Performance evaluation of the Inveon PET Scanner using GATE based on the NEMA NU-4 Standards

被引:0
|
作者
Lu, Lijun [1 ]
Karakatsanis, Nicolas
Ma, Jianhua [1 ]
Bian, Zhaoying [1 ]
Han, Yanjiang
Tang, Jing
Rahmim, Arman
Chen, Wufan [1 ]
机构
[1] Southern Med Univ, Sch Biomed Engn, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金; 美国国家科学基金会;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The purpose of this study is to validate the application of GATE (Geant4 Application for Tomographic Emission) Monte Carlo simulation toolkit to model the performance characteristics of Siemens Inveon small animal PET system. GATE has been utilized to accurately create a complete PET imaging system model, including system geometry, physics process, signal processing and time-dependent effects. The GATE output data were histogrammed into 3D sinograms and subsequently processed by the Software of Tomography Reconstruction (STIR) to reconstruct 3D PET images. The simulation results were validated against experimental data in accordance with the NEMA NU-4 2008 protocol for standardized evaluation of spatial resolution, sensitivity, scatter fraction (SF) and noise equivalent counting rate (NECR) of a preclinical PET system. An agreement of less than 3% was obtained between the spatial resolution of the simulated and experimental results. The simulated peak NECR of mouse-size phantom agreed with the experimental result, while for the rat-size phantom simulated value was higher than experimental result. The simulated and experimental SFs of mouse- and rat- size phantom both reach an agreement of less than 2%. Therefore, it has been shown the feasibility of our GATE model to accurately simulate, within certain limits, all major performance characteristics of Inveon PET system. In future, the validated model can be utilized to validate, assess and further develop reconstruction algorithms and PET acquisition protocols.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Performance evaluation of a small-animal PET scanner with 213 mm axis using NEMA NU 4-2008
    Wei, Qing
    Wang, Yingjie
    Huang, Xianchao
    Li, Daowu
    Zheng, Yushuang
    Wang, Peilin
    Sun, Xiaoli
    Chai, Pei
    Han, Xiaorou
    Liu, Shuangquan
    Feng, Baotong
    Zhou, Wei
    Zeng, Xiangtao
    Zhu, Meiling
    Zhang, Zhiming
    Wei, Long
    MEDICAL PHYSICS, 2024,
  • [22] National Electrical Manufacturers Association NU-4 Performance Evaluation of the PET Component of the NanoPET/CT Preclinical PET/CT Scanner
    Szanda, Istvan
    Mackewn, Jane
    Patay, Gergely
    Major, Peter
    Sunassee, Kavitha
    Mullen, Gregory E.
    Nemeth, Gabor
    Haemisch, York
    Blower, Philip J.
    Marsden, Paul K.
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (11) : 1741 - 1747
  • [23] NEMA NU 4-2008 validation and applications of the PET-SORTEO Monte Carlo simulations platform for the geometry of the Inveon PET preclinical scanner
    Boisson, F.
    Wimberley, C. J.
    Lehnert, W.
    Zahra, D.
    Pham, T.
    Perkins, G.
    Hamze, H.
    Gregoire, M-C
    Reilhac, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (19): : 6749 - 6763
  • [24] Comparison of the Performance Evaluation of the MicroPET R4 Scanner According to NEMA Standards NU 4-2008 and NU 2-2001
    Popota, Fotini D.
    Aguiar, Pablo
    Raul Herance, J.
    Pareto, Deborah
    Rojas, Santiago
    Ros, Domenec
    Pavia, Javier
    Domingo Gispert, Juan
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 1879 - 1886
  • [25] Validation of a Monte Carlo simulation of the Inveon PET scanner using GATE
    Lu, Lijun
    Zhang, Houjin
    Bian, Zhaoying
    Ma, Jianhua
    Feng, Qiangjin
    Chen, Wufan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 828 : 170 - 175
  • [26] Performance Evaluation of a PET of 7T Bruker Micro-PET/MR Based on NEMA NU 4-2008 Standards
    Doss, Kishore Krishnagiri Manoj
    Mion, Pei En
    Kao, Yu-Chieh Jill
    Kuo, Tsung-Ter
    Chen, Jyh-Cheng
    ELECTRONICS, 2022, 11 (14)
  • [27] First Test Results of a Commercially Available Clinical PET Scanner Using the NEMA NU 4-2008 Small Animal PET Standards
    Luo, Weidong
    Anashkin, Edward
    Matthews, Chris G.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3991 - 3996
  • [28] Performance evaluation of siemens CTI ECAT EXACT 47 PET scanner using NEMA NU2-2001
    Kim, JS
    Lee, JS
    Lee, DS
    Jung, JK
    Lee, MC
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3118 - 3120
  • [29] Technical Note: Performance evaluation of a small-animal PET/CT system based on NEMA NU 4-2008 standards
    Liu, Qiong
    Li, Chaofan
    Liu, Jiguo
    Krish, Kishore
    Fu, Xinlei
    Zhao, Jie
    Chen, Jyh-Cheng
    MEDICAL PHYSICS, 2021, 48 (09) : 5272 - 5282
  • [30] NEMA NU 2-2007 performance measurements of the Siemens Inveon™ preclinical small animal PET system
    Kemp, Brad J.
    Hruska, Carrie B.
    McFarland, Aaron R.
    Lenox, Mark W.
    Lowe, Val J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (08): : 2359 - 2376