Experimental study on temperature and performance of an open-cathode PEMFC stack under thermal radiation environment

被引:27
|
作者
Zhang, Jikai [1 ,2 ]
Wang, Changjian [1 ,3 ]
Zhang, Aifeng [1 ,2 ]
机构
[1] Hefei Univ Technol, Sch Civil Engn, Hefei 230009, Anhui, Peoples R China
[2] Anhui Int Joint Res Ctr Hydrogen Safety, Hefei 230009, Peoples R China
[3] Minist Educ, Engn Res Ctr Safety Crit Ind Measurement & Contro, Hefei, Peoples R China
关键词
Open-cathode PEMFC; Thermal radiation; Performance degradation; Temperature distribution; Single -cell voltage uniformity; MEMBRANE FUEL-CELL; IN-SITU MEASUREMENT; RELATIVE-HUMIDITY; BREATHING PEMFC; FLOW CHANNEL; AIR; SYSTEM; OPTIMIZATION; DESIGN; ANODE;
D O I
10.1016/j.apenergy.2022.118646
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The open-cathode proton exchange membrane fuel cell stack is an air-cooled stack, and has the characteristics of small footprint and high power density because of its unique configuration, combining oxidizer and coolant via axial fan. Depending on the demands of the application, proton exchange membrane fuel cells inevitably operate in harsh environments, such as high pressure, low or high temperature, etc. In this study, the performance of a 10-cell open-cathode PEMFC stack under thermal radiation was evaluated. The variations in cathode air temperature and relative humidity, stack temperature, output power and single-cell voltage under three different radiant heat fluxes were obtained by changing the load current and cathode air flow rate. The experimental results show that, even if the thermal radiation is beneficial to improve the stack temperature, the stack performance is not improved in all tested cases. Conversely, the degradation of stack power and failure of the stack continuous operation can be observed, especially for higher radiant heat flux, higher load current and lower air velocity. For the highest radiant heat flux in current study, the temperature of the first single cell closest to the radiant heat source exceeds the maximum allowable operating temperature of 65 degrees C due to the insufficient capacity of air cooling and the heating effect of radiant heat source. The significant drop in the first single-cell voltage results in the rapid degradation of the overall performance of the stack, and finally the stack fails to run continuously.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Thermal management of open-cathode proton exchange membrane fuel cell stack with thin vapor chambers
    Huang, Zipeng
    Jian, Qifei
    Zhao, Jing
    JOURNAL OF POWER SOURCES, 2021, 485
  • [22] Real-time thermal Management of Open-Cathode PEMFC system based on maximum efficiency control strategy
    Yin, Liangzhen
    Li, Qi
    Wang, Tianhong
    Liu, Lu
    Chen, Weirong
    ASIAN JOURNAL OF CONTROL, 2019, 21 (04) : 1796 - 1810
  • [23] Performance Improvement by Temperature Control of an Open-Cathode PEM Fuel Cell System
    Strahl, S.
    Husar, A.
    Puleston, P.
    Riera, J.
    FUEL CELLS, 2014, 14 (03) : 466 - 478
  • [24] Numerical Investigation of Water and Temperature Distributions for Open-Cathode Polymer Electrolyte Fuel Cell Stack With Edge Cooling
    Sasmito, Agus P.
    Shamim, Tariq
    Birgersson, Erik
    Mujumdar, Arun S.
    JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 2013, 10 (06):
  • [25] Performance evaluation of cathode channels with different cross-sections for open-cathode polymer electrolyte membrane fuel cell stack
    Thapa, Shikha
    Ganesh, V.
    Agarwal, Harshal
    Sahu, Akhila Kumar
    JOURNAL OF POWER SOURCES, 2024, 603
  • [26] Thermal coupling of an open-cathode proton exchange membrane fuel cell with metal hydride canisters: An experimental study
    Omrani, Reza
    Nguyen, Huy Quoc
    Shabani, Bahman
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2020, 45 (53) : 28940 - 28950
  • [27] NUMERICAL INVESTIGATION OF WATER AND TEMPERATURE DISTRIBUTIONS FOR OPEN-CATHODE POLYMER ELECTROLYTE FUEL CELL STACK WITH EDGE COOLING
    Sasmito, Agus Pulung
    Shamim, Tariq
    Birgersson, Erik
    Mujumdar, Arun Sadashiv
    PROCEEDINGS OF THE ASME 11TH FUEL CELL SCIENCE, ENGINEERING, AND TECHNOLOGY CONFERENCE, 2013, 2014,
  • [28] Experimental study on the thermal management of an open-cathode air-cooled proton exchange membrane fuel cell stack with ultra-thin metal bipolar plates
    Chang, Huawei
    Cai, Fengyang
    Yu, Xianxian
    Duan, Chen
    Chan, Siew Hwa
    Tu, Zhengkai
    ENERGY, 2023, 263
  • [29] Experimental study of dynamic performance of defective cell within a PEMFC stack
    Yu, Xingzi
    Zhang, Caizhi
    Fan, Min
    Deng, Bo
    Huang, Chengcheng
    Xu, Jiangfeng
    Liu, Deman
    Jiang, Shangfeng
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2022, 47 (13) : 8480 - 8491
  • [30] Analysis of the Performance of an Open-Cathode Polymer Electrolyte Fuel Cell Stack Using Simultaneous Electrochemical Impedance Spectroscopy Measurements
    Cruz-Manzo, Samuel
    Chen, Rui
    Greenwood, Paul
    13TH INTERNATIONAL CONFERENCE ON ADVANCED BATTERIES, ACCUMULATORS AND FUEL CELLS (ABAF 2012), 2014, 48 (01): : 47 - 58