hefei Univ Technol, Sch Civil Engn, Hefei 230009, Anhui, Peoples R China
[2] Anhui Int Joint Res Ctr Hydrogen Safety, Hefei 230009, Peoples R China
[3] Minist Educ, Engn Res Ctr Safety Crit Ind Measurement & Contro, Hefei, Peoples R China
关键词
Open-cathode PEMFC; Thermal radiation; Performance degradation; Temperature distribution; Single -cell voltage uniformity; MEMBRANE FUEL-CELL; IN-SITU MEASUREMENT; RELATIVE-HUMIDITY; BREATHING PEMFC; FLOW CHANNEL; AIR; SYSTEM; OPTIMIZATION; DESIGN; ANODE;
D O I
10.1016/j.apenergy.2022.118646
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The open-cathode proton exchange membrane fuel cell stack is an air-cooled stack, and has the characteristics of small footprint and high power density because of its unique configuration, combining oxidizer and coolant via axial fan. Depending on the demands of the application, proton exchange membrane fuel cells inevitably operate in harsh environments, such as high pressure, low or high temperature, etc. In this study, the performance of a 10-cell open-cathode PEMFC stack under thermal radiation was evaluated. The variations in cathode air temperature and relative humidity, stack temperature, output power and single-cell voltage under three different radiant heat fluxes were obtained by changing the load current and cathode air flow rate. The experimental results show that, even if the thermal radiation is beneficial to improve the stack temperature, the stack performance is not improved in all tested cases. Conversely, the degradation of stack power and failure of the stack continuous operation can be observed, especially for higher radiant heat flux, higher load current and lower air velocity. For the highest radiant heat flux in current study, the temperature of the first single cell closest to the radiant heat source exceeds the maximum allowable operating temperature of 65 degrees C due to the insufficient capacity of air cooling and the heating effect of radiant heat source. The significant drop in the first single-cell voltage results in the rapid degradation of the overall performance of the stack, and finally the stack fails to run continuously.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Performance improvement and numerical study on cathode channel for air-cooled open-cathode proton exchange membrane fuel cells
    Zhang, Lu
    Wu, Xiaoyu
    Deng, Zhijun
    Zhao, Chen
    ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2024, 18 (01)
  • [42] Experimental study on spatiotemporal distribution and variation characteristics of temperature in an open cathode proton exchange membrane fuel cell stack
    Jian, Qifei
    Zhao, Jing
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (49) : 27079 - 27093
  • [43] Optimisation of air cooled, open-cathode fuel cells: Current of lowest resistance and electro-thermal performance mapping
    Meyer, Quentin
    Ronaszegi, Krisztian
    Pei-June, Gan
    Curnick, Oliver
    Ashton, Sean
    Reisch, Tobias
    Adcock, Paul
    Shearing, Paul R.
    Brett, Daniel J. L.
    JOURNAL OF POWER SOURCES, 2015, 291 : 261 - 269
  • [44] Experimental study on cold boot characteristics of PEMFC stack under twice-purge condition
    Sun S.
    Ren C.
    Yang J.
    Ma C.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (05): : 54 - 59
  • [45] Experimental analysis of performance degradation of 3-cell PEMFC stack under dynamic load cycle
    Han, Jaesu
    Han, Jaeyoung
    Yu, Sangseok
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2020, 45 (23) : 13045 - 13054
  • [46] Performance and thermal optimization of different length-width ratio for air-cooled open-cathode fuel cell
    Zhao, Chen
    Xing, Shuang
    Liu, Wei
    Chen, Ming
    Wang, Haijiang
    RENEWABLE ENERGY, 2021, 178 : 1250 - 1260
  • [47] Experimental study on the effect of thermal radiation on the performance and temperature of PEM electrolyzer stacks
    Du, Tao
    Wang, Changjian
    Xu, Yunbo
    Ma, Hongsheng
    Li, Yang
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2025, 197
  • [48] Experimental Study on the Electrochemical Performance of PEMFC under Different Assembly Forces
    Su, Tongze
    Liu, Jiaran
    Wei, Yanqiang
    Li, Yihuizi
    Luo, Weichao
    Tan, Jinzhu
    CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2024, 37 (01)
  • [49] Experimental Study on the Electrochemical Performance of PEMFC under Different Assembly Forces
    Tongze Su
    Jiaran Liu
    Yanqiang Wei
    Yihuizi Li
    Weichao Luo
    Jinzhu Tan
    ChineseJournalofMechanicalEngineering, 2024, 37 (03) : 278 - 287
  • [50] The Hydro-electro-thermal Performance of Air-cooled, Open-cathode Polymer Electrolyte Fuel Cells: Combined Localised Current Density, Temperature and Water Mapping
    Meyer, Quentin
    Ashton, Sean
    Jervis, Rhodri
    Finegan, Donal P.
    Boillat, Pierre
    Cochet, Magali
    Curnick, Oliver
    Reisch, Tobias
    Adcock, Paul
    Shearing, Paul R.
    Brett, Dan J. L.
    ELECTROCHIMICA ACTA, 2015, 180 : 307 - 315