Performance evaluation of the Inveon PET Scanner using GATE based on the NEMA NU-4 Standards

被引:0
|
作者
Lu, Lijun [1 ]
Karakatsanis, Nicolas
Ma, Jianhua [1 ]
Bian, Zhaoying [1 ]
Han, Yanjiang
Tang, Jing
Rahmim, Arman
Chen, Wufan [1 ]
机构
[1] Southern Med Univ, Sch Biomed Engn, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金; 美国国家科学基金会;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The purpose of this study is to validate the application of GATE (Geant4 Application for Tomographic Emission) Monte Carlo simulation toolkit to model the performance characteristics of Siemens Inveon small animal PET system. GATE has been utilized to accurately create a complete PET imaging system model, including system geometry, physics process, signal processing and time-dependent effects. The GATE output data were histogrammed into 3D sinograms and subsequently processed by the Software of Tomography Reconstruction (STIR) to reconstruct 3D PET images. The simulation results were validated against experimental data in accordance with the NEMA NU-4 2008 protocol for standardized evaluation of spatial resolution, sensitivity, scatter fraction (SF) and noise equivalent counting rate (NECR) of a preclinical PET system. An agreement of less than 3% was obtained between the spatial resolution of the simulated and experimental results. The simulated peak NECR of mouse-size phantom agreed with the experimental result, while for the rat-size phantom simulated value was higher than experimental result. The simulated and experimental SFs of mouse- and rat- size phantom both reach an agreement of less than 2%. Therefore, it has been shown the feasibility of our GATE model to accurately simulate, within certain limits, all major performance characteristics of Inveon PET system. In future, the validated model can be utilized to validate, assess and further develop reconstruction algorithms and PET acquisition protocols.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Performance Evaluation of the Inveon Dedicated PET Preclinical Tomograph Based on the NEMA NU-4 Standards
    Bao, Qinan
    Newport, Danny
    Chen, Mu
    Stout, David B.
    Chatziioannou, Arion F.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (03) : 401 - 408
  • [2] NEMA NU-4 Performance Evaluation of the IRIS PET/CT Preclinical Scanner
    Belcari N.
    Camarlinghi N.
    Ferretti S.
    Iozzo P.
    Panetta D.
    Salvadori P.A.
    Sportelli G.
    Del Guerra A.
    IEEE Transactions on Radiation and Plasma Medical Sciences, 2017, 1 (04): : 301 - 309
  • [3] NEMA NU-4 2008 performance evaluation of Xtrim-PET: A prototype SiPM-based preclinical scanner
    Amirrashedi, Mahsa
    Sarkar, Saeed
    Ghafarian, Pardis
    Shahraki, Reza Hashemi
    Geramifar, Parham
    Zaidi, Habib
    Ay, Mohammad Reza
    MEDICAL PHYSICS, 2019, 46 (11) : 4816 - 4825
  • [4] Performance Evaluation of a New Dedicated Breast PET Scanner Using NEMA NU4-2008 Standards
    Miyake, Kanae K.
    Matsumoto, Keiichi
    Inoue, Mika
    Nakamoto, Yuji
    Kanao, Shotaro
    Oishi, Tae
    Kawase, Shigeto
    Kitamura, Keishi
    Yamakawa, Yoshiyuki
    Akazawa, Ayako
    Kobayashi, Tetsuya
    Ohi, Junichi
    Togashi, Kaori
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (07) : 1198 - 1203
  • [5] Performance Evaluation of a PEM Scanner Using the NEMA NU 4-2008 Small Animal PET Standards
    Luo, Weidong
    Anashkin, Edward
    Matthews, Christopher G.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 94 - 103
  • [6] Performance evaluation of the small-animal PET scanner ClairvivoPET using NEMA NU 4-2008 Standards
    Sato, K.
    Shidahara, M.
    Watabe, H.
    Watanuki, S.
    Ishikawa, Y.
    Arakawa, Y.
    Nai, Y. H.
    Furumoto, S.
    Tashiro, M.
    Shoji, T.
    Yanai, K.
    Gonda, K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (02): : 696 - 711
  • [7] NEMA NU-4 performance evaluation of a non-human primate animal PET
    Chai Pei
    Feng Baotong
    Zhang Zhiming
    Tang Haohui
    Liu Shuanquan
    Sun Xiaoli
    Wang Peilin
    Wang Xiaoming
    Zhao Xudong
    Wei Long
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (10):
  • [8] Image quality assessment for several positron emitters using the NEMA NU 4 2008 standards in the Inveon small-animal PET scanner
    Disselhorst, Jonathan
    Brom, Maarten
    Laverman, Peter
    Slump, Cornelis
    Boerman, Otto
    Oyen, Wim
    Gotthardt, Martin
    Visser, Eric
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [9] Performance evaluation of the Mediso PET scanner to image three mice simultaneously based on the NEMA NU4-2008 standards
    Li, Guiyu
    Ma, Xiaowei
    Wang, Jing
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [10] Performance Evaluation of the FLEX Triumph X-PET Scanner Using the National Electrical Manufacturers Association NU-4 Standards
    Prasad, Rameshwar
    Ratib, Osman
    Zaidi, Habib
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (10) : 1608 - 1615