Performance evaluation of siemens CTI ECAT EXACT 47 PET scanner using NEMA NU2-2001

被引:0
|
作者
Kim, JS [1 ]
Lee, JS [1 ]
Lee, DS [1 ]
Jung, JK [1 ]
Lee, MC [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Nucl Med, Seoul, South Korea
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner was measured using NEMA NU2-2001 standard. ECAT EXACT 47 is a BGO crystal based PET scanner. Coincidence window are set to 12 ns, and energy window are set to 250 similar to 650 keV. For the spatial resolution measurement, F-18 point source was placed at 1cm and 10 cm offset from the center of transaxial FOV. Images were reconstructed using FBP with ramp filter. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by 1 similar to 5 aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity were estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 solution (2D: 2,900 MBq), and coincidence count rates were measured for 7 half-lives to obtain noise equivalent count rate (NECR) and scatter fraction. Transverse and axial resolutions at 1cm offset from the center were 9.1 and 9.8 mm (FBP, 2D and 3D), Sensitivity values were 709 (2D), 3332 (3D) cps/MBq at the center and 796(2D), 4050 (3D) cps/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D). Peak true count rate and NECR were 64.0 kcps@37.5 kBq/mL and 49.6 kcps@37.5 kBq/mL in 2D. Information about the performance of EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.
引用
收藏
页码:3118 / 3120
页数:3
相关论文
共 50 条
  • [1] NEMA NU2-2001 guided performance evaluation of four siemens ECAT PET scanners
    Herzog, H
    Tellmann, L
    Hocke, C
    Pietrzyk, U
    Casey, ME
    Kuwert, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2662 - 2669
  • [2] NEMA NU2-2001 guided performance evaluation of four siemens ECAT PET-scanners
    Herzog, H
    Tellmann, L
    Hocke, C
    Pietrzyk, U
    Casey, ME
    Kuwert, T
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2836 - 2838
  • [3] NEMA NU2-2001 performance results for the GE advance PET system
    Kohlmeyer, SG
    Stearns, CW
    Kinahan, PE
    Lewellen, TK
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 890 - 894
  • [4] The jPET-D4: Performance evaluation of four-layer DOI-PET scanner using the NEMA NU2-2001 standard
    Yoshida, Eiji
    Kobayashi, Ayako
    Yamaya, Taiga
    Watanabe, Mitsuo
    Nishikido, Fumihiko
    Kitamura, Keishi
    Hasegawa, Tomoyuki
    Fukushi, Masahiro
    Murayama, Hideo
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2532 - 2536
  • [5] impact of the lower energy threshold on the NEMA NU2-2001 count-rate performance of a LSO based PET-CT scanner
    Eckardt, J.
    Herzog, H.
    Schaefers, K. P.
    Kaepplinger, S.
    Schober, O.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2008, 47 (05): : 210 - 214
  • [6] PET performance measurements using the NEMA NU 2-2001 standard
    Daube-Witherspoon, ME
    Karp, JS
    Casey, ME
    DiFilippo, FP
    Hines, H
    Muehllehner, G
    Simcic, V
    Stearns, CW
    Adam, LE
    Kohlmyer, S
    Sossi, V
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (10) : 1398 - 1409
  • [7] NEMA NU 2-2001 performance testing of a Philips Gemini GXL PET/CT scanner
    Chithradevi Sathiakumar
    Seu Som
    Stefan Eberl
    Peter Lin
    Australasian Physical & Engineering Sciences in Medicine, 2010, 33 : 199 - 209
  • [8] NEMA NU 2-2001 performance testing of a Philips Gemini GXL PET/CT scanner
    Sathiakumar, Chithradevi
    Som, Seu
    Eberl, Stefan
    Lin, Peter
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2010, 33 (02) : 199 - 209
  • [9] Performance evaluation of a whole-body PET-CT scanner according the NEMA NU 2-2001 standard
    Tosi, G.
    Leonardi, L.
    Chiti, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S261 - S261
  • [10] PERFORMANCE EVALUATION OF THE HIGH-RESOLUTION PET SCANNER ECAT EXACT HR
    WIENHARD, K
    DAHLBOM, M
    ERIKSSON, L
    MICHEL, C
    PIETRZYK, U
    HEISS, WD
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P101 - P101