Experimental study on temperature and performance of an open-cathode PEMFC stack under thermal radiation environment

被引:27
|
作者
Zhang, Jikai [1 ,2 ]
Wang, Changjian [1 ,3 ]
Zhang, Aifeng [1 ,2 ]
机构
[1] Hefei Univ Technol, Sch Civil Engn, Hefei 230009, Anhui, Peoples R China
[2] Anhui Int Joint Res Ctr Hydrogen Safety, Hefei 230009, Peoples R China
[3] Minist Educ, Engn Res Ctr Safety Crit Ind Measurement & Contro, Hefei, Peoples R China
关键词
Open-cathode PEMFC; Thermal radiation; Performance degradation; Temperature distribution; Single -cell voltage uniformity; MEMBRANE FUEL-CELL; IN-SITU MEASUREMENT; RELATIVE-HUMIDITY; BREATHING PEMFC; FLOW CHANNEL; AIR; SYSTEM; OPTIMIZATION; DESIGN; ANODE;
D O I
10.1016/j.apenergy.2022.118646
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The open-cathode proton exchange membrane fuel cell stack is an air-cooled stack, and has the characteristics of small footprint and high power density because of its unique configuration, combining oxidizer and coolant via axial fan. Depending on the demands of the application, proton exchange membrane fuel cells inevitably operate in harsh environments, such as high pressure, low or high temperature, etc. In this study, the performance of a 10-cell open-cathode PEMFC stack under thermal radiation was evaluated. The variations in cathode air temperature and relative humidity, stack temperature, output power and single-cell voltage under three different radiant heat fluxes were obtained by changing the load current and cathode air flow rate. The experimental results show that, even if the thermal radiation is beneficial to improve the stack temperature, the stack performance is not improved in all tested cases. Conversely, the degradation of stack power and failure of the stack continuous operation can be observed, especially for higher radiant heat flux, higher load current and lower air velocity. For the highest radiant heat flux in current study, the temperature of the first single cell closest to the radiant heat source exceeds the maximum allowable operating temperature of 65 degrees C due to the insufficient capacity of air cooling and the heating effect of radiant heat source. The significant drop in the first single-cell voltage results in the rapid degradation of the overall performance of the stack, and finally the stack fails to run continuously.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Experimental study of hydrogen purge effects on performance and efficiency of an open-cathode Proton Exchange Membrane fuel cell system
    Strahl, Stephan
    Husar, Attila
    Riera, Jordi
    JOURNAL OF POWER SOURCES, 2014, 248 : 474 - 482
  • [32] Effect of Channel Designs on Open-Cathode PEM Fuel Cell Performance: A Computational Study
    Kreesaeng, Suchart
    Chalermsinsuwan, Benjapon
    Piumsomboon, Pornpote
    2015 INTERNATIONAL CONFERENCE ON ALTERNATIVE ENERGY IN DEVELOPING COUNTRIES AND EMERGING ECONOMIES, 2015, 79 : 733 - 745
  • [33] An experimental and simulation study of novel channel designs for open-cathode high-temperature polymer electrolyte membrane fuel cells
    Thomas, Sobi
    Bates, Alex
    Park, Sam
    Sahu, A. K.
    Lee, Sang C.
    Son, Byung Rak
    Kim, Joo Gon
    Lee, Dong-Ha
    APPLIED ENERGY, 2016, 165 : 765 - 776
  • [34] Experimental study on the dynamic response of voltage and temperature of an open-cathode air-cooled proton exchange membrane fuel cell
    Guo, Ziyang
    Tian, Chenqi
    Gong, Kunying
    Xu, Weiqiang
    Chen, Li
    Tao, Wen-Quan
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 57 : 601 - 615
  • [35] Cell and stack-level study of steady-state and transient behaviour of temperature uniformity of open-cathode proton exchange membrane fuel cells
    Huang, Bi
    Jian, Qifei
    Luo, Lizhong
    Zhao, Jing
    Huang, Zipeng
    Wang, Xiaojun
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (14) : 8148 - 8163
  • [36] Experimental Study of PEMFC Stack Performance Degradation Considering the Shutdown and Rest Processes
    Zhao, Yan
    Luo, Maji
    Yang, Junwei
    Chen, Ben
    Sui, Pang-Chieh
    Zhou, Wei
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2025, 2025 (01)
  • [37] An experimental study for optimizing the energy efficiency of a proton exchange membrane fuel cell with an open-cathode
    Le, Phuong-Long
    Singh, Bhupendra
    Chen, Yong-Song
    Arpornwichanop, Amornchai
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2021, 46 (52) : 26507 - 26517
  • [38] Electrochemical impedance spectroscopy analysis and thermal mapping of different cross-sectional cathode channels in open-cathode polymer electrolyte membrane fuel cell stack
    Thapa, Shikha
    Agarwal, Harshal
    Ganesh, V.
    Sahu, Akhila Kumar
    JOURNAL OF POWER SOURCES, 2024, 613
  • [39] Experimental study of the pressure drop in the cathode side of air-forced Open-cathode proton exchange membrane fuel cells
    Barreras, Felix
    Lopez, Ana M.
    Lozano, Antonio
    Barranco, Jose E.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (13) : 7612 - 7620
  • [40] Research on the Performance of Self-Made Open-Cathode Fuel Cell Stacks under Different Operating Conditions
    Bai, Qiang
    Liu, Zhenghong
    Hsieh, Chuangyu
    MEMBRANES, 2023, 13 (11)